Cabletron Systems 9F310-02の取扱説明書

30ページ 0.4 mb
ダウンロード

ページに移動 of 30

Summary
  • Cabletron Systems 9F310-02 - page 1

    MMAC-Plus ™ 9F310-02 & 9F315-02 FDDI Switch Module User’s Guide ...

  • Cabletron Systems 9F310-02 - page 2

    ...

  • Cabletron Systems 9F310-02 - page 3

    i Notice Notice Cabletron Systems r eserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletr on Systems to determine whether any such changes have been made. The hardwar e, firmware, or softwar e described in this manual is subject to ...

  • Cabletron Systems 9F310-02 - page 4

    ii Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesir ed operation. NOTE: This equipment has been tested and found to c ...

  • Cabletron Systems 9F310-02 - page 5

    v Notice Safety Inf ormation CLASS 1 LASER TRANSCEIVERS The 9F315-02 is a Class 1 Laser Pr oduct The 9F315-02 uses Class 1 Laser transceivers. Read the following saf ety inf ormation before installing or operating these adapter s. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eli ...

  • Cabletron Systems 9F310-02 - page 6

    Notice vi Safety Inf ormation CLASS 1 LASER TRANSCEIVERS Laser Radiation and Connectors When the connector is in place, all laser radiation remains within the fiber . The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10 -6 watts. Removing the optical connector from the transceiver allows laser ra ...

  • Cabletron Systems 9F310-02 - page 7

    vii Contents Chapter 1 Intr oduction Features........................................................................................................................... 1-1 Related Manuals ............................................................................................................ 1-4 Getting Help ................................... ...

  • Cabletron Systems 9F310-02 - page 8

    Contents viii ...

  • Cabletron Systems 9F310-02 - page 9

    1-1 Chapter 1 Intr oduction The 9F310-02 and 9F315-02 are thr ee port switch modules with two front panel FDDI interfaces and one INB-1 backplane interface. The external FDDI networks are connected to the modules using standar d FDDI A/B ports on the front panel. The 9F310-02 uses multi mode fiber , and the 9F315-02 uses single mode fiber optic c ...

  • Cabletron Systems 9F310-02 - page 10

    Introduction 1-2 interfaces provide frames filter ed, frames forwarded, and all Spanning T ree Protocol parameters. The 9F310-02 and 9F315-02 modules support the IETF FDDI MIB (RFC-1512), IETF MIB ll (RFC-1213), IETF BRIDGE MIB (RFC-1493), and a host of Cabletron enterprise MIBs. In addition, the fr ont panel provides LEDs for FDDI link status per ...

  • Cabletron Systems 9F310-02 - page 11

    1-3 F eatures Figure 1-1. The 9F310-02 and 9F315-02 Modules MMAC PLUS MMAC PLUS MMAC PLUS MMAC PLUS ...

  • Cabletron Systems 9F310-02 - page 12

    Introduction 1-4 Related Manuals The manuals listed below should be used to supplement the procedur es and technical data contained in this manual. MMAC-Plus Installation Guide MMAC-Plus Operations Guide MMAC-Plus 9C300-1 Environmental Module User ’ s Guide MMAC-Plus 9C214-1 AC Power Supply User ’ s Guide INB T erminator Modules Installation Gu ...

  • Cabletron Systems 9F310-02 - page 13

    2-1 Chapter 2 Installing the MMA C-Plus modules The 9F310-02 and 9F315-02 modules occupy two slots in the MMAC-Plus chassis. The modules must be installed with the left side (as viewed from the fr ont) in an odd numbered slot, and the right side in an even number ed slot. T o install the 9F310-02 and 9F315-02, follow the steps below: 1. Switch off ...

  • Cabletron Systems 9F310-02 - page 14

    Installing the MMA C-Plus modules 2-2 Figure 2-1. Installing the 9F310-02 and 9F315-02 Modules 7 F LN K 8 F LN K F LN K 10 F LN K I NS 11 F LN K I NS 12 RX TX RX TX RX Circuit Card Card Guides Metal Back-Panel Jack for ESD wrist strap W arning: Ensure that the circuit card is between the card guides . Lock do wn the top and bottom plastic tabs at t ...

  • Cabletron Systems 9F310-02 - page 15

    2-3 The Reset Switch The Reset Switch The Reset switch is located on the rightmost front panel, under the top plastic tab as shown in Figure 2-2. It serves two functions: • Pressing the r eset switch twice within three seconds causes the pr ocessor (i960) to reset. • Pressing and holding the switch on for thr ee or more seconds causes the modul ...

  • Cabletron Systems 9F310-02 - page 16

    Installing the MMA C-Plus modules 2-4 User Accessible Components Figure 2-3 shows the various components that ar e accessible to the user . These consist of an eight position dip switch (explained below), replaceable PROMs and sockets for RAM. These will be used for future upgrades. Instr uctions for installing the components will be supplied with ...

  • Cabletron Systems 9F310-02 - page 17

    2-5 User Accessible Components See the Cautions at the end of this table. T able 2-1. Function of DIP Switch Switch Function Description 8 Clear Password 1 When toggled, this switch clears user-enter ed passwords stor ed in NVRAM, and restor es the default passwords. Once r eset you can use the defaults or enter new passwords. 7 Clear NVRAM 2 The m ...

  • Cabletron Systems 9F310-02 - page 18

    Installing the MMA C-Plus modules 2-6 ...

  • Cabletron Systems 9F310-02 - page 19

    3-1 Chapter 3 Operation The 9F310-02 and 9F315-02 modules are capable of bridging/switching any thr ee, of five possible interfaces, depending on how it is configured. The INB-1 connection is always fixed. When configuring the module, the decision is made to connect both front panel ports, both FNB ports, or one fr ont panel and one FNB port to ...

  • Cabletron Systems 9F310-02 - page 20

    Operation 3-2 System Management Buses There ar e two management channels within the MMAC-Plus system: the SMB-1 and the SMB-10. These buses provide out-of-band management and inter -module management communication. SMB-1 Bus The SMB-1 is a 1Mbs management bus located within the MMAC-Plus. This bus is utilized by all diagnostic controllers in the sy ...

  • Cabletron Systems 9F310-02 - page 21

    3-3 DC/DC Conv er ter DC/DC Con verter The DC/DC converter converts the 48 VDC on the system power bus to the necessary operating voltages for its host network services module. The diagnostic controller monitors and contr ols the operation of the DC/DC converter . INB Interface Each module that attaches to the INB has an INB Network Interface Block ...

  • Cabletron Systems 9F310-02 - page 22

    Operation 3-4 The Host engine sends and receives packets via the CPU FPS Interface. This allows the bridge to perform spanning tree pr otocol and other bridging functions. The SMB Interfaces provide communication to the Host Engine for management functions and communication with other modules in the chassis. ...

  • Cabletron Systems 9F310-02 - page 23

    4-1 Chapter 4 LANVIEW LEDs The front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in trouble shooting. Shown in Figur e 4-1 is the LANVIEW LEDs of the 9F310-02 and 9F315-02 module. Figure 4-1. The LANVIEW LEDs INB T ransmit FDDI Status INB Receiv e FDDI Receiv e FDDI T ransmit System Status ...

  • Cabletron Systems 9F310-02 - page 24

    LANVIEW LEDs 4-2 The function of the two System Status LEDs, System Management Bus (SMB) and the CPU, are listed in T able 4-1. The function of the INB receive LEDs ar e listed in T able 4-2. The function of the INB transmit LEDs are listed in T able 4-2. T able 4-1. System Status (SMB and CPU) LEDs LED Color State Description Green Functional Full ...

  • Cabletron Systems 9F310-02 - page 25

    4-3 The function of the FDDI receive LEDs ar e listed in T able 4-4. The function of the FDDI transmit LEDs are listed in T able 4-2. The FDDI status LEDs display the status when bridging to the front panel port from either FNB ring. The “A” and “B” LEDs indicate the status of the A and B ports. The “P” and “S” LEDs indicate the sta ...

  • Cabletron Systems 9F310-02 - page 26

    LANVIEW LEDs 4-4 The functions of the FDDI Status LEDs are listed in T able 4-6. T able 4-6. FDDI Status LEDs A P S B ST A TE Green N/A N/A Gr een Ports Enabled & Active Green Gr een Off Green THRU A, MAC on Primary , Secondary Bypasses Board Green Gr een Y ellow Green THRU A, MAC on Primary , No MAC on Secondary Green Of f Green Gr een THRU B, ...

  • Cabletron Systems 9F310-02 - page 27

    5-1 Chapter 5 Specifications T echnical Specifications CPU: Intel i960 RISC based micropr ocessor Memory: 4 Meg. Local RAM (expandable to 12 Meg.) 2 Meg. Flash Memory (expandable to 16 Meg.) 2 Meg. Packet RAM Standards: ANSI FDDI X3T9.5 SMT MAC PHY MMF-PMD SMF-PMD Network Interfaces: A/B ports MMF Connectors ...

  • Cabletron Systems 9F310-02 - page 28

    Specifications 5-2 Safety This equipment meets the safety requir ements of: • UL 1950 • CSA C22.2 No. 950 • EN 60950 • IEC 950 • EMI Requirements of FCC Part 15 Class A • EN 55022 Class A • VCCI Class I • EMC requir ements of: EN 50082-1 IEC 801-2 ESD IEC 801-3 Radiated susceptibility IEC 801-4 EFT Service MTBF (MHBK-217E) >200, ...

  • Cabletron Systems 9F310-02 - page 29

    5-3 Link Distance 9F310-02 Up to 2 kilometers on multimode fiber-optic cable as specified by ANSI MMF-PMD. 9F315-02 40 kilometers (max), 25 kilometer (typical) on single-mode fiber-optic cable as specified by ANSI SMF-PMD. ...

  • Cabletron Systems 9F310-02 - page 30

    Specifications 5-4 ...

メーカー Cabletron Systems カテゴリー Switch

Cabletron Systems 9F310-02のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 9F310-02の取扱説明書
- Cabletron Systemsの製品カード
- パンフレット
- またはCabletron Systems 9F310-02の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cabletron Systems 9F310-02の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cabletron Systems 9F310-02の取り付け説明書、サービスマニュアル、簡易説明書、またはCabletron Systems 9F310-02のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cabletron Systems 9F310-02の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cabletron Systems 9F310-02デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCabletron Systems 9F310-02を使用するのを助ける技術的文書のことです。説明書は通常、全てのCabletron Systems 9F310-02ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Cabletron Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cabletron Systems 9F310-02の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCabletron Systems 9F310-02の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cabletron Systems 9F310-02に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cabletron Systems 9F310-02デバイスの基本機能を使うにあたってのヒント。 Cabletron Systems 9F310-02のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cabletron Systems 9F310-02に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCabletron Systems 9F310-02のメーカー/サービスへの連絡先に関する情報。

Cabletron Systems 9F310-02についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCabletron Systems 9F310-02の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCabletron Systems 9F310-02で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)