    Check following components! HEM-7213-E_B_M01_120123.pdf Manufacturer OMRON HEAL THCARE Co., Ltd. 53, Kunotsubo, T erado-cho, Muko, Kyoto, 617-0002 JAP AN EU-representative OMRON HEAL THCARE EUROPE B.V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omron-healthcare.com Production facility Site de production Herstellungswerk Stabilimento di p ...

  • Omron M6W Wide Cuff - page 2

    Content s Thank you for purchasing the OMRON M6W Automatic Blood Pressure Monitor . The OMRON M6W is a compact, fully automatic blood pressure monitor , operating on the oscillometric principle.It measures your blood pressure and pulse rate simply and quickly . For comfortable controlled in fl ation without the need of pressure pre-setting or re-i ...

  • Omron M6W Wide Cuff - page 3

    1 EN Import an t Safety I nformation Consult your doctor prior to using in pregnancy or if d iagnosed with arrhyt hmia or arterios clerosis. Please read t his section carefully b efore using the unit. War ni n g : • Indicates a pot entially hazardous situation which, if not avo ided, could result in deat h or serious injury . (General Usage) • ...

  • Omron M6W Wide Cuff - page 4

    2 Impor tant Safet y Inform ation (AC Adapter Usage) • Use only the original AC adapter (optional) designed f or this unit. Use of unsupported adapters may damage and/or may be hazardous to the unit. • Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-tap. • Do not use the AC adapter if the unit or the power cord ...

  • Omron M6W Wide Cuff - page 5

    3 EN 1. Overview Main unit Display Memory button O/I ST ART ( ) button Up/Down ( ) buttons USE R ID Se lectio n Sw itch (A / B) Date/T ime setting ( ) button Air Jack Battery compartment AC adapter jack ( for optional AC adapter) Arm cuff Arm cuff (Wide Range Cuff: arm circumferenc e 22-42 cm) Marker Air tube Air plug Display Date/T ime display USE ...

  • Omron M6W Wide Cuff - page 6

    4 2. Prep aration 2.1 Inst alling/Replaci ng the Batteries 1. Remove the battery cover . 2. Insert four “AA” batteries as indicated in the battery comp artment and then replace the battery cover . Not es: • If the ba ttery low symbol ( ) appea rs on the display , turn the uni t off t hen replace all batter ies at the same time. • The me asu ...

  • Omron M6W Wide Cuff - page 7

    5 2. Prep arat ion EN 2.2 Setting the Date and T ime 1. Pres s th e butt o n. 2. Set the monitor to the correct date and time before t aking a measureme nt for the first time. 3. Press t he O/I ST ART butt on to store the setting. Not es: • If the batteries have been removed for 30 seco nds or more, the date and time setting will need to be reset ...

  • Omron M6W Wide Cuff - page 8

    6 3. Using the Unit 3.1 Appl ying the Ar m Cuff Remo ve tight- fittin g clothin g or tigh t rolled up sleev e from y our uppe r arm. Do no t place th e cuff over th ick clothe s. 1. Insert the air plug into the ai r jack . 2. Put your arm through the cuff loop . 3. Position the arm correctly . The bo ttom ed ge of the cuff should b e 1 to 2 c m abo ...

  • Omron M6W Wide Cuff - page 9

    7 3. Using the Unit EN 3.2 How to Sit Correctly T o take a m easurem ent, you n eed to b e relax ed and com fortably s eated, under comfor table room t emperatur e. No b athing, dr inking alcoh ol or caffein e, smoking, exerci sing or eating 30 minutes before taking a m easurem ent. • Sit on a chair with you r feet flat on the f loor . • Sit up ...

  • Omron M6W Wide Cuff - page 10

    8 3. Using the Unit 3.3 T a king a Re adin g Not es: • T o can cel a m easurem ent, press th e O/I ST A RT b utton t o turn the uni t of f and to rel ease the air in t he arm cuff. • Remain still wh ile t aking a meas urement. The moni tor is design ed to take measure ments and store the measureme nt valu es in the memo ry for two peop le using ...

  • Omron M6W Wide Cuff - page 11

    9 3. Using the Unit EN Dual Check System Press the O/I ST ART button, then the Dual Check System lamp lights and the unit starts detecting a device error . If the unit is accurate and functioning correctly , the Dual Check System lamp remains lit dur ing the meas uremen t. If an e rror is detected , the D ual Chec k Sy stem lam p flash es an d “E ...

  • Omron M6W Wide Cuff - page 12

    10 3. Using the Unit • Y our blood pressure monitor includes an irregular heart beat feature. Irregular hear tbeats can influence the results of t he measur ement. The irregular heartbeat algorithm automatically determines if the m easurement is usable or needs t o be repeated. If the measurement results are affected by irregular heartbeats but t ...

  • Omron M6W Wide Cuff - page 13

    11 3. Using the Unit EN 3.4 Using the Memo ry Func tion The m onitor au tomatical ly stores the res ult up to 1 00 sets for e ach user (A and B). It can al so ca lculate an avera ge readi ng based o n the m easurem ents from the last three rea dings taken within 10 min utes. I f there ar e only tw o read ings in memor y for that per iod, th e avera ...

  • Omron M6W Wide Cuff - page 14

    12 3. Using the Unit T o V iew the R eadings S tored in Memory 1. Press the button, while t he average value is dis played. The M emory nu mber appe ars for a secon d before the pul se rate is disp layed . The newe st set i s numb ered “1”. 2. Press the or button to view the readings stored in memory . : T o the older readings : T o the more re ...

  • Omron M6W Wide Cuff - page 15

    13 EN 4. T roubl eshooting and Maint enance 4.1 The Ico ns and Error Mes sages Error Display Cause Remedy Irregular heartbeats are detected. Remove the arm cuff. W ait 2-3 minutes and then t ake another measureme nt. Repeat the steps in section 3.3. If this error continues to appear , contact your doctor . Movement durin g measurement. Carefully re ...

  • Omron M6W Wide Cuff - page 16

    14 4. Troub leshoot ing and Maintena nce Note: The irregular hear tbeat symbol ( ) may also be displayed with er ror messages. Air pl ug d is con nec ted . Insert the plug securely . Refe r to section 3.1. Arm cuf f not applied correctly . Apply the arm cuff correctly . Refe r to section 3.1. Air is leaking from the arm cuf f. Repla ce the cuff wit ...

  • Omron M6W Wide Cuff - page 17

    15 4. Troub leshoot ing and Maintena nce EN 4.2 T roubleshoo ting Problem Cause Remedy The reading is extremely low (or high). Arm cuff not applied correctly . Apply the arm cuff correctly . Refer to section 3.1. Movement or talking during measurement. Remain still and do not talk during measurement. Refer to section 3.3. Clothing is interfering wi ...

  • Omron M6W Wide Cuff - page 18

    16 4. Troub leshoot ing and Maintena nce Nothing happens when you pres s the buttons. The batteries are empty . Replace the batteries with new ones. Refer to section 2.1. The batteries have been inserted incorrectly . Insert the batteries wi th the corre ct (+/ -) polarit y . Refer to section 2.1. Other problems. • Press t he O/I ST A RT button a ...

  • Omron M6W Wide Cuff - page 19

    17 4. Troub leshoot ing and Maintena nce EN 4.3 Maintenance T o protec t you r unit from damage , please o bserve the follo wing: • Do not subject the main unit and the cuf f to extreme te mperatures, humidity , moisture or direct sunlight. • Do not fold the cuff or tubing tightly . • Do not disassemble the u nit. • Do not subject the unit ...

  • Omron M6W Wide Cuff - page 20

    18 4. Troub leshoot ing and Maintena nce 4.4 St or a g e Keep th e unit i n its stor age case when no t in us e. 1. Unplug the air plu g from the air jack. 2. Gently fold the air tube into the arm cuff. Note: Do not bend t he air tube exc essively . 3. Place t he arm cuff and main unit in the storage case. Do no t store th e unit in the foll owing ...

  • Omron M6W Wide Cuff - page 21

    19 EN 5. Optional Part s Using th e Optio nal AC Adapter 1. Insert the AC a dapter plug into the AC adapter jack on the rear s ide of the main unit. 2. Plug the AC adapter into an electrical outlet. T o dis connec t the AC adapter , unplu g the AC adapter f rom th e electric al out let firs t and then remo ve the AC adapter plug fro m the m ain uni ...

  • Omron M6W Wide Cuff - page 22

    20 6. T echnical Dat a Note: Subject to technical modifi cation without prior notice. Product Description Automatic Blood Pressure Monitor Model OMRON M6W(HEM-7213-E(V)) Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure : 0 to 299 mmHg Pulse: 40 to 180/min. Accuracy Pressure: ± 3 mmHg Pulse: ± 5% of di ...

  • Omron M6W Wide Cuff - page 23

    21 6. Techni cal Data EN • This device fulfil s the p rovis ions of EC dire ctiv e 93/42 /EEC (Me dical Device Directi ve). • This blood pres sure moni tor is desig ned acc ording to the Europea n S tandard E N1060, Non - invasiv e sphygm omanom eters P art 1: Ge neral Re quiremen ts and Par t 3: Supp lementary requir ements fo r electro mechan ...

  • Omron M6W Wide Cuff - page 24

    22 6. Techni cal Data Import ant in formation regardi ng Electro Mag netic Comp atibility (EMC) With the increased num ber of e lectronic devices such as PC’s and mobile (c ellular) telephones, medical devic es in use may be suscep tible to electromagnetic interference from other dev ices. Electromagnetic interference may result in incorrect oper ...

  • Omron M6W Wide Cuff - page 25

    23 EN 7. Some Use f ul I nformation about Blood Pressure What is Blood Pressure? Blood pres sure i s a meas ure of the force of blood flowing again st the walls of t he arter ies. Arterial blood pr essure is con stantly chan ging dur ing the c ourse of the hea rt’s cycle. The hig hest pre ssure in t he cy cle is ca lled th e Systoli c Bloo d Pres ...

  • Omron M6W Wide Cuff - page 26

    24 7. Some Useful In formation a bout Bl ood Pressur e Why is it a Good Thing to me asure Blood Pressure at Home? Many fac tors s uch as ph ysic al acti vity , anxiety , or the time of day , ca n influ ence your blo od pressure . A single measur ement may not be s ufficient for an accu rate diag nosis. T hus it i s best to try and measure your blo ...

Fabbricante Omron Categoria Sphygmomanometer

I documenti che otteniamo dal fabbricante del dispositivoOmron M6W Wide Cuff possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omron
- manuali per l’uso M6W Wide Cuff
- schede prodotto Omron
- opuscoli
- o etichette energetiche Omron M6W Wide Cuff
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omron M6W Wide Cuff.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omron M6W Wide Cuff, manuali di manutenzione, brevi manuali o manuali utente Omron M6W Wide Cuff. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omron M6W Wide Cuff.

Manuali per l’uso simili

Manuale completo del dispositivo Omron M6W Wide Cuff, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omron M6W Wide Cuff dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omron M6W Wide Cuff.

Il manuale per l’uso completo Omron, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omron M6W Wide Cuff - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omron M6W Wide Cuff, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omron M6W Wide Cuff che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omron M6W Wide Cuff - che ci dovrebbe aiutare nei primi passi durante l'uso Omron M6W Wide Cuff
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omron M6W Wide Cuff
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omron M6W Wide Cuff in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omron M6W Wide Cuff?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omron M6W Wide Cuff con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omron M6W Wide Cuff è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine