    Micro Motion ® F-Series Sensor Inst allation Manual Inst allation Manual P/N 20002298, Rev . C September 20 07 ...

  • Emerson F-SERIES SENSOR - page 2

    ...

  • Emerson F-SERIES SENSOR - page 3

    Sensor In stallation: F-Series 1 Before Y ou Begin Before Y ou Begin This manual describes ho w to install a Micro Motion ® F-Series sensor . The follo wi ng information is provided in this manual: Customer service For technical assistance, phone the Micr o Motion Customer Service depa rtment: • In the U.S.A., phone 800-522-MASS (800-522-6277) ( ...

  • Emerson F-SERIES SENSOR - page 4

    2 Sensor In stallation : F-Series Before Y ou Begin Specifications Full product specif ications can b e found in the F-Seri es Product Data Sheet, which is a v ailable from the Micro Motion web site at www .micromotion.com . Definitions The term MVD ™ transmitt er refers to the follo wing transmitter models: • Models 1500, 170 0, 2500, and 2700 ...

  • Emerson F-SERIES SENSOR - page 5

    Sensor In stallation: F-Series 3 Before Y ou Begin Figure 1 F-Series sensor with core p rocessor Approv al tag Flow direction arrow Core processor housing Calibration tag Process connection Approv al tag Calibration tag Core processor housing Purge fitting Purge fitting Sensor with purge fitt ings ...

  • Emerson F-SERIES SENSOR - page 6

    4 Sensor In stallation : F-Series Before Y ou Begin Figure 2 F-Series sensor with integrally mounted Model 1700/2700 transmitter Model 1700/2700 transmitter Approv al tag Flow direction arrow Core processor housing Calibration tag Process connection Calibration tag Approv al tag Purge fitting Purge fitting Model 1700 or 2700 transmitter Sensor wi t ...

  • Emerson F-SERIES SENSOR - page 7

    Sensor In stallation: F-Series 5 Before Y ou Begin Figure 3 F-Series sensor with junction box Junction bo x Approv al tag Flow direction arro w Approv al tag Process connection Calibration tag Purge fitting Purge fitting Junction bo x Sensor with purge fitt ings Calibration tag ...

  • Emerson F-SERIES SENSOR - page 8

    6 Sensor In stallation : F-Series Before Y ou Begin Figure 4 F-Series sensor with integra lly mounted IF T 9701 transmitter Calibration tag Flow direction arrow Model IFT9701 transmitter Approv al tag Process connection Model IFT9701 transmitter Approv al tag Calibration tag Purge fitting Purge fitting Sensor with purge fitt ings ...

  • Emerson F-SERIES SENSOR - page 9

    Sensor In stallation: F-Series 7 Before Y ou Begin Figure 5 High-temperature or extreme high-te mperature F-Series sensor with flexible conduit Flow direction arrow T ransmitter , core processo r , or junction box (core processor shown) Calibration tag Process connection Flex ible conduit Approv al tag ...

  • Emerson F-SERIES SENSOR - page 10

    8 Sensor In stallation : F-Series Determining a Location Step 1 Determining a Location Choose a location for the sensor based on the requirements descri bed in th is section. The foll o wing general guidelines can help you select an appropriate location fo r the sensor . Full flow tubes For op timal performance, the sensor tube s should remain full ...

  • Emerson F-SERIES SENSOR - page 11

    Sensor In stallation: F-Series 9 Determining a Locati on Figure 6 F-Series sensor ambie nt and process temperature limits (all models except high-temperature and extreme hig h-temperature models) Maximum process temperature in °F (°C) Mount electronics remote ly; use junction box –148 (–100) –112 (–80) –76 (–60) –40 (–40) –4 (? ...

  • Emerson F-SERIES SENSOR - page 12

    10 Sensor In stallation : F-Series Determining a Location Figure 7 F-Series sensor ambient an d process temperature limits (high-tempera ture and extreme high-temperature mo dels) Hazardous area approv als may impose additional limits on ambient and process temperature. For the A TEX “T” rating, refer to the A TEX documentation shipped w ith th ...

  • Emerson F-SERIES SENSOR - page 13

    Sensor In stallation: F-Series 11 Determining a Locati on Maximum wiring distances If the transmitter is mounted remote ly from the sensor , the maximum di stance between the sensor and transmitter depends on cable type. See T able 2. For high-temperat ure and extreme high-tempera ture F-Series sensors, note the follo wing: • For sensors with a M ...

  • Emerson F-SERIES SENSOR - page 14

    12 Sensor In stallation : F-Series Orientin g the Se nsor Step 2 Orienting the Sensor The sensor will function prop erly in an y orientation if the sensor tubes remain f illed with process fluid. Micro Motion reco mmends or ienting F-Series sensors as sho wn in Figure 8. Figure 8 Recommended se nsor orientations Self-draining applicati ons The F-Se ...

  • Emerson F-SERIES SENSOR - page 15

    Sensor In stallation: F-Series 13 Mounting the Se nsor Step 3 Mounting the Sensor Use your common practices to minimize torque and bendi ng load on process conn ections. Figure 9 illustrates ho w to mount the sensor . T o reduce the risk of co ndensation or excessi ve mois ture, the conduit opening should not point upward (if possib le). The condui ...

  • Emerson F-SERIES SENSOR - page 16

    14 Sensor In stallation : F-Series Mounting the Sensor Mounting the electronics of high-temperature and e xtreme high-temperature se nsors High-temperature and extreme high-tempera ture F-Series sensors come with a 32 ″ (812 mm) pre-installed flexible conduit. This conduit is required for agency appro v al. A factory- supplied Model 1700/2700 tra ...

  • Emerson F-SERIES SENSOR - page 17

    Sensor In stallation: F-Series 15 Wiring Step 4 Wiring Improperly sealed housings can expose electron ics to moisture, which can cause measurement err or or flowmeter failure. Inspect and grease all ga skets and O-rings. Fully close and tighten all housing cover s and conduit openings. Installation options The sensor has one o f the follo wi ng ele ...

  • Emerson F-SERIES SENSOR - page 18

    16 Sensor In stallation : F-Series Wiring Figure 11 Micro Motion cable gland an d heat shrink 4. For conn ection at the core processor housing, pr epare shielded cable as follo ws (for armored cable, omit steps d, e, f, and g): a. Strip 4 1/2 inches ( 114 mm) of cab le jack et. b . Remo v e the clear wrap that is inside the cable jack et, and remov ...

  • Emerson F-SERIES SENSOR - page 19

    Sensor In stallation: F-Series 17 Wiring Figure 13 Applying the heat shrink g. Position gland clamping inse rt so the interior end is flush with the heat shrink. h. Fold the cl oth shield or braid and drain wires o ver the clampin g insert and approximately 1/8 inch (3 mm) past the O-ring. Figure 14 Folding the cloth shield i. Install the gland bod ...

  • Emerson F-SERIES SENSOR - page 20

    18 Sensor In stallation : F-Series Wiring Figure 16 Connecting the wires at the core processor 7. Reinstall and tighten the co re processor housing co ver . 8. Additional wiring instructions for the tran smitter can be found in the transmitter manual. Note: Never gr ound the 4-wir e cable shield an d shield drain wir e(s) at the transmitter . Junct ...

  • Emerson F-SERIES SENSOR - page 21

    Sensor In stallation: F-Series 19 Grounding Step 5 Grounding The sensor can be groun ded via the piping if the joints in the pipeline are ground- bonded. If the sen sor is not grounded via the piping, con nect a ground wire to the in ternal or exter nal grounding scre w , which is located on the core processo r housing or junction box. Improper gr ...

  • Emerson F-SERIES SENSOR - page 22

    20 Sensor In stallation : F-Series Purge Fitt ings Purge Fittings If the sensor has pur ge fittings, the y should remain seal ed at all times. After a purge plug has been remo v ed, the sensor case should b e purged w ith ar gon or nitrogen and resealed. Purging the case protects internal components. The sensor is purged of all oxygen and sealed at ...

  • Emerson F-SERIES SENSOR - page 23

    Sensor In stallation: F-Series 21 Purge Fittings 8. Make sure the pur ge f itting seals are tight so air cannot be dra wn b y suction into the sensor case. Ta b l e 4 Time re quired to purge F-Se ries sensor cases Sensor model Purge rate ft 3 /hr (l/hr) Time (1) minutes (1) If pur ge lines ar e being used, incr ease pur ge time to f ill the additio ...

  • Emerson F-SERIES SENSOR - page 24

    22 Sensor In stallation : F-Series Return Policy Return Policy Micro Motion procedu res must be followed when retu rning equipment. These procedures ensure le gal compliance with go vernment transpor tation agencies and help pro vide a safe working en vironment for Micro Motion employees. F ailure to follo w Micro Motion proced ures will result in ...

  • Emerson F-SERIES SENSOR - page 25

    ...

  • Emerson F-SERIES SENSOR - page 26

    Micro Motion Inc. USA Worldwide Headqu arters 7070 Winchester Circle Boulder , Colorado 80301 T +1 303-527-5200 +1 800-522-6277 F +1 303-530-8459 Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 Micro Motion Japan Emerson Process Management 1-2-5, Higashi Shinagawa S ...

メーカー Emerson カテゴリー Home Security System

Emerson F-SERIES SENSORのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- F-SERIES SENSORの取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson F-SERIES SENSORの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson F-SERIES SENSORの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson F-SERIES SENSORの取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson F-SERIES SENSORのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson F-SERIES SENSORの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson F-SERIES SENSORデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson F-SERIES SENSORを使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson F-SERIES SENSORユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson F-SERIES SENSORの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson F-SERIES SENSORの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson F-SERIES SENSORに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson F-SERIES SENSORデバイスの基本機能を使うにあたってのヒント。 Emerson F-SERIES SENSORのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson F-SERIES SENSORに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson F-SERIES SENSORのメーカー/サービスへの連絡先に関する情報。

Emerson F-SERIES SENSORについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson F-SERIES SENSORの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson F-SERIES SENSORで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)