  • Emerson Process Management 3500 Transmitter - page 1

    Micro Motion TM Model 3500 T ransmitter (9-wire) or Model 3300 P eripheral Inst allation Inst ructi ons f or Rac k-Mount Quick Refer ence Guide P/N 3300 995, Rev . C Apr il 2003 For online t echnical sup por t, use the EXPER T 2 ™ sys tem at www .ex per t2.com. T o speak to a customer service representati v e, call t he support center ne arest y ...

  • Emerson Process Management 3500 Transmitter - page 2

    1 BEFORE YOU BEGIN This qui ck ref erence gui de e xplains basic install ation guideli nes for mounting the Micr o Motion ® Mode l 3300 /3500 a pplicati ons plat form i n a 19-inch (486,2 mm) rac k. For info rmat ion on I .S. a pplic ation s, re fer to M icro Motio n A T EX, U L, or CSA inst alla tion inst ruction s. F or complet e instruc tions a ...

  • Emerson Process Management 3500 Transmitter - page 3

    2 Europ ean instal lations This Mi cro Motion p roduct compl ies with all a pplicabl e European direc tives when p rope rly i nstal led in acco rdan ce wi th the inst ructi ons in this q uick r efe rence guide . Re fer to t he EC decla rat ion of confo rmit y for direc tives that ap ply to this prod uct. The EC decl aration o f conf ormity , wit h ...

  • Emerson Process Management 3500 Transmitter - page 4

    3 Figure 1 . Space requ irement s for prop er vent ilatio n Dimensions The Model 330 0/3500 h as the follo wing di mension s (see Fig ure 2, page 4): • Height: 128 mm (3 U or 3 HE) • W idt h: 142 mm (28 HP or 28 TE) • Depth: 16 0 mm The Model 330 0/3500 c onforms to DIN stan dard 41494, P art 5 (IEC 297- 3) for 19- inch (486,2 mm) racks . Up ...

  • Emerson Process Management 3500 Transmitter - page 5

    4 Figure 2 . Dimensions for moun ting in r ack Flowmeter cabl e lengths Maximum cable length fr om the s ensor to t he Model 3500 trans mitter i s 1000 feet (300 meter s). If you ar e insta lling the Model 330 0 applica tions per ipher al in comb inat ion w ith a tr ans mitte r , the ma xim um cab le le ngth f rom t he transmi tter’ s freque nc y ...

  • Emerson Process Management 3500 Transmitter - page 6

    5 STEP 2. Instal ling g uide rail s and wir ing co nnectors Guide rai ls Positi ons of g uide r ails and wi ring conne ctors are indi cated in Figure 3, page 6. Centers o f guide ra ils s hould be 27 HP (27 TE) a part, for exa mple, at 1 HP (TE) and 28 HP (TE). Wiring co nnectors The a pplic atio ns pl atform is sh ippe d with a so lder-tail or scr ...

  • Emerson Process Management 3500 Transmitter - page 7

    6 Figure 3 . Positi ons of g uide rail s and wir ing connec tors STEP 3. Instal ling the Mod el 3300/ 3500 in the ra ck 1. Align th e Model 33 00/3500 with the gui de ra ils. 2. Slide t he Model 3 300/3500 in to the rack. Make sure t he pin s on the back pane l mak e conta ct with t he wiring c onnectors . 3. T ight en the supplied capti ve scre ws ...

  • Emerson Process Management 3500 Transmitter - page 8

    7 STEP 4. Connecti ng input an d output wiring Connect i nput an d output wir ing to t he appropri ate ter minals on the input/ output wir ing conn ector , which is t he far right con nector . Refer to T able 1 and to t he car d that is inser ted in to the sl ee v e on the top pan el (shown in F igure 4). • Use 24 to 1 6 A WG (0,25 to 1,5 mm 2 ) ...

  • Emerson Process Management 3500 Transmitter - page 9

    8 1. Identi fy the components s ho wn in Figure 5. Figure 5 . Sensor ca ble to Model 3500 2. Prepare the ca ble accor ding t o the in structi ons in Micro Mot ion’ s 9-W ir e Flowmeter Cabl e Pr eparation and Inst allati on Guide . 3. Ensure t hat th e cable ha s 360° s hielding , conti nuous from t he transmi tter to the sensor ’ s junctio n ...

  • Emerson Process Management 3500 Transmitter - page 10

    9 5. At the t ransmit ter: a. Con nect t he col or- coded wi res to the appro priat e termi nals. T o identi fy the termin als, ref er to Figur e 5, pag e 8. No bar e wires should r emain e xposed. b . If usi ng shie lded or ar mored ca ble, co nnect the cable b raid to t he rear st ud, as d escri bed in Micro Moti on’ s 9-W ire Flow meter Cable ...

  • Emerson Process Management 3500 Transmitter - page 11

    10 Figure 6 . Power suppl y wiri ng terminal s P ower supply wiring term inals T e rmi nal designa tions for AC power T e rmi nal designa tions for DC power ...

  • Emerson Process Management 3500 Transmitter - page 12

    Micro Motion TM Micro M otion E urope Emerson Process Mana gement Wiltonstraat 30 3905 KW V eenend aal The Netherlands T +31 (0) 318 495 670 F +31 (0) 318 495 689 Micr o Motion U nit ed Kingdom Emerson Process Mana gement Limited Horsfield W a y Bredbury I ndustrial Estate Stockpor t SK6 2SU U .K. T 0800 966 180 F 0800 966 181 Micro Mo tion Japan E ...

Manufacturer Emerson Process Management Category Satellite Radio

Documents that we receive from a manufacturer of a Emerson Process Management 3500 Transmitter can be divided into several groups. They are, among others:
- Emerson Process Management technical drawings
- 3500 Transmitter manuals
- Emerson Process Management product data sheets
- information booklets
- or energy labels Emerson Process Management 3500 Transmitter
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson Process Management 3500 Transmitter.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson Process Management 3500 Transmitter, service manual, brief instructions and user manuals Emerson Process Management 3500 Transmitter. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson Process Management 3500 Transmitter.

A complete manual for the device Emerson Process Management 3500 Transmitter, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson Process Management 3500 Transmitter by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson Process Management 3500 Transmitter.

A complete Emerson Process Management manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson Process Management 3500 Transmitter - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson Process Management 3500 Transmitter, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson Process Management 3500 Transmitter, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson Process Management 3500 Transmitter - which should help us in our first steps of using Emerson Process Management 3500 Transmitter
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson Process Management 3500 Transmitter
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson Process Management 3500 Transmitter in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson Process Management 3500 Transmitter?

Use the form below

If you did not solve your problem by using a manual Emerson Process Management 3500 Transmitter, ask a question using the form below. If a user had a similar problem with Emerson Process Management 3500 Transmitter it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)