Manuale per l’uso Emerson Process Management 3500 Transmitter

12 pagine 0.32 mb
Scarica

Vai alla pagina of 12

Summary
  • Emerson Process Management 3500 Transmitter - page 1

    Micro Motion TM Model 3500 T ransmitter (9-wire) or Model 3300 P eripheral Inst allation Inst ructi ons f or Rac k-Mount Quick Refer ence Guide P/N 3300 995, Rev . C Apr il 2003 For online t echnical sup por t, use the EXPER T 2 ™ sys tem at www .ex per t2.com. T o speak to a customer service representati v e, call t he support center ne arest y ...

  • Emerson Process Management 3500 Transmitter - page 2

    1 BEFORE YOU BEGIN This qui ck ref erence gui de e xplains basic install ation guideli nes for mounting the Micr o Motion ® Mode l 3300 /3500 a pplicati ons plat form i n a 19-inch (486,2 mm) rac k. For info rmat ion on I .S. a pplic ation s, re fer to M icro Motio n A T EX, U L, or CSA inst alla tion inst ruction s. F or complet e instruc tions a ...

  • Emerson Process Management 3500 Transmitter - page 3

    2 Europ ean instal lations This Mi cro Motion p roduct compl ies with all a pplicabl e European direc tives when p rope rly i nstal led in acco rdan ce wi th the inst ructi ons in this q uick r efe rence guide . Re fer to t he EC decla rat ion of confo rmit y for direc tives that ap ply to this prod uct. The EC decl aration o f conf ormity , wit h ...

  • Emerson Process Management 3500 Transmitter - page 4

    3 Figure 1 . Space requ irement s for prop er vent ilatio n Dimensions The Model 330 0/3500 h as the follo wing di mension s (see Fig ure 2, page 4): • Height: 128 mm (3 U or 3 HE) • W idt h: 142 mm (28 HP or 28 TE) • Depth: 16 0 mm The Model 330 0/3500 c onforms to DIN stan dard 41494, P art 5 (IEC 297- 3) for 19- inch (486,2 mm) racks . Up ...

  • Emerson Process Management 3500 Transmitter - page 5

    4 Figure 2 . Dimensions for moun ting in r ack Flowmeter cabl e lengths Maximum cable length fr om the s ensor to t he Model 3500 trans mitter i s 1000 feet (300 meter s). If you ar e insta lling the Model 330 0 applica tions per ipher al in comb inat ion w ith a tr ans mitte r , the ma xim um cab le le ngth f rom t he transmi tter’ s freque nc y ...

  • Emerson Process Management 3500 Transmitter - page 6

    5 STEP 2. Instal ling g uide rail s and wir ing co nnectors Guide rai ls Positi ons of g uide r ails and wi ring conne ctors are indi cated in Figure 3, page 6. Centers o f guide ra ils s hould be 27 HP (27 TE) a part, for exa mple, at 1 HP (TE) and 28 HP (TE). Wiring co nnectors The a pplic atio ns pl atform is sh ippe d with a so lder-tail or scr ...

  • Emerson Process Management 3500 Transmitter - page 7

    6 Figure 3 . Positi ons of g uide rail s and wir ing connec tors STEP 3. Instal ling the Mod el 3300/ 3500 in the ra ck 1. Align th e Model 33 00/3500 with the gui de ra ils. 2. Slide t he Model 3 300/3500 in to the rack. Make sure t he pin s on the back pane l mak e conta ct with t he wiring c onnectors . 3. T ight en the supplied capti ve scre ws ...

  • Emerson Process Management 3500 Transmitter - page 8

    7 STEP 4. Connecti ng input an d output wiring Connect i nput an d output wir ing to t he appropri ate ter minals on the input/ output wir ing conn ector , which is t he far right con nector . Refer to T able 1 and to t he car d that is inser ted in to the sl ee v e on the top pan el (shown in F igure 4). • Use 24 to 1 6 A WG (0,25 to 1,5 mm 2 ) ...

  • Emerson Process Management 3500 Transmitter - page 9

    8 1. Identi fy the components s ho wn in Figure 5. Figure 5 . Sensor ca ble to Model 3500 2. Prepare the ca ble accor ding t o the in structi ons in Micro Mot ion’ s 9-W ir e Flowmeter Cabl e Pr eparation and Inst allati on Guide . 3. Ensure t hat th e cable ha s 360° s hielding , conti nuous from t he transmi tter to the sensor ’ s junctio n ...

  • Emerson Process Management 3500 Transmitter - page 10

    9 5. At the t ransmit ter: a. Con nect t he col or- coded wi res to the appro priat e termi nals. T o identi fy the termin als, ref er to Figur e 5, pag e 8. No bar e wires should r emain e xposed. b . If usi ng shie lded or ar mored ca ble, co nnect the cable b raid to t he rear st ud, as d escri bed in Micro Moti on’ s 9-W ire Flow meter Cable ...

  • Emerson Process Management 3500 Transmitter - page 11

    10 Figure 6 . Power suppl y wiri ng terminal s P ower supply wiring term inals T e rmi nal designa tions for AC power T e rmi nal designa tions for DC power ...

  • Emerson Process Management 3500 Transmitter - page 12

    Micro Motion TM Micro M otion E urope Emerson Process Mana gement Wiltonstraat 30 3905 KW V eenend aal The Netherlands T +31 (0) 318 495 670 F +31 (0) 318 495 689 Micr o Motion U nit ed Kingdom Emerson Process Mana gement Limited Horsfield W a y Bredbury I ndustrial Estate Stockpor t SK6 2SU U .K. T 0800 966 180 F 0800 966 181 Micro Mo tion Japan E ...

Fabbricante Emerson Process Management Categoria Satellite Radio

I documenti che otteniamo dal fabbricante del dispositivoEmerson Process Management 3500 Transmitter possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Emerson Process Management
- manuali per l’uso 3500 Transmitter
- schede prodotto Emerson Process Management
- opuscoli
- o etichette energetiche Emerson Process Management 3500 Transmitter
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Emerson Process Management 3500 Transmitter.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Emerson Process Management 3500 Transmitter, manuali di manutenzione, brevi manuali o manuali utente Emerson Process Management 3500 Transmitter. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Emerson Process Management 3500 Transmitter.

Manuale completo del dispositivo Emerson Process Management 3500 Transmitter, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Emerson Process Management 3500 Transmitter dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Emerson Process Management 3500 Transmitter.

Il manuale per l’uso completo Emerson Process Management, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Emerson Process Management 3500 Transmitter - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Emerson Process Management 3500 Transmitter, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Emerson Process Management 3500 Transmitter che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Emerson Process Management 3500 Transmitter - che ci dovrebbe aiutare nei primi passi durante l'uso Emerson Process Management 3500 Transmitter
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Emerson Process Management 3500 Transmitter
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Emerson Process Management 3500 Transmitter in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Emerson Process Management 3500 Transmitter?

Utilizza il modulo sottostante

Se non hai risolto il problema con Emerson Process Management 3500 Transmitter con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Emerson Process Management 3500 Transmitter è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)