Manual Goodmans GPH 13 H

28 pages 0.64 mb
Download

Go to site of 28

Summary
  • Goodmans GPH 13 H - page 1

    • Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MAN ...

  • Goodmans GPH 13 H - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodmans GPH 13 H - page 3

    PRODUCT IDENTIFICA TION 3 GPH1324H41AB GPH1330H41AB GPH1336H41AC GPH1342H41AB GPH1348H41BB GPH1360H41BB The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“EPA”) ...

  • Goodmans GPH 13 H - page 4

    4 PRODUCT DESIGN GPH Package Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can only be connected for horizontal airflow. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible ...

  • Goodmans GPH 13 H - page 5

    PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: roof top in- stallations) ...

  • Goodmans GPH 13 H - page 6

    6 PRODUCT DESIGN ELECTRICAL DA T A (*Blower Only , Heat Mode) All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum ov ...

  • Goodmans GPH 13 H - page 7

    PRODUCT DIMENSIONS 7 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T O PENI NGS ) A 14 . 0 00 B GPH13[24-60]H41** Ch as s i s M o d el A B GP H13 24H 41* * 22 . 0 00 29 . 932 GP H13 30H 41* * 22 . 0 00 29 . 932 GP H13 36H 41* * 24 . 0 00 34 . 932 GP H13 42H 41* * 24 . 0 00 34 . 932 GP H13 48H 41* * 24 . 0 ...

  • Goodmans GPH 13 H - page 8

    P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]H41AB GPH1336H41AC (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive ...

  • Goodmans GPH 13 H - page 9

    P ACKAGE HEA T PUMP SPECIFICA TIONS 9 (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger ...

  • Goodmans GPH 13 H - page 10

    ACCESSORIES 10 P a rt Nu m b e r De s cr i p t i on O T 18- 60 A O ut door T her mosta t Ki t w /Loc kout S tat O T /EHR18-60 Em e r genc y Heat Rel ay K i t HKR E l ectr ic H eat Ki t PCCP101- 103 Roof C ur b PCP 101- 103 Dow nflow Pl enum Ki t PCP 101- 103R8 Dow nflow Pl enum Ki t w / R - 8 I ns ulati on G PCED101- 103 Dow nflow Ec onomi zer for ...

  • Goodmans GPH 13 H - page 11

    BLOWER PERFORMANCE DA T A 11 Dry Coil Data NOTES: 1. Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 2. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. 3. Data shown does not include filter pressure drop, approx. 0.08” H 2 O. 4. Reduce airflow by 2% for 208V oper ...

  • Goodmans GPH 13 H - page 12

    12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P U T B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPERAT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.08 x RI SE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodmans GPH 13 H - page 13

    13 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41* * EX PAN DE D P ER F O R M ANC E D ATA COOLIN G OP E RA TION De sign S ub c ool i ng , 1 2 ±3 °F @ t he li q ui d ac c es s f i tt ing c on nec tio n AHRI 9 5 t e st c o ndi ti ons. Des i gn Superhe a t 8 ±3 °F @ the c o mp r e s s or s uc tion a c cess fit ting c onne c t i on. O ...

  • Goodmans GPH 13 H - page 14

    14 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41** EX PAN DE D P ER FO R M ANC E D ATA COOLIN G OP E RATION De sign Subc ool i ng , 12 ±3 °F @ the l i q ui d a cces s f i tt i ng connecti o n AHRI 95 t e st c o nd i ti ons. Des i g n Supe rhea t 8 ±3 °F @ the c om pr e s s or suction acc e ss fit ting c onne ct i on. O utdoo r Am ...

  • Goodmans GPH 13 H - page 15

    15 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions . De sign S upe rhe a t 8 ± 3 °F @ th e c om pre ss o r su c ti o n a cce ss f i t ti n g co n n e ...

  • Goodmans GPH 13 H - page 16

    16 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions . De sign S upe rhe a t 8 ± 3 °F @ th e c om pre ss o r su c ti o n a cce ss f i t ti n g co n n e ...

  • Goodmans GPH 13 H - page 17

    17 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L : GP H 1336H41* * E XP A ND E D PE RF ORMA N CE DA TA C OOL IN G OP E RATION De s i gn Subc oo l i n g , 1 2 ±3 °F @ the liqui d ac c es s f i tt ing c o nnec ti on AHRI 9 5 t es t c o ndi ti o ns. Des i gn S up erhea t 8 ±3 °F @ t he c om p r e s s o r suc t i o n a cce ss fi t ti n g co n n e ...

  • Goodmans GPH 13 H - page 18

    18 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L: GP H 1336H41** E XP A ND ED PE RF ORM A N CE DA T A COOL IN G OP E RATI O N De sign Subc o ol i ng , 12±3 °F @ the l i q ui d ac c es s f it t i n g conne c tio n AHRI 9 5 t es t c o ndi tion s. Des i g n Supe r h e a t 8 ±3 °F @ t he c om pr e ss o r su c t i o n a cce ss f i t t i n g co n n ...

  • Goodmans GPH 13 H - page 19

    19 COOLING PERFORMANCE DA T A GPH1342H41** MOD EL: GP H 1342 H41** EX PAN DE D P ER F O R M ANC E D ATA CO O LI N G OP E RA T I O N De s ign S ub c oo ling , 1 2± 3 °F @ t he li qu id a c ce s s f i t t i ng c on ne ct ion A R I 9 5 t e s t con d it ion s . De s ig n S u pe rh e a t 8 ±3 °F @ t he c o mp re s s or s u ction a c ces s f i tt i n ...

  • Goodmans GPH 13 H - page 20

    20 COOLING PERFORMANCE DA T A GPH1342H41** MOD E L : GP H 1342H41** EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT I ON De sig n Subc oo l i ng , 12 ±3 ° F @ the l i q ui d ac c es s f i tt i n g c onnec ti on AHRI 95 t es t c o ndi tio ns. Des i gn S uperhea t 8 ±3 °F @ the compr e ss o r suc t i o n a cce ss f i t t i n g co n n ect ...

  • Goodmans GPH 13 H - page 21

    21 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns. Des i gn Superhea t 8 ±3 °F @ th e c om p r es s or s uc ti on a cc e ss fi ttin g conne ...

  • Goodmans GPH 13 H - page 22

    22 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns. Des i gn Superhea t 8 ±3 °F @ th e c om p r es s or s uc ti on a cc e ss fi ttin g conne ...

  • Goodmans GPH 13 H - page 23

    23 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41 * * EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT IO N D esi g n Su b co o l i n g , 12 ±3 ° F @ th e l iq u i d acc ess f itt in g co n n ec ti o n A H R I 95 t est c ond i t i o n s. D esi g n Su p er h ea t 8 ±3 ° F @ th e co m p r ess o r su c t i o n a cce ss f i t ...

  • Goodmans GPH 13 H - page 24

    24 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41** E X P A ND ED PE RF ORM A N CE DA T A C O OL I NG OP ER AT IO N D esi g n Su b co o l i n g, 12 ±3 ° F @ t h e l iq u i d ac c ess f itt in g co n n ec ti o n A H R I 95 t est c o n d i ti o n s. D es i g n Su p er h ea t 8 ±3 ° F @ t h e co m p r e ss o r su c t i o n a cc e s ...

  • Goodmans GPH 13 H - page 25

    P ACKAGE HEA T PUMP SPECIFICA TIONS 25 GPH13[24-36]H41** E X PAN D ED PE RFO R M AN CE DAT A MOD E L : G P H 1324H 41* H E AT ING OPE RA TION O utdoor Am bi e nt Te m pera tur e 65 60 55 50 47 45 40 35 30 25 20 17 1 5 1 0 5 0 - 5 -10 M B h 2 7 . 72 6 . 22 4 . 62 3 . 02 2 . 02 1 . 31 9 . 81 8 . 31 7 . 41 6 . 11 4 . 8 1 4 . 0 1 3 . 5 1 2 . 1 1 0 . 7 ...

  • Goodmans GPH 13 H - page 26

    P ACKAGE HEA T PUMP SPECIFICA TIONS 26 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatu ...

  • Goodmans GPH 13 H - page 27

    WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T. F AILU RE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH1324, 30, 42H ...

  • Goodmans GPH 13 H - page 28

    28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T. F AILU RE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. GPH1360H41BB 2 3 ...

Manufacturer Goodmans Category Heat Pump

Documents that we receive from a manufacturer of a Goodmans GPH 13 H can be divided into several groups. They are, among others:
- Goodmans technical drawings
- GPH 13 H manuals
- Goodmans product data sheets
- information booklets
- or energy labels Goodmans GPH 13 H
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodmans GPH 13 H.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodmans GPH 13 H, service manual, brief instructions and user manuals Goodmans GPH 13 H. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodmans GPH 13 H.

A complete manual for the device Goodmans GPH 13 H, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodmans GPH 13 H by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodmans GPH 13 H.

A complete Goodmans manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodmans GPH 13 H - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodmans GPH 13 H, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodmans GPH 13 H, that we can find in the current document
3. Tips how to use the basic functions of the device Goodmans GPH 13 H - which should help us in our first steps of using Goodmans GPH 13 H
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodmans GPH 13 H
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodmans GPH 13 H in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodmans GPH 13 H?

Use the form below

If you did not solve your problem by using a manual Goodmans GPH 13 H, ask a question using the form below. If a user had a similar problem with Goodmans GPH 13 H it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)