    19563-1-0706 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL F AN TYPE DIRECT VENT W ALL FURNACE For Installation in Manufactur ed (Mobile Home), Modular or Residential Homes MODEL DV -55E-5 EFFECTIVE DA TE JUL Y 2006 W ARNING: If not installed, operated and ma int ai ne d in acc or da nce wit h the ma nu fa ctu r - er's instruction ...

  • Empire Comfort Systems DV-55E-5 - page 2

    Page 2 19563-1-0706 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ...................................................................................................... 4 Requirements for Massac ...

  • Empire Comfort Systems DV-55E-5 - page 3

    19563-1-0706 Page 3 • Due to high temperatur es the appliance should be located out of traffic and away from furnitur e and draperies. • Children and adults should be alerted to the hazards of high surface temperatur es and should stay away to avoid burns or clothing ignition. • Y oung children should be carefully supervised when they are in ...

  • Empire Comfort Systems DV-55E-5 - page 4

    Page 4 19563-1-0706 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...

  • Empire Comfort Systems DV-55E-5 - page 5

    19563-1-0706 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above ? ...

  • Empire Comfort Systems DV-55E-5 - page 6

    Page 6 19563-1-0706 Introduction Al w a y s co n s u l t yo u r l oc a l B u il d i n g De p a r t m e nt r e g a rd i n g regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to Installer 1. Installer must leave instruction manual wit h owner after installation. 2. Insta ller must have owne r ...

  • Empire Comfort Systems DV-55E-5 - page 7

    19563-1-0706 Page 7 Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7mm 3/8” 9.5mm 10-40 feet 4-12 meters 1 ...

  • Empire Comfort Systems DV-55E-5 - page 8

    Page 8 19563-1-0706 W arning: Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are pr ovided in conversion kit attached to manifold pipe. 1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit. 2. Open brass union located between the gas v ...

  • Empire Comfort Systems DV-55E-5 - page 9

    19563-1-0706 Page 9 1. Pick a location on a wall with a clear space of 36" (91.4cm) high by 43" (109cm) wide in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearance s for servicing and proper installation. Be sure to locate the unit close enough to a 1 15 V AC wall receptacle to p ...

  • Empire Comfort Systems DV-55E-5 - page 10

    Page 10 19563-1-0706 Figure 4 Installing W all Bracket (Figures 5 and 6) After finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed. The bracket should be mounted to the wall studs, if possible, or anchored solidly to the wall. Use the (2) 10 x 1 1/2" (38mm) hex-head screws or (2) plastic ...

  • Empire Comfort Systems DV-55E-5 - page 11

    19563-1-0706 Page 1 1 V enting (Figures 7 and 8) This unit is vented directly out the back using the concentric vent tube assembly provided. See Figure 2 for vent hole location. This hole location can be conveniently moved closer to unit exhaust outlet tube to avoid wall stud interference if necessary . The orange silicone exhaust elbow would need ...

  • Empire Comfort Systems DV-55E-5 - page 12

    Page 12 19563-1-0706 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do not try to light ...

  • Empire Comfort Systems DV-55E-5 - page 13

    19563-1-0706 Page 13 The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a thr ee-prong [gr ounding] plug fo ...

  • Empire Comfort Systems DV-55E-5 - page 14

    Page 14 19563-1-0706 Proper Main Burner Flame The proper main burner flame will be a blue primary (inner) flame with a larger , lighter blue secondary (outer) blue flame. Figure 10 Cleaning Main Burner(s) Remove main burner(s) and apply air pressure inside the throat and ports of the main burner(s). Removing Main Burner(s) 1. Remove front grill ...

  • Empire Comfort Systems DV-55E-5 - page 15

    19563-1-0706 Page 15 Y our new furnace should provide many years of trouble free performance, however, a yearly inspection of the burners , flue passageways and the outlet vent assembly should be done. Be sure all passageways are open and clear of any obstruction, or soot build up. Be sure to shut off all power to the unit while performing this in ...

  • Empire Comfort Systems DV-55E-5 - page 16

    Page 16 19563-1-0706 FURNACE CONTROL BOARD DIAGNOSTICS F AUL T SEQUENCE CODE — TROUBLE SHOOTING GUIDE # of Blinks Fault Condition Fault Correction Steady On Control OK 1 Flash T emperature limit switch is open -Check Circulating Air Blower Inlet or Grill Outlet for Blockage, Inducer Blower/Circulating Air Blower Run to Cool Heat Exchanger and Lim ...

  • Empire Comfort Systems DV-55E-5 - page 17

    19563-1-0706 Page 17 INDEX P AR T NO. NUMBER DESCRIPTION INDEX P AR T NO. NUMBER DESCRIPTION 1 D V - 1 3 7 8 S H R O U D T O P 2 D V - 1 3 7 6 S H R O U D S I D E R I G H T 3 R - 2 5 2 1 A I R F I L T E R 4 D V - 1 3 7 5 F I L T E R R E T AI N E R 5 D V - 1 3 7 9 W A L L MO U N T IN G B R A C K E T 6 D V - 1 0 4 8 W A L L BR A C K ET - 2 R E Q 7 R ...

  • Empire Comfort Systems DV-55E-5 - page 18

    Page 18 19563-1-0706 ...

  • Empire Comfort Systems DV-55E-5 - page 19

    19563-1-0706 Page 19 SER VICE NOTES ...

  • Empire Comfort Systems DV-55E-5 - page 20

    Page 20 19563-1-0706 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

メーカー Empire Comfort Systems カテゴリー Furnace

Empire Comfort Systems DV-55E-5のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DV-55E-5の取扱説明書
- Empire Comfort Systemsの製品カード
- パンフレット
- またはEmpire Comfort Systems DV-55E-5の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Empire Comfort Systems DV-55E-5の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Empire Comfort Systems DV-55E-5の取り付け説明書、サービスマニュアル、簡易説明書、またはEmpire Comfort Systems DV-55E-5のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Empire Comfort Systems DV-55E-5の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Empire Comfort Systems DV-55E-5デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmpire Comfort Systems DV-55E-5を使用するのを助ける技術的文書のことです。説明書は通常、全てのEmpire Comfort Systems DV-55E-5ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Empire Comfort Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Empire Comfort Systems DV-55E-5の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmpire Comfort Systems DV-55E-5の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Empire Comfort Systems DV-55E-5に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Empire Comfort Systems DV-55E-5デバイスの基本機能を使うにあたってのヒント。 Empire Comfort Systems DV-55E-5のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Empire Comfort Systems DV-55E-5に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmpire Comfort Systems DV-55E-5のメーカー/サービスへの連絡先に関する情報。

Empire Comfort Systems DV-55E-5についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmpire Comfort Systems DV-55E-5の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmpire Comfort Systems DV-55E-5で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)