    INSTALLATION AND OPERATION MANUAL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE THIS APPLIANCE MUST BE INSTALLE D BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION. P P/N 775001M, Rev. Q, 12/03 MODEL 1500HT EPA CERTIFIED WOOD BURNING STOVE ...

  • Milwaukee 1500HT - page 2

    IMPORTANT WARNINGS CAUTION: PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FOR YOUR SAFETY, FOLLOW THE INST ALLATION, OPERATION AND MAINTENANCE INSTRUC- TIONS EXACTLY, WITHOUT DEVIATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. IF THIS APPLI ANCE IS NOT PROPER ...

  • Milwaukee 1500HT - page 3

    PAGE 3 TABLE OF CONTENTS Important Warn ings ................................................ 2 Testing/Listing, EPA, Using this Manual .................. 3 Planning Your Inst allation ..................................... 4-6 Manufactured (Mobile) Ho me Requirements ........... 6 Installati on ...................................................... ...

  • Milwaukee 1500HT - page 4

    PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturers’ in- structions. The installation of a wood burnin ...

  • Milwaukee 1500HT - page 5

    PLANNING YOUR INSTALLATION PAGE 5 COMBUSTIBLE WALL CLEARANCE WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES. There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first estab- lished for the stove itself and increased base ...

  • Milwaukee 1500HT - page 6

    PLANNING YOUR INSTALLATION PAGE 6 REDUCED MASONRY ST RUCTURE CLEARANCE (ALCOVE) Your Earth Stove can be installed in a masonry struc- ture with reduced clearances if the structure was built to National Building Code for fireplaces and chimneys (UBC 37). The firebox of the masonry structure must be of ade- quate size to allow a minimum of 6" (1 ...

  • Milwaukee 1500HT - page 7

    INSTALLATION PAGE 7 Once the outside air floor duct is in position, replace the floor protector. Make sure that the floor protector's hole is aligned with the outside air opening. Next position and align the stove on the hearth pad. Manufactured (mobile) home installations require that the stove be secured to the floor. This ens ures that the ...

  • Milwaukee 1500HT - page 8

    INSTALLATION PAGE 8 INSTALLING THE BAFFLE BRICKS There are 2 brick retainer tube assemblies located be- low the ceiling of the firebox which require baffle brick before the stove can be operated. Install the baffle brick as follows: 1. Place the first three brick onto the brick retainers with the notch facing up and toward the front. Next, slide th ...

  • Milwaukee 1500HT - page 9

    INSTALLATION PAGE 9 ACCEPTABLE CONNECTOR PIPE FOR INSTALLA- TIONS For Standard Residential Clearances: Six 6 inch (152 mm) minimum, single wall, 25 gage minimum thickness, stove pipe is acceptable. Three (3) pre-drilled holes are provided in the flue collar fo r fastening the pipe securely to the stove. Use sheet metal screws to do this. Addi- tion ...

  • Milwaukee 1500HT - page 10

    INSTALLATION PAGE 10 CHIMNEY HEIGHT REQUIREMENTS The chimney must extend 3 feet (914 mm) above the level of roof penetration and a minimum of 2 feet (610 mm) higher than any roof surface within 10 feet (305 cm) (see below). Check with your local building officials for any additional requirements for your area. Due to prevailing winds, local terrain ...

  • Milwaukee 1500HT - page 11

    INSTALLATION PAGE 11 RESIDENTIAL STANDARD Using 6” (152 mm) Diameter Single Wall Con- nector Pipe Not Approved For Manufactured (Mobile) Home MANUFACTURED (MOBILE) HOME STANDARD Using 6” (152 mm) Diameter Ty pe L-Vent Connector Pipe ...

  • Milwaukee 1500HT - page 12

    INSTALLATION Combustible Wall Chimney Connector Pass-Throughs NOTES: 1. Connectors to a masonry chimney , excepting method B, shall ext end in one continuous section through the wall pass-through syste m and the chimney wall, to but not past the inner flue liner face. 2. A chimney connector shall not pass through an attic or roof space, closet or s ...

  • Milwaukee 1500HT - page 13

    PRODUCT FEATURES AND CONTROLS CARE AND OPERATI0N PAGE 13 ASH DRAWER The large ash drawer located on the left side of the ped- estal is designed to make cleaning easier by containing the ashes in a removable drawer. CAUTION: DO NOT OPERATE THE STOVE WITH THE ASH DRAWER OPEN OR AJAR, AS THIS WILL PRODUCE EXTREME TEMPERATURES WITHIN THE STOVE (OVERFIR ...

  • Milwaukee 1500HT - page 14

    CARE AND OPERATION PAGE 14 PRIMARY AIR CONTROL This appliance is equipped with a control for the combustion air, located on the lower right si de (front) of the stove. Slid- ing the control to the right increases the burn rate, to the left decreases the burn rate. You will generally want to set the control in the low or me- dium range. The stove is ...

  • Milwaukee 1500HT - page 15

    FUEL PAGE 15 BURN RECOMMENDED FUEL This appliance is approved for use with untreated natural dry wood only (see Important Warnings , page 2, #8). Do not burn particleboard scraps or pressed logs using bond- ing agents because they can produce conditions that will deteriorate metal. Green or uncured wood does not work well as fuel, and can cause inc ...

  • Milwaukee 1500HT - page 16

    MAINTENANCE PAGE 16 SMALL AREA PAINT TOUCH-UP The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-B Stove Paint, Catalog # 70K99. Do not touch-up your stove with any other paint. Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the tou ...

  • Milwaukee 1500HT - page 17

    MAINTENANCE PAGE 17 Replacing Glass: 1. Remove door from stove by lifting door up and off hinge pins: Place the door on a flat protected (towel) clean flat surface with the inside of the door facing up. Remove the glass clips (by removing screws holding clips), then care- fully remove broken glass one piece at a time (protective gloves are recommen ...

  • Milwaukee 1500HT - page 18

    TROUBLESHOOTING PAGE 18 SMOKES OUT FUEL DOOR WHEN OPEN (see ✸ ) 1. The primary air control is closed. 2. The chimney is too cool. Set the primary air control on "HIGH" for a few minutes before opening the fuel door. 3. Excess creosote will not only re strict your draft but it will create a risk of a creosote fire. Strictly adhere to mai ...

  • Milwaukee 1500HT - page 19

    TROUBLESHOOTING PAGE 19 The following are a few conditions that should be evaluated and (corrected if necessary) if an overfiring condition is sus- pected: Overfiring Caused From Improper Installation - Ensure that all installation requirements have been met as outlined in the installation manual. The chimney should be clean and in good repair. A d ...

  • Milwaukee 1500HT - page 20

    SPECIFICATIONS: Model 1500 HT PAGE 20 Approximate heating capacity Up to ~1500 Sq. Ft. (Up to ~450 Sq. M) Outside air provision Yes Log length 20" (508 mm) Flue position Top Flue collar size 6" (152 mm) Width 27 1/2" (699 mm) Depth 24" (610 mm) Height (to flue) 30 3/4" (781 mm) Height 29 3/4" (756 mm) Stove back to flu ...

  • Milwaukee 1500HT - page 21

    REPLACEMENT PARTS LIST - Model 1500HT PAGE 21 PART NO. DESCRIPTION Door Parts G6000 Door Assembly, Cast Black 14M72 Door Assembly, Gold 27M67 Clip Set, Glass 86-128 Door Gasket Kit, 3/4" Rope (includes adhesive) 27M81 Gasket, Glass Channel (Per Foot) G2000-7 Glass, Arched 9 1/2 X 15 3/4" (glass gasket not included) 10300 Handle Assembly ( ...

  • Milwaukee 1500HT - page 22

    COMPONENT DIAGRAMS – Model 1500HT FIREBRICK Part/Catalog # Quantity Dimensions Part/Catalog # Quantity Dimensions FB-1 6 9 x 4 1/2” FB11 1 4 1/2” x 4 3/8” FB2 10 9 x 4 1/2” w/notch 10545 5 * 9 x 4 1/2” w/notch 01115 1 Grate FB-5 1 9 x 2 1/2” w/hole * Baffle brick are a special dens er brick. Do not substi- tute Note: All brick are 1 ? ...

  • Milwaukee 1500HT - page 23

    OPTIONAL ACCESSORIES – Model 1500HT Note: Install and use accessories per instructions provided with the accessory kit. PAGE 23 Catalog # Model # Description Notes 14M67 OAFD-S Outside Air Floor Duct 5 1/4" Square 14M72 DK100-G Gold Door Kit 14M22 BK-100 Blower Kit Includes Dial-A- Temp for Variable Speed Control 14M21 SSK Stove Stat Kit T h ...

  • Milwaukee 1500HT - page 24

    SAFETY/LISTING LABEL PAGE 24 ...

  • Milwaukee 1500HT - page 25

    EPA LABEL PAGE 25 ...

  • Milwaukee 1500HT - page 26

    Page 26 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

  • Milwaukee 1500HT - page 27

    1110 West Taft Avenue Orange, CA 92865 ...

Fabbricante Milwaukee Categoria Stove

I documenti che otteniamo dal fabbricante del dispositivoMilwaukee 1500HT possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Milwaukee
- manuali per l’uso 1500HT
- schede prodotto Milwaukee
- opuscoli
- o etichette energetiche Milwaukee 1500HT
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Milwaukee 1500HT.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Milwaukee 1500HT, manuali di manutenzione, brevi manuali o manuali utente Milwaukee 1500HT. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Milwaukee 1500HT.

Manuali per l’uso simili

Manuale completo del dispositivo Milwaukee 1500HT, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Milwaukee 1500HT dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Milwaukee 1500HT.

Il manuale per l’uso completo Milwaukee, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Milwaukee 1500HT - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Milwaukee 1500HT, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Milwaukee 1500HT che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Milwaukee 1500HT - che ci dovrebbe aiutare nei primi passi durante l'uso Milwaukee 1500HT
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Milwaukee 1500HT
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Milwaukee 1500HT in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Milwaukee 1500HT?

Utilizza il modulo sottostante

Se non hai risolto il problema con Milwaukee 1500HT con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Milwaukee 1500HT è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)