  • Emerson 16C26S-010 - page 1

    UST Universal Slim Twin Model Number 16C26S-010 OWNERS MANUAL • Installation • Operation • Basic UST Service Guide • T echnical Repair Guide • Repair Parts Part No. 37-6070A Replaces 846-2027 Rev B 0015 Electronic Air Cleaner Printed In U.S.A. UL Listed CSA Certified by White-Rodgers Please read and familiarize yourself with the contents ...

  • Emerson 16C26S-010 - page 2

    2 RULES FOR SAFE INST ALLA TION AND OPERA TION Please read instructions before installing and using the Electronic Air Cleaner. This will help you obtain the full benefit from the Electronic Air Cleaner you have selected. WARNING ! ELECTROCUTION HAZARD Shut off power at fuse panel before servicing. Failure to do so could result in serious personal ...

  • Emerson 16C26S-010 - page 3

    3 HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B). Here each tiny particle receives a positive electrical charge. These c ...

  • Emerson 16C26S-010 - page 4

    4 PREINST ALLA TION facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabi- net tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires). LOCATING THE AIR FILTER Your electroni ...

  • Emerson 16C26S-010 - page 5

    5 TYPICAL MOUNTING POSITIONS BASEMENT FURNACE (LOWBOY) (Figure 6) Cleaner is mounted hori- zontally in return plenum, just above furnace. COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted horizon- tally in return duct or plenum, just above furnace. HIGHBOY FURNACE (Figure 8) Side installation. Cleaner is mounted vertically, where return air enters ...

  • Emerson 16C26S-010 - page 6

    6 INST ALLA TION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation. INSTALLATION The following is a typical installation of the air cleaner on a “ ...

  • Emerson 16C26S-010 - page 7

    7 WIRING INSTRUCTIONS 7. With the cabinet installed, the air cleaner can now be wired to electrical input source. WARNING ! Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to in- stallation. Failure to do so could result in serious personal injury or death. 8. The ai ...

  • Emerson 16C26S-010 - page 8

    8 An alternate method for controlling the air cleaner operation is to install an F859-0381 Air Flow Switch/ Harness Kit (available separately) that switches power to the air cleaner when airflow is detected. NOTE: The air cleaner should not be operating un- less the furnace blower is on. 11. With the cabinet Installed, reinstall pre-filter(s) and c ...

  • Emerson 16C26S-010 - page 9

    9 3. Release the latch on top of power pack and pull the power pack straight away from cabinet at the top. Then lift pack out of ledge at bottom edge of cabinet. Set power pack aside. 4. Remove the cell(s) and pre-filter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) and pre-filter(s) for 20 to 30 minutes. N ...

  • Emerson 16C26S-010 - page 10

    10 SERVICE INDICA TION SER VICE CHECKS ON/OFF switch “ON” Unit functioning Normally Blower ON Operating Light ON ON/OFF switch “ON” 1. Power is not being supplied to air cleaner . Blower ON A. Check fuse or circuit breaker . Operating Light OFF B. Ensure power pack is properly installed and latched. 2. Collecting cell shorted - T urn power ...

  • Emerson 16C26S-010 - page 11

    11 TECHNICAL REP AIR GUIDE All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact. NOTE: When servicing the power pack components, all wiring must be routed to factory specific ...

  • Emerson 16C26S-010 - page 12

    12 POWER SUPPLY CHECKOUT PROCEDURE 1. Turn power switch to the “OFF” position and remove the power pack from cabinet. 2. Place power pack on a well insulated workbench. Connect meter negative (-) lead to the sheet metal chassis and the high voltage probe to high voltage contact on back cover of power pack. Connect AC power to power pack using a ...

  • Emerson 16C26S-010 - page 13

    13 NOTES ...

  • Emerson 16C26S-010 - page 14

    14 REP AIR P AR TS ...

  • Emerson 16C26S-010 - page 15

    15 ITEM NO. DESCRIPTION P ART NUMBER 16C28S-010 1 Cabinet N/A 2 Pre-Filter • F825-0337 3 Collecting Cell • F81 1-0321 4 Junction Box Cover F838-0072 5 * Screw #6 x 3/8 ------ 6 Connector , Female F818-0053 7 Power Pack Assembly F858-0921 8 Cell Handle F832-0039 9 Ionizing Wire F843-0500 10 Light F844-0131 1 1 Switch F876-0202 12 Power Pack, Cab ...

  • Emerson 16C26S-010 - page 16

    White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63 123-5398 314-577-1300 • FAX 314-577-1517 www.white-rodgers.com Controlling America’s Indoor Comfort NOTICE T O CONSUMERS White-Rodgers Electronic Air Cleaner Dear Consumer; White-Rodgers would like to thank you for purchasing a White-Rodgers Electronic Air Cleaner o ...

メーカー Emerson カテゴリー Air Cleaner

Emerson 16C26S-010のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 16C26S-010の取扱説明書
- Emersonの製品カード
- パンフレット
- またはEmerson 16C26S-010の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Emerson 16C26S-010の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Emerson 16C26S-010の取り付け説明書、サービスマニュアル、簡易説明書、またはEmerson 16C26S-010のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Emerson 16C26S-010の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Emerson 16C26S-010デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmerson 16C26S-010を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmerson 16C26S-010ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Emersonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Emerson 16C26S-010の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmerson 16C26S-010の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Emerson 16C26S-010に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Emerson 16C26S-010デバイスの基本機能を使うにあたってのヒント。 Emerson 16C26S-010のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Emerson 16C26S-010に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmerson 16C26S-010のメーカー/サービスへの連絡先に関する情報。

Emerson 16C26S-010についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmerson 16C26S-010の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmerson 16C26S-010で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)