  • Elinchrom BX100 - page 1

    English Multivoltage 90/260V elinca sa switzerland www .elinchr om.com Operating Manual Elinca S.A Style BX 01.09.2008 ENG (73286) Printed in S wi tzerland Style BX 100/400 ...

  • Elinchrom BX100 - page 2

    1 P .S: T echnical data subject to change. The listed values ar e guide values which may vary due to tolerances in components used. Introduction 2 Declaration of conformit y , disposal and recycling, CE marking 3 Safety notice and precaution 4 Operating instructions 5 Control P anel 6 Switch and Fuse 7 Modelling Light 8 Digital power display , Phot ...

  • Elinchrom BX100 - page 3

    2 The quality of light and ex ceptional performance is the result of long research, application of demanding principles, the long experience of ELINCHROM in lighting products for the studio and the utilization of the latest technology in this area. T otally integrated to the r ange of the ELINCHROM ashes, the Style 100BX - 400BX units maintain t ...

  • Elinchrom BX100 - page 4

    3 CE marking The shipped version of this device complies with the requirements of ECC dir ectives 89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage dir ective». Notational Conventions The meaning of the symbols and fonts used in this manual are as f ollows: Pa y particular attention to text marked with this symbol. F ailure ...

  • Elinchrom BX100 - page 5

    4 • T ransport the ash unit with care and only in its original packaging or another corresponding packaging t to protect it against knocks and jolts. • T ransport only in complete discharged conditions. W ait a minimum 30 minutes after removing from mains supply befor e packaging and transportation. • Never drop the ash unit (danger ...

  • Elinchrom BX100 - page 6

    5 3 1 6 11 12 The units Style BX (Multivoltage) are adapted f or operation on 90 - 260V/50 - 60Hz. Before connecting for the rst time, check to mak e sure that your Modelling lamp coincides with the voltage line. They must always be connected to an earthed ( gr ounded) mains supply . All Style BX units have a ba yonet mount and locking ring re? ...

  • Elinchrom BX100 - page 7

    6 Overview of controls 1. Mains inlet socket 2. Mains fuse (slow blow) 3. Mains light up on/off switch 4. Modelling fuse (f ast blow) 5. Open-ash 6. Synchro-sock ets + jack 3.5 mm 7 . Digital power display and char ge/discharge indicator 8. Acoustic recharging signal (Beep) 9. Slave cell switch on/off 10. Photocell receptor 11. Power adjustment ...

  • Elinchrom BX100 - page 8

    7 2 3 1 Mains fuse Modelling fuse Mains switch (Only tempered) Mains socket 4 Mains Supply With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug of the original ELINCHROM mains cord into the mains socket (1). Mains Switch The switch should light up when the compact is switched on ("I" position). (Switch ...

  • Elinchrom BX100 - page 9

    8 Modelling lamps and fuse for 90/140V Unit Modelling lamp Code Socket Fuse Code Style 100BX 150W Halostar 23019 E27 4AF 19035 Style 400BX 150W Halostar 23019 E27 4AF 19035 Option: 150W Halogen 23031 GX 6,35 4AF 19035 Option: 200W Halogen 23033 GX 6,35 4AF 19035 The touch pad (14) controls the modelling lamp on/off and the proportional light. Selec ...

  • Elinchrom BX100 - page 10

    9 10 Photocell receptor 5 T est and ready 9 Cell Modellling light controls Power displa y The actual ash power is displayed in a f -stop compatible format. The power range is 5 f -stops. The digital display , provides continuous power indication of the ash and modelling lamp. The controls cov er a continuous output range from full power 1/1 t ...

  • Elinchrom BX100 - page 11

    10 EL -Skyport triggers ashes without sync cords over a distance of approximately 100 m. Further detailed information please nd under : www .elinchrom.com / Products / RX Multi Remote Open ash "test" Having pressed the touch pad to release a ash, the green «READ Y» light will appear again once the unit is recharged. If the g ...

  • Elinchrom BX100 - page 12

    11 If the unit does not ash but the ON/OFF switch indicates that there is power , it could be that the ash tube needs replacing. Note:Flash tubes (Swiss quality) have a long life with average use, but multiashing in long sequences can cause overheating of the electrodes leading to pr ematur e ageing, or perhaps the astube is br oken or ...

  • Elinchrom BX100 - page 13

    12 Flash power J(Ws) 100 400 Power supply V 90/260 90/260 F-stop, 1m, 100 ISO , with reector 48° 32,5 64,5 Control range J(Ws) 5-100 25-400 Recycling time (230 V) s 0,2-0,5 0,3-1,1 Flash duration (t 0,5) 1/1 s 1/1700 1/850 (t 0,5) 1/16 s 1/1150 1/450 Modelling output W 150 150 V oltage across sync cable V 5 5 Connected load A/V A (W) 8/2080 8/2 ...

  • Elinchrom BX100 - page 14

    13 Single units do not include Reflectors - Product range and specifications subject to change. No guarantee for misprints. EL-Skyport RX Trigger Set 19362 Digital RX 2400 230V: 10258 110V: 10257 Digital RX 1200 230 V: 10256 110 V: 10255 EL-Skyport RX Trigger Set 19362 Digital 1500 AS 230 V 10248 110 V 10247 Digital 3000 AS 230 V 10254 110 V 10253 ...

  • Elinchrom BX100 - page 15

    14 This ELINCHROM product will be repaired free of char ge by the vending agent if during a period of 24 months from date of purchase its working order is impaired thr ough a manufacturing or material defect. The fault y product should be immediately sent to the authorized dealer or ELINCA agent. This guarantee is not v alid for equipment which has ...

  • Elinchrom BX100 - page 16

    www.elinchrom.com ...

メーカー Elinchrom カテゴリー Camera Accessories

Elinchrom BX100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BX100の取扱説明書
- Elinchromの製品カード
- パンフレット
- またはElinchrom BX100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Elinchrom BX100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Elinchrom BX100の取り付け説明書、サービスマニュアル、簡易説明書、またはElinchrom BX100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Elinchrom BX100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Elinchrom BX100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがElinchrom BX100を使用するのを助ける技術的文書のことです。説明書は通常、全てのElinchrom BX100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Elinchromの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Elinchrom BX100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははElinchrom BX100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Elinchrom BX100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Elinchrom BX100デバイスの基本機能を使うにあたってのヒント。 Elinchrom BX100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Elinchrom BX100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるElinchrom BX100のメーカー/サービスへの連絡先に関する情報。

Elinchrom BX100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもElinchrom BX100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがElinchrom BX100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)