Johnson Controls 13 SEER - GCGDの取扱説明書

16ページ 0.45 mb
ダウンロード

ページに移動 of 16

Summary
  • Johnson Controls 13 SEER - GCGD - page 1

    Johnson Controls Unitary Produ cts 1031452-UIM-B-0513 R-22 OUTDOOR SPLIT -SYSTEM AIR CONDITIONING SHIPPED WITH NITROGEN CHARGE ONL Y MODELS: 13 SEER - GC GD 1.5 TO 5 T ONS INSTALLATION MANUAL ® LIST OF SECTIONS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY . . . . . . . . . . . . . . . ...

  • Johnson Controls 13 SEER - GCGD - page 2

    1031452-UIM-B-0513 2 Johnson Controls Unitary Products LIMIT A TIONS The unit should be installed in accordance with all National, S tate and Local Safety Codes and the limitations listed below: 1. Limitations for the indoor unit, coil, and appropriate accessories must also be observed. 2. The outdoor unit must not be installed with any duct work i ...

  • Johnson Controls 13 SEER - GCGD - page 3

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 3 LIQUID LINE FIL TER-DRIER The air conditioning unit’s copper spun filter/dryer is located on the liq - uid line. PIPING CONNECTIONS The outdoor condensing unit must be connected to the indoor evapora - tor coil using field supplied r efrigerant grade (ACR) co pper tubing that is internally c ...

  • Johnson Controls 13 SEER - GCGD - page 4

    1031452-UIM-B-0513 4 Johnson Controls Unitary Products Connect the refrigerant lines u sing the following proced ure: 1. Remove the cap and Schrader core from both the liquid and vapor service valve service ports at the outdoor unit. Connect low pres- sure nitrogen to the liquid line service port. 2. Braze the liquid line to the liqui d valve at th ...

  • Johnson Controls 13 SEER - GCGD - page 5

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 5 SECTION V : TXV INST ALLA TIONS The following are the basic steps fo r inst allation. For detailed instruc- tions, refer to the Installation Instructions accompanying the TXV kit. Install TXV kit as follows: 1. Relieve the holding charge by pulling off the rubber cap plug on the suction manifo ...

  • Johnson Controls 13 SEER - GCGD - page 6

    1031452-UIM-B-0513 6 Johnson Controls Unitary Products SUPERHEA T CHARGING METHOD - PIST ON INDOOR 1. Operate system until temperatures and pressures stabilize (mini- mum of 10 minutes). 2. Measure and record indoor wet bulb (WB) temperature using a sling psychrometer and the outdoor dry bulb (DB) temperature using a thermometer . 3. Measure and re ...

  • Johnson Controls 13 SEER - GCGD - page 7

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 7 FIELD CONNECTIONS CONTR OL WIRING 1. Route low voltage wiring into bottom of control box as shown in Figure 6. Make low voltage wiring conne ctions inside the low volt- age box per Figures 7 - 1 1. 2. The complete connection diagram and schematic wiring label is located on the inside surface o ...

  • Johnson Controls 13 SEER - GCGD - page 8

    1031452-UIM-B-0513 8 Johnson Controls Unitary Products For additional connection diagrams for a ll UPG equipment refer to “Low V oltage System Wiring” document available online at www . upgnet.com in the Product Catalog Section. FIGURE 8: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1A Single Stage Air Conditioner – PSC Air Han ...

  • Johnson Controls 13 SEER - GCGD - page 9

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 9 FIGURE 9: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1B Single Stage Air Conditioner – PSC Air Handler C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER MA SHP AHP ID MODELS SINGLE STAGE AIR CONDIT I O N ER Other Part Nu mbers: SAP = Legacy 265902 = ...

  • Johnson Controls 13 SEER - GCGD - page 10

    1031452-UIM-B-0513 10 Johnson Controls Unitary Products FIGURE 10: Thermostat Chart - Single S tage AC with PSC Furnace AC 5A Single Stage Air Conditioner – Single Stage PSC Furnace G*9F G*(8/9)S F*(8/9) S PS(8/9) GF(8/9) G8C L*8S C 24 – Volt Comm on R 24 – Volt Hot W Full Stage Heat Y / Y2 Second or Full Stage Compressor SINGLE STAGE PSC FUR ...

  • Johnson Controls 13 SEER - GCGD - page 11

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 11 FIGURE 1 1: Thermostat Chart - Single S tage AC with PSC Furnace AC 5B Single Stage Air Conditioner – Single Stage PSC Furnace C 24 – Volt Comm on Y Compressor Contactor SINGLE STAGE AIR CONDIT IONER SINGLE STAGE AIR CONDIT I O N ER Y Full Stage Compressor G Fan *BP11C50124 *BN11C01124 *D ...

  • Johnson Controls 13 SEER - GCGD - page 12

    1031452-UIM-B-0513 12 Johnson Controls Unitary Products SECTION IX: INSTRUCTING THE O WNER Assist owner with processing warr anty cards and/or online registration. Review Owners Guide and provide a copy to the owner and guidance on proper operation and maintenance. I nstruct the owner or the opera- tor how to start, stop and adjust temperature sett ...

  • Johnson Controls 13 SEER - GCGD - page 13

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 13 SECTION X: WIRING DIAGRAM FIGURE 12: Wiring Diagram ...

  • Johnson Controls 13 SEER - GCGD - page 14

    1031452-UIM-B-0513 14 Johnson Controls Unitary Products NOTES ...

  • Johnson Controls 13 SEER - GCGD - page 15

    1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 15 SECTION XI: ST ART UP SHEET Air Conditioning and Heating Start-Up Sheet Proper start-up is critical to customer comfort and equipment longevity Name Address City State or Province Zip or Postal Code Indoor Unit Model # Indoor Unit Serial # Indoor Coil Model # Indoor Coil Serial # Upflow Downf ...

  • Johnson Controls 13 SEER - GCGD - page 16

    Subject to change without not ice. Published in U.S.A. 1031452-UIM-B-0513 Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 1031452-UIM-A-0413 Y ork Internat ional Corp. 5005 Y ork Driv e Norman, OK 73069 Supply static after indoor coil (in w.c.") Return Static (in w.c.") before filter Total External Static Pres ...

メーカー Johnson Controls カテゴリー Air Conditioner

Johnson Controls 13 SEER - GCGDのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 13 SEER - GCGDの取扱説明書
- Johnson Controlsの製品カード
- パンフレット
- またはJohnson Controls 13 SEER - GCGDの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Johnson Controls 13 SEER - GCGDの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Johnson Controls 13 SEER - GCGDの取り付け説明書、サービスマニュアル、簡易説明書、またはJohnson Controls 13 SEER - GCGDのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Johnson Controls 13 SEER - GCGDの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Johnson Controls 13 SEER - GCGDデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがJohnson Controls 13 SEER - GCGDを使用するのを助ける技術的文書のことです。説明書は通常、全てのJohnson Controls 13 SEER - GCGDユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Johnson Controlsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Johnson Controls 13 SEER - GCGDの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははJohnson Controls 13 SEER - GCGDの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Johnson Controls 13 SEER - GCGDに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Johnson Controls 13 SEER - GCGDデバイスの基本機能を使うにあたってのヒント。 Johnson Controls 13 SEER - GCGDのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Johnson Controls 13 SEER - GCGDに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるJohnson Controls 13 SEER - GCGDのメーカー/サービスへの連絡先に関する情報。

Johnson Controls 13 SEER - GCGDについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもJohnson Controls 13 SEER - GCGDの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがJohnson Controls 13 SEER - GCGDで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)