Manuale per l’uso Goodmans GPH 13 H

28 pagine 0.64 mb
Scarica

Vai alla pagina of 28

Summary
  • Goodmans GPH 13 H - page 1

    • Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MAN ...

  • Goodmans GPH 13 H - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodmans GPH 13 H - page 3

    PRODUCT IDENTIFICA TION 3 GPH1324H41AB GPH1330H41AB GPH1336H41AC GPH1342H41AB GPH1348H41BB GPH1360H41BB The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“EPA”) ...

  • Goodmans GPH 13 H - page 4

    4 PRODUCT DESIGN GPH Package Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can only be connected for horizontal airflow. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible ...

  • Goodmans GPH 13 H - page 5

    PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: roof top in- stallations) ...

  • Goodmans GPH 13 H - page 6

    6 PRODUCT DESIGN ELECTRICAL DA T A (*Blower Only , Heat Mode) All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum ov ...

  • Goodmans GPH 13 H - page 7

    PRODUCT DIMENSIONS 7 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T O PENI NGS ) A 14 . 0 00 B GPH13[24-60]H41** Ch as s i s M o d el A B GP H13 24H 41* * 22 . 0 00 29 . 932 GP H13 30H 41* * 22 . 0 00 29 . 932 GP H13 36H 41* * 24 . 0 00 34 . 932 GP H13 42H 41* * 24 . 0 00 34 . 932 GP H13 48H 41* * 24 . 0 ...

  • Goodmans GPH 13 H - page 8

    P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]H41AB GPH1336H41AC (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive ...

  • Goodmans GPH 13 H - page 9

    P ACKAGE HEA T PUMP SPECIFICA TIONS 9 (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger ...

  • Goodmans GPH 13 H - page 10

    ACCESSORIES 10 P a rt Nu m b e r De s cr i p t i on O T 18- 60 A O ut door T her mosta t Ki t w /Loc kout S tat O T /EHR18-60 Em e r genc y Heat Rel ay K i t HKR E l ectr ic H eat Ki t PCCP101- 103 Roof C ur b PCP 101- 103 Dow nflow Pl enum Ki t PCP 101- 103R8 Dow nflow Pl enum Ki t w / R - 8 I ns ulati on G PCED101- 103 Dow nflow Ec onomi zer for ...

  • Goodmans GPH 13 H - page 11

    BLOWER PERFORMANCE DA T A 11 Dry Coil Data NOTES: 1. Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 2. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. 3. Data shown does not include filter pressure drop, approx. 0.08” H 2 O. 4. Reduce airflow by 2% for 208V oper ...

  • Goodmans GPH 13 H - page 12

    12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P U T B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPERAT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.08 x RI SE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodmans GPH 13 H - page 13

    13 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41* * EX PAN DE D P ER F O R M ANC E D ATA COOLIN G OP E RA TION De sign S ub c ool i ng , 1 2 ±3 °F @ t he li q ui d ac c es s f i tt ing c on nec tio n AHRI 9 5 t e st c o ndi ti ons. Des i gn Superhe a t 8 ±3 °F @ the c o mp r e s s or s uc tion a c cess fit ting c onne c t i on. O ...

  • Goodmans GPH 13 H - page 14

    14 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41** EX PAN DE D P ER FO R M ANC E D ATA COOLIN G OP E RATION De sign Subc ool i ng , 12 ±3 °F @ the l i q ui d a cces s f i tt i ng connecti o n AHRI 95 t e st c o nd i ti ons. Des i g n Supe rhea t 8 ±3 °F @ the c om pr e s s or suction acc e ss fit ting c onne ct i on. O utdoo r Am ...

  • Goodmans GPH 13 H - page 15

    15 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions . De sign S upe rhe a t 8 ± 3 °F @ th e c om pre ss o r su c ti o n a cce ss f i t ti n g co n n e ...

  • Goodmans GPH 13 H - page 16

    16 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions . De sign S upe rhe a t 8 ± 3 °F @ th e c om pre ss o r su c ti o n a cce ss f i t ti n g co n n e ...

  • Goodmans GPH 13 H - page 17

    17 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L : GP H 1336H41* * E XP A ND E D PE RF ORMA N CE DA TA C OOL IN G OP E RATION De s i gn Subc oo l i n g , 1 2 ±3 °F @ the liqui d ac c es s f i tt ing c o nnec ti on AHRI 9 5 t es t c o ndi ti o ns. Des i gn S up erhea t 8 ±3 °F @ t he c om p r e s s o r suc t i o n a cce ss fi t ti n g co n n e ...

  • Goodmans GPH 13 H - page 18

    18 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L: GP H 1336H41** E XP A ND ED PE RF ORM A N CE DA T A COOL IN G OP E RATI O N De sign Subc o ol i ng , 12±3 °F @ the l i q ui d ac c es s f it t i n g conne c tio n AHRI 9 5 t es t c o ndi tion s. Des i g n Supe r h e a t 8 ±3 °F @ t he c om pr e ss o r su c t i o n a cce ss f i t t i n g co n n ...

  • Goodmans GPH 13 H - page 19

    19 COOLING PERFORMANCE DA T A GPH1342H41** MOD EL: GP H 1342 H41** EX PAN DE D P ER F O R M ANC E D ATA CO O LI N G OP E RA T I O N De s ign S ub c oo ling , 1 2± 3 °F @ t he li qu id a c ce s s f i t t i ng c on ne ct ion A R I 9 5 t e s t con d it ion s . De s ig n S u pe rh e a t 8 ±3 °F @ t he c o mp re s s or s u ction a c ces s f i tt i n ...

  • Goodmans GPH 13 H - page 20

    20 COOLING PERFORMANCE DA T A GPH1342H41** MOD E L : GP H 1342H41** EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT I ON De sig n Subc oo l i ng , 12 ±3 ° F @ the l i q ui d ac c es s f i tt i n g c onnec ti on AHRI 95 t es t c o ndi tio ns. Des i gn S uperhea t 8 ±3 °F @ the compr e ss o r suc t i o n a cce ss f i t t i n g co n n ect ...

  • Goodmans GPH 13 H - page 21

    21 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns. Des i gn Superhea t 8 ±3 °F @ th e c om p r es s or s uc ti on a cc e ss fi ttin g conne ...

  • Goodmans GPH 13 H - page 22

    22 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns. Des i gn Superhea t 8 ±3 °F @ th e c om p r es s or s uc ti on a cc e ss fi ttin g conne ...

  • Goodmans GPH 13 H - page 23

    23 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41 * * EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT IO N D esi g n Su b co o l i n g , 12 ±3 ° F @ th e l iq u i d acc ess f itt in g co n n ec ti o n A H R I 95 t est c ond i t i o n s. D esi g n Su p er h ea t 8 ±3 ° F @ th e co m p r ess o r su c t i o n a cce ss f i t ...

  • Goodmans GPH 13 H - page 24

    24 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41** E X P A ND ED PE RF ORM A N CE DA T A C O OL I NG OP ER AT IO N D esi g n Su b co o l i n g, 12 ±3 ° F @ t h e l iq u i d ac c ess f itt in g co n n ec ti o n A H R I 95 t est c o n d i ti o n s. D es i g n Su p er h ea t 8 ±3 ° F @ t h e co m p r e ss o r su c t i o n a cc e s ...

  • Goodmans GPH 13 H - page 25

    P ACKAGE HEA T PUMP SPECIFICA TIONS 25 GPH13[24-36]H41** E X PAN D ED PE RFO R M AN CE DAT A MOD E L : G P H 1324H 41* H E AT ING OPE RA TION O utdoor Am bi e nt Te m pera tur e 65 60 55 50 47 45 40 35 30 25 20 17 1 5 1 0 5 0 - 5 -10 M B h 2 7 . 72 6 . 22 4 . 62 3 . 02 2 . 02 1 . 31 9 . 81 8 . 31 7 . 41 6 . 11 4 . 8 1 4 . 0 1 3 . 5 1 2 . 1 1 0 . 7 ...

  • Goodmans GPH 13 H - page 26

    P ACKAGE HEA T PUMP SPECIFICA TIONS 26 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatu ...

  • Goodmans GPH 13 H - page 27

    WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T. F AILU RE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH1324, 30, 42H ...

  • Goodmans GPH 13 H - page 28

    28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T. F AILU RE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH1360H41BB 2 3 ...

Fabbricante Goodmans Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoGoodmans GPH 13 H possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Goodmans
- manuali per l’uso GPH 13 H
- schede prodotto Goodmans
- opuscoli
- o etichette energetiche Goodmans GPH 13 H
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Goodmans GPH 13 H.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Goodmans GPH 13 H, manuali di manutenzione, brevi manuali o manuali utente Goodmans GPH 13 H. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Goodmans GPH 13 H.

Manuale completo del dispositivo Goodmans GPH 13 H, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Goodmans GPH 13 H dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Goodmans GPH 13 H.

Il manuale per l’uso completo Goodmans, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Goodmans GPH 13 H - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Goodmans GPH 13 H, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Goodmans GPH 13 H che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Goodmans GPH 13 H - che ci dovrebbe aiutare nei primi passi durante l'uso Goodmans GPH 13 H
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Goodmans GPH 13 H
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Goodmans GPH 13 H in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Goodmans GPH 13 H?

Utilizza il modulo sottostante

Se non hai risolto il problema con Goodmans GPH 13 H con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Goodmans GPH 13 H è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)