Milwaukee 1500HTの取扱説明書

27ページ 1.19 mb
ダウンロード

ページに移動 of 27

Summary
  • Milwaukee 1500HT - page 1

    INSTALLATION AND OPERATION MANUAL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE THIS APPLIANCE MUST BE INSTALLE D BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION. P P/N 775001M, Rev. Q, 12/03 MODEL 1500HT EPA CERTIFIED WOOD BURNING STOVE ...

  • Milwaukee 1500HT - page 2

    IMPORTANT WARNINGS CAUTION: PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FOR YOUR SAFETY, FOLLOW THE INST ALLATION, OPERATION AND MAINTENANCE INSTRUC- TIONS EXACTLY, WITHOUT DEVIATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. IF THIS APPLI ANCE IS NOT PROPER ...

  • Milwaukee 1500HT - page 3

    PAGE 3 TABLE OF CONTENTS Important Warn ings ................................................ 2 Testing/Listing, EPA, Using this Manual .................. 3 Planning Your Inst allation ..................................... 4-6 Manufactured (Mobile) Ho me Requirements ........... 6 Installati on ...................................................... ...

  • Milwaukee 1500HT - page 4

    PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturers’ in- structions. The installation of a wood burnin ...

  • Milwaukee 1500HT - page 5

    PLANNING YOUR INSTALLATION PAGE 5 COMBUSTIBLE WALL CLEARANCE WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES. There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first estab- lished for the stove itself and increased base ...

  • Milwaukee 1500HT - page 6

    PLANNING YOUR INSTALLATION PAGE 6 REDUCED MASONRY ST RUCTURE CLEARANCE (ALCOVE) Your Earth Stove can be installed in a masonry struc- ture with reduced clearances if the structure was built to National Building Code for fireplaces and chimneys (UBC 37). The firebox of the masonry structure must be of ade- quate size to allow a minimum of 6" (1 ...

  • Milwaukee 1500HT - page 7

    INSTALLATION PAGE 7 Once the outside air floor duct is in position, replace the floor protector. Make sure that the floor protector's hole is aligned with the outside air opening. Next position and align the stove on the hearth pad. Manufactured (mobile) home installations require that the stove be secured to the floor. This ens ures that the ...

  • Milwaukee 1500HT - page 8

    INSTALLATION PAGE 8 INSTALLING THE BAFFLE BRICKS There are 2 brick retainer tube assemblies located be- low the ceiling of the firebox which require baffle brick before the stove can be operated. Install the baffle brick as follows: 1. Place the first three brick onto the brick retainers with the notch facing up and toward the front. Next, slide th ...

  • Milwaukee 1500HT - page 9

    INSTALLATION PAGE 9 ACCEPTABLE CONNECTOR PIPE FOR INSTALLA- TIONS For Standard Residential Clearances: Six 6 inch (152 mm) minimum, single wall, 25 gage minimum thickness, stove pipe is acceptable. Three (3) pre-drilled holes are provided in the flue collar fo r fastening the pipe securely to the stove. Use sheet metal screws to do this. Addi- tion ...

  • Milwaukee 1500HT - page 10

    INSTALLATION PAGE 10 CHIMNEY HEIGHT REQUIREMENTS The chimney must extend 3 feet (914 mm) above the level of roof penetration and a minimum of 2 feet (610 mm) higher than any roof surface within 10 feet (305 cm) (see below). Check with your local building officials for any additional requirements for your area. Due to prevailing winds, local terrain ...

  • Milwaukee 1500HT - page 11

    INSTALLATION PAGE 11 RESIDENTIAL STANDARD Using 6” (152 mm) Diameter Single Wall Con- nector Pipe Not Approved For Manufactured (Mobile) Home MANUFACTURED (MOBILE) HOME STANDARD Using 6” (152 mm) Diameter Ty pe L-Vent Connector Pipe ...

  • Milwaukee 1500HT - page 12

    INSTALLATION Combustible Wall Chimney Connector Pass-Throughs NOTES: 1. Connectors to a masonry chimney , excepting method B, shall ext end in one continuous section through the wall pass-through syste m and the chimney wall, to but not past the inner flue liner face. 2. A chimney connector shall not pass through an attic or roof space, closet or s ...

  • Milwaukee 1500HT - page 13

    PRODUCT FEATURES AND CONTROLS CARE AND OPERATI0N PAGE 13 ASH DRAWER The large ash drawer located on the left side of the ped- estal is designed to make cleaning easier by containing the ashes in a removable drawer. CAUTION: DO NOT OPERATE THE STOVE WITH THE ASH DRAWER OPEN OR AJAR, AS THIS WILL PRODUCE EXTREME TEMPERATURES WITHIN THE STOVE (OVERFIR ...

  • Milwaukee 1500HT - page 14

    CARE AND OPERATION PAGE 14 PRIMARY AIR CONTROL This appliance is equipped with a control for the combustion air, located on the lower right si de (front) of the stove. Slid- ing the control to the right increases the burn rate, to the left decreases the burn rate. You will generally want to set the control in the low or me- dium range. The stove is ...

  • Milwaukee 1500HT - page 15

    FUEL PAGE 15 BURN RECOMMENDED FUEL This appliance is approved for use with untreated natural dry wood only (see Important Warnings , page 2, #8). Do not burn particleboard scraps or pressed logs using bond- ing agents because they can produce conditions that will deteriorate metal. Green or uncured wood does not work well as fuel, and can cause inc ...

  • Milwaukee 1500HT - page 16

    MAINTENANCE PAGE 16 SMALL AREA PAINT TOUCH-UP The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-B Stove Paint, Catalog # 70K99. Do not touch-up your stove with any other paint. Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the tou ...

  • Milwaukee 1500HT - page 17

    MAINTENANCE PAGE 17 Replacing Glass: 1. Remove door from stove by lifting door up and off hinge pins: Place the door on a flat protected (towel) clean flat surface with the inside of the door facing up. Remove the glass clips (by removing screws holding clips), then care- fully remove broken glass one piece at a time (protective gloves are recommen ...

  • Milwaukee 1500HT - page 18

    TROUBLESHOOTING PAGE 18 SMOKES OUT FUEL DOOR WHEN OPEN (see ✸ ) 1. The primary air control is closed. 2. The chimney is too cool. Set the primary air control on "HIGH" for a few minutes before opening the fuel door. 3. Excess creosote will not only re strict your draft but it will create a risk of a creosote fire. Strictly adhere to mai ...

  • Milwaukee 1500HT - page 19

    TROUBLESHOOTING PAGE 19 The following are a few conditions that should be evaluated and (corrected if necessary) if an overfiring condition is sus- pected: Overfiring Caused From Improper Installation - Ensure that all installation requirements have been met as outlined in the installation manual. The chimney should be clean and in good repair. A d ...

  • Milwaukee 1500HT - page 20

    SPECIFICATIONS: Model 1500 HT PAGE 20 Approximate heating capacity Up to ~1500 Sq. Ft. (Up to ~450 Sq. M) Outside air provision Yes Log length 20" (508 mm) Flue position Top Flue collar size 6" (152 mm) Width 27 1/2" (699 mm) Depth 24" (610 mm) Height (to flue) 30 3/4" (781 mm) Height 29 3/4" (756 mm) Stove back to flu ...

  • Milwaukee 1500HT - page 21

    REPLACEMENT PARTS LIST - Model 1500HT PAGE 21 PART NO. DESCRIPTION Door Parts G6000 Door Assembly, Cast Black 14M72 Door Assembly, Gold 27M67 Clip Set, Glass 86-128 Door Gasket Kit, 3/4" Rope (includes adhesive) 27M81 Gasket, Glass Channel (Per Foot) G2000-7 Glass, Arched 9 1/2 X 15 3/4" (glass gasket not included) 10300 Handle Assembly ( ...

  • Milwaukee 1500HT - page 22

    COMPONENT DIAGRAMS – Model 1500HT FIREBRICK Part/Catalog # Quantity Dimensions Part/Catalog # Quantity Dimensions FB-1 6 9 x 4 1/2” FB11 1 4 1/2” x 4 3/8” FB2 10 9 x 4 1/2” w/notch 10545 5 * 9 x 4 1/2” w/notch 01115 1 Grate FB-5 1 9 x 2 1/2” w/hole * Baffle brick are a special dens er brick. Do not substi- tute Note: All brick are 1 ? ...

  • Milwaukee 1500HT - page 23

    OPTIONAL ACCESSORIES – Model 1500HT Note: Install and use accessories per instructions provided with the accessory kit. PAGE 23 Catalog # Model # Description Notes 14M67 OAFD-S Outside Air Floor Duct 5 1/4" Square 14M72 DK100-G Gold Door Kit 14M22 BK-100 Blower Kit Includes Dial-A- Temp for Variable Speed Control 14M21 SSK Stove Stat Kit T h ...

  • Milwaukee 1500HT - page 24

    SAFETY/LISTING LABEL PAGE 24 ...

  • Milwaukee 1500HT - page 25

    EPA LABEL PAGE 25 ...

  • Milwaukee 1500HT - page 26

    Page 26 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

  • Milwaukee 1500HT - page 27

    1110 West Taft Avenue Orange, CA 92865 ...

メーカー Milwaukee カテゴリー Stove

Milwaukee 1500HTのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1500HTの取扱説明書
- Milwaukeeの製品カード
- パンフレット
- またはMilwaukee 1500HTの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Milwaukee 1500HTの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Milwaukee 1500HTの取り付け説明書、サービスマニュアル、簡易説明書、またはMilwaukee 1500HTのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Milwaukee 1500HTの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Milwaukee 1500HTデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMilwaukee 1500HTを使用するのを助ける技術的文書のことです。説明書は通常、全てのMilwaukee 1500HTユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Milwaukeeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Milwaukee 1500HTの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMilwaukee 1500HTの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Milwaukee 1500HTに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Milwaukee 1500HTデバイスの基本機能を使うにあたってのヒント。 Milwaukee 1500HTのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Milwaukee 1500HTに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMilwaukee 1500HTのメーカー/サービスへの連絡先に関する情報。

Milwaukee 1500HTについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMilwaukee 1500HTの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMilwaukee 1500HTで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)