York CH060の取扱説明書

28ページ 3.48 mb
ダウンロード

ページに移動 of 28

Summary
  • York CH060 - page 1

    FOR DI STRIB UTION USE ONL Y - NO T TO BE USED A T POINT O F RETA IL SAL E 036-2 1217-001- B-1203 ® MODELS : CH060 - 5-10 TON S HORIZONT AL MODELS : CU0 60 - 300 5 -25 T ONS VERTICAL SINGL E P ACKAGE AIR CONDITIO NING W A T ER C OOLED ...

  • York CH060 - page 2

    036-2 1217-001- B-1203 2 Uni ta ry Prod ucts G roup TABLE OF CO NTENTS DE SCR IPTI ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 AP PLIC ATIO N F LEX IBI LITY . . . . . . . . . . . . . . . . . . . . . . . 3 CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REFRIGERATION CIRCUITS . . ...

  • York CH060 - page 3

    036-21 217-001- B-1203 Uni ta ry Prod ucts G roup 3 DESCRIPTION These uni ts are compl etely assembl ed, pipe d, wired, char ged and t ested at the fact ory and are s hipped ready for immed iate inst allat ion. Only the po wer supply wi ring, the ther mostat wi r - ing, t he condense r water pipin g, the condensat e drain pipi ng and t he duc twork ...

  • York CH060 - page 4

    036-2 1217-001- B-1203 4 Uni ta ry Prod ucts G roup NOTE: Cooli ng performance is ra ted at 80 ∞ F dry bul b 67 ∞ F wet bulb enter ing a ir temper ature, CFM liste d, 85 ∞ F entering 95 ∞ F leavin g wat er temperat ure, and wate r f l ow rate list ed. Gross c apaci ty does not incl ude the effe ct of evapora - tor f an m o tor heat . T ABL ...

  • York CH060 - page 5

    036-21 217-001- B-1203 Uni ta ry Prod ucts G roup 5 NOTE: Cooli ng performance is ra ted at 80 ∞ F dry bul b 67 ∞ F wet bulb enter ing a ir temper ature, CFM liste d, 85 ∞ F entering 95 ∞ F leaving wat er temperat ure, and wate r f l ow rate list ed. Gross c apaci ty does not incl ude the effe ct of evapora - tor f an m o tor heat . T ABL E ...

  • York CH060 - page 6

    036-2 1217-001- B-1203 6 Uni ta ry Prod ucts G roup NOTE: Cooli ng performance is ra ted at 80 ∞ F dry bul b 67 ∞ F wet bulb enter ing a ir temper ature, CFM liste d, 85 ∞ F entering 95 ∞ F leavin g wat er temperat ure, and wate r f l ow rate list ed. Gross c apaci ty does not incl ude the effe ct of evapora - tor f an m o tor heat . T ABL ...

  • York CH060 - page 7

    036-21 217-001- B-1203 Uni ta ry Prod ucts G roup 7 T ABL E 4: SUPPLY AIR BLOW E R PE RFO R MANCE CH060-120, 5 TO 10 T O N HO RIZO NTAL MODELS EXTERNAL STATIC PRESSURE - Inches W.C. MODEL SUPPLY 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 # C FM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1800 846 0.41 936 0.48 1024 0.56 1107 0. ...

  • York CH060 - page 8

    036-2 1217-001- B-1203 8 Uni ta ry Prod ucts G roup NOTE: At high er evapor ator airflows and wet bul b conditions , condensat e carry-over may occu r . Adj ust airflow downwar d as necessar y V al ues include pr essure drop from we t coil and clea n filters. Shaded a reas indi cate oversiz e motors. NOTE: At high er evapor ator airflows and wet bu ...

  • York CH060 - page 9

    036-21 217-001- B-1203 Uni ta ry Prod ucts G roup 9 T ABLE 7: WATERSIDE PRESSURE DROP - CU MODELS ...

  • York CH060 - page 10

    036-2 1217-001- B-1203 10 Uni ta ry Prod ucts G roup T ABLE 8: WATER PRESSURE DROP DATA - CH MO DELS ...

  • York CH060 - page 11

    036-21 217-001- B-1203 Uni ta ry Prod ucts G roup 11 T ABL E 9: COOLING PERFORMANCE DA T A - CH 5-10 T O N HORIZONT AL MODELS CH060 5 TO N 2000 C F M 9 GPM 15 GPM EWT EW T 65 ∞ F 85 ∞ F 105 ∞ F 65 ∞ F 85 ∞ F 10 5 ∞ F EW B ED B TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62 ∞ F 75 ∞ F 63.2 48.3 2.88 59.7 54.5 3.66 55.1 44.0 ...

  • York CH060 - page 12

    036-2 1217-001- B-1203 12 Uni ta ry Prod ucts G roup T ABL E 10: COOLING PERFORMANCE DA T A - CU 5-20 T ON VERTICAL MODEL S CU060 5 TON 2000 C F M 9 GPM 15 GPM EWT EW T 65 ∞ F 85 ∞ F 105 ∞ F 65 ∞ F 85 ∞ F 10 5 ∞ F EW B ED B TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW TC SC kW 62 ∞ F 75 ∞ F 62.1 48.9 2.87 58.3 47.2 3.65 54.4 45.4 4. ...

  • York CH060 - page 13

    036-21 217-001- B-1203 Uni ta ry Prod ucts G roup 13 T ABL E 1 1: COOLING P ERFORMANCE DATA - CU 300 2 5 TON VERTICA L MODELS T ABL E 12: WATER-SIDE ECONOMIZER COO L ING PERFORM ANCE DAT A - CH 5-10 TON MODELS UNIT Air @ 80 O F EDB, 67 O F EWB Wa te r Cap acity [ MBH] CFM PD [in WG] Flow [GPM] PD [PSI] EWT [ O F] To t a l Se nsib le CH060 2000 0.16 ...

  • York CH060 - page 14

    036-2 1217-001- B-1203 14 Uni ta ry Prod ucts G roup T ABL E 14: STANDARD MOTORS CH 5-10 T O N MODEL S NOT E: Single Phas e CH060 lo cated in 1- 5 ton data. T ABL E 15: ST ANDARD M OTO RS CU 5-20 TON MODELS NOTE: Single Phase unit found in small er cabinet dat a 1-5 ton. T ABL E 16: STANDARD EV APO RATOR MOTORS - CU300 - 25 TON MOD E L V O L TAG E ...

  • York CH060 - page 15

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 15 FIGURE 1 - DIMENSIONAL DATA - C H 5 T O N HORIZONTAL MODEL FIGURE 2 - DIMENSIONAL DATA - C H 8 & 10 T ON HORIZONT AL MODELS ...

  • York CH060 - page 16

    036-2 1217-001-B-1 203 16 Uni ta ry Prod ucts G roup FIGURE 3 - PHYSICAL CON FIGURATION DATA - CH 8 & 10 TON WATER S IDE ECONOM I ZER Economizer Coil Filter Frame Electrical Connections 10 12 Water Side View 2-3/4 6-1/2 Water Out Condensate ...

  • York CH060 - page 17

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 17 T ABL E 17: DIMENSIONAL DAT A - CU 5, 8 , AND 10 TON VERTICAL MODELS FIGURE 4 - DIMENSIONAL DATA - C U 5, 8 , AND 10 TON VERTICAL MODELS W A TER OUT W A TER IN CONDENSA TE DRAIN COMPRESSOR/CONDENSER ACCESS G C F 0.63" A B E ELECTRICAL PA N E L FA N M O TO R ACCESS FIL TER ACCESS COIL FIL TER ...

  • York CH060 - page 18

    036-2 1217-001-B-1 203 18 Uni ta ry Prod ucts G roup FIGURE 5 - DIMENSIONAL DATA - C U 15 T O N V ERT I CAL M ODEL 16.50" 12.25" 20.50" 2.63" 15.88 12.25" SUPPL Y AIR F AN MOT OR ACCESS FIL TER ACCESS COIL RETURN AIR DRAIN P AN FIL TER CONDENSA TE DRAIN CONDENSA TE DRAIN W A TER OUT W A TER IN COMPRESSOR/CONDENSER ACCESS OP ...

  • York CH060 - page 19

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 19 FIGURE 6 - DIMENSIONAL DATA - C U 20 TON V ERT I CAL MOD E L ...

  • York CH060 - page 20

    036-2 1217-001-B-1 203 20 Uni ta ry Prod ucts G roup FIGURE 7 - DIMENSIONAL DATA - C U 25 T O N V ERT I CAL M ODEL ...

  • York CH060 - page 21

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 21 SUPPLY AIR/RET URN AIR CONFIGURATION All mode ls ar e field c onvertib le for multiple supply re turn con - figura tions. The 5 through 15 to n models feat ure a remov able upper f an m o dule that can be rot ated 180 ∞ for t op rea r dis - charge applicat i o ns. In addition, the blower outlet ...

  • York CH060 - page 22

    036-2 1217-001-B-1 203 22 Uni ta ry Prod ucts G roup FIGURE 9 - HOT W A T ER & S T EAM HEA TING COILS DIMENSIONAL DA T A Hot W ater and Steam Heating C oi l D im ensions (Inche s) Uni t Mode l A B C Inl et (MPT Ou tlet (MPT ) CU060 37.50 5.5 0 23 1 1/2 1 1/2 CU096 59.50 5.5 0 28 1 1/2 1 1/2 CU120 59.50 5.5 0 28 1 1/2 1 1/2 CU180 71.50 5.5 0 33 ...

  • York CH060 - page 23

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 23 FIGURE 10 - HOT WA TER & STEAM HEA TING CO I LS PERFORMANCE DA T A CU240 - 300 CU060 - 180 Steam Co i l Pe rformance @ 2 PSI G ï S team Heating Coils are tube-in-tu be ë steam distri butingí type to elimi nate risk of con - densate freezi ng. ï Coils are c onstructed of 5/8 inch diameter ...

  • York CH060 - page 24

    036-2 1217-001-B-1 203 24 Uni ta ry Prod ucts G roup FIGURE 1 1 - T YP I CAL W A TER-SIDE ECO NOMIZER PHYSICAL CO NFIGURA TION ...

  • York CH060 - page 25

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 25 FIGURE 12 - W A TER-SIDE ECONOMIZER PIPING SCHEMA TIC ...

  • York CH060 - page 26

    036-2 1217-001-B-1 203 26 Uni ta ry Prod ucts G roup FIGURE 13 - W A TER-SIDE ECONO MIZER CONTROL - 15-20 T O N V ERT I CAL (208-230 V/3PH/ 60HZ) ...

  • York CH060 - page 27

    036-21 217-001-B-1 203 Uni ta ry Prod ucts G roup 27 ...

  • York CH060 - page 28

    Subjec t t o c hange without notice. Printed in U.S.A. 036-2 1217-001-B-1 203 Cop yright © by Uni t ar y Products Group 200 4. All ri gh t s reser ved. Super sedes: 036-21217- 001-A-0503 Un itar y 500 5 No r man Product s Y ork OK Group Drive 73 069 ...

メーカー York カテゴリー Air Conditioner

York CH060のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CH060の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork CH060の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York CH060の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York CH060の取り付け説明書、サービスマニュアル、簡易説明書、またはYork CH060のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York CH060の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York CH060デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork CH060を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork CH060ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York CH060の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork CH060の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York CH060に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York CH060デバイスの基本機能を使うにあたってのヒント。 York CH060のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York CH060に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork CH060のメーカー/サービスへの連絡先に関する情報。

York CH060についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork CH060の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork CH060で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)