Manuale per l’uso Citizen CH-432B

13 pagine 0.11 mb
Scarica

Vai alla pagina of 13

Summary
  • Citizen CH-432B - page 1

    English Español P ortuguês Deutch Italiano Français INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONIT OR MODEL CH-432B - Eng 1 - CH-432B SYSTOLIC mmHg DIASTOLIC mmHg PULSE /min P O W E R S T A R T ...

  • Citizen CH-432B - page 2

    After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it dry in the air . Hard rubbing or wash- ing in a washing machine will cause air leakage. Also, be careful not to get water into the air hose. CLEANING METHOD OF CUFF GENERAL REMARKS General Remarks on blood pressure measurement • If the cuff is to be deflated ...

  • Citizen CH-432B - page 3

    English Español P ortuguês Deutch Italiano Français • Putting on the cuff is one of the most important tasks for ensuring proper measurement of blood pressure. Wind the cuff around the arm and tighten it so that one finger may be inserted between the cuff and arm. • Do NOT measure blood pressure after bathing or drink- ing. • When you feel ...

  • Citizen CH-432B - page 4

    • When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene. Nature and frequency of maintenance: This products is designed for use over an extended period of time; however , it is generally recommended that it be inspected ...

  • Citizen CH-432B - page 5

    English Español P ortuguês Deutch Italiano Français - Eng 5 - IDENTIFICA TION OF P ARTS C H - 4 3 2 B S Y S T O L IC m m H g D IA S T O L IC m m H g P U L S E /m in POWER ST ART BT T ube socket Systolic blood pressure display section Diastolic blood pressure/ Pulse display section Cuff Cuff tube Air connector Power/Start switch Battry cover ...

  • Citizen CH-432B - page 6

    - Eng 6 - MEASUREMENTS 1. Attaching of Arm Cuff and P osture During Measurement Unfasten and open the cuff as shown in the figure. Wind the arm cuff around the left upper arm tightly so that bottom edge of the cuff is positioned about 1 – 2cm above the elbow joint. • When you will wind the cuff, please wind the cuff next to the skin of possible ...

  • Citizen CH-432B - page 7

    English Español P ortuguês Deutch Italiano Français - Eng 7 - Rest the elbow on a table so that the section of the upper arm is at the height of the heart. Relax the lower arm across the table and remain still, since movement - artifacts may falsify the measuring result. Make measurements in either a seated or reclining posture with the palm tur ...

  • Citizen CH-432B - page 8

    - Eng 8 - The pressure is automatically heightened to the level for measurement of the blood pressure based on the last-mea- sured systolic blood pressure. At the first measurement after battery replacement the pres- sure is heightened to 160mmHg. If the level of the pressure is not enough, the pressure is automatically heightened to the level for ...

  • Citizen CH-432B - page 9

    English Español P ortuguês Deutch Italiano Français - Eng 9 - SYSTOLIC mmHg DIASTOLIC mmHg PULSE /min SYSTOLIC mmHg DIASTOLIC mmHg PULSE /min When the measurement has been completed, the systolic blood pressure, the diastolic blood pressure and the pulse rate are alternately displayed and the air is discharged. The systolic blood pressure and th ...

  • Citizen CH-432B - page 10

    - Eng 10 - 3. T urn P ower OFF Press the “ POWER / ST ART ” switch to turn off. 4. Subsequent Measurement When a measurement is need again, 10 minutes, interval is necessary between measurements. 5. Automatic P ower OFF Function If the unit is left without any operation after measure- ment, an “ Automatic Power -OFF Function ” runs to turn ...

  • Citizen CH-432B - page 11

    English Español P ortuguês Deutch Italiano Français - Eng 11 - DESCRIPTION OF DISPLA Y MARKS DISPLA Y MARK CONDITION / CA USE CORRECTIVE ACTION Displayed when the blood pressure could not be measured accurately . (Some noises were detected by the movement of arm during measurement.) Displayed when the pulse rate could not be measured. Displayed ...

  • Citizen CH-432B - page 12

    - Eng 12 - SPECIFICA TIONS Model No. CH-432B Measuring Principle Oscillometric Method Measurement Localization Left Upper Arm Cuff Soft Cuff Arm Circumference Range 22.0 to 32.0cm Measurement Range Pressure 0 to 280 mmHg Pulse 40 to 180 Pulse/min. Accuracy Pressure ± 3 mmHg Pulse ± 5% of Reading Pressure Systolic blood pressure: 3 Digits Diastoli ...

  • Citizen CH-432B - page 13

    ● CITIZEN is a registered trademark of Citizen W atch Co., Japan. Consumer Electronics Division CBM Bldg. 5F , 5-68-10, Nakano, Nakano-ku, T okyo 164-0001, Japan Phone: (03)5345-7430 Fax: (03)5345-7431 E-mail: info-con@jcbm.co .jp ...

Fabbricante Citizen Categoria Blood Pressure Monitor

I documenti che otteniamo dal fabbricante del dispositivoCitizen CH-432B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Citizen
- manuali per l’uso CH-432B
- schede prodotto Citizen
- opuscoli
- o etichette energetiche Citizen CH-432B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Citizen CH-432B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Citizen CH-432B, manuali di manutenzione, brevi manuali o manuali utente Citizen CH-432B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Citizen CH-432B.

Manuali per l’uso simili

Manuale completo del dispositivo Citizen CH-432B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Citizen CH-432B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Citizen CH-432B.

Il manuale per l’uso completo Citizen, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Citizen CH-432B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Citizen CH-432B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Citizen CH-432B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Citizen CH-432B - che ci dovrebbe aiutare nei primi passi durante l'uso Citizen CH-432B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Citizen CH-432B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Citizen CH-432B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Citizen CH-432B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Citizen CH-432B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Citizen CH-432B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (1)

нургали

как можно проверить показания тонометра