    www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-UL TRACOMM422 Automatic Four Por t ISA RS-422/485 Inter face Board Shop online at ...

  • Omega Engineering RS-422/485 - page 2

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Engineering RS-422/485 - page 3

    Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED ................................................................................ 1 F ACTORY D EFAULT S ETTINGS ......... ...

  • Omega Engineering RS-422/485 - page 4

    A PPENDIX A - T ROUBLESHOOTING .........................................19 A PPENDIX B - H OW T O G ET A SSISTANCE E RROR ! B OOKMARK NOT DEFINED . A PPENDIX C - E LECTRICAL I NTERFACE ...................................22 RS - 422 ..................................................................................................... 22 RS - 485 .... ...

  • Omega Engineering RS-422/485 - page 5

    Introduction OMG - ULTRA - COMM422 Page 1 Introduction Overview The OMG - ULTRA - COMM422 provides the PC with four additional RS - 422/485 serial ports for terminals, modems, printers, etc. The unique feature of the OMG - ULTRA - COM M422 is the ability to be RS - 485 compatible without the need for special software or drivers. This ability is esp ...

  • Omega Engineering RS-422/485 - page 6

    Card Setup OMG - ULTRA - COMM422 Page 2 Card Setup The OMG - ULTRA - C OMM422 contains several jumper straps, which must be set for proper operation. Address Selection Each port on the OMG - ULTRA - COMM422 occupies eight consecutive I/O locations. A DIP - switch is used to set the base address for these locations. The OMG - ULTRA - C OMM422 has a ...

  • Omega Engineering RS-422/485 - page 7

    Card Setup OMG - ULTRA - COMM422 Page 3 The second mode of address selection provides the compatibility mode. In this mode the DIP - switch sets the base address and the adapter occupies 32 consecutive I/O locations. The following tabl e illustrates the location of each port and its relationship to the other ports. Note: For switches 1 - 5 to becom ...

  • Omega Engineering RS-422/485 - page 8

    Card Setup OMG - ULTRA - COMM422 Page 4 Jumper Selections For ease of configuration, the headers are grouped by port. Port one headers have a ‘J1’ prefix; Port two headers have the ‘J2’ prefix, etc. For example, the header that controls the Port one IRQ selection is J1B; the header that controls the Port 2 IRQ selection is J2B. The silk - s ...

  • Omega Engineering RS-422/485 - page 9

    Card Setup OMG - ULTRA - COMM422 Page 5 Interrupt Modes Headers J1A through J4A select the interrupt modes for each port. Each port must be set in the correct mode to insure proper operation. ‘ N ’ indicates the ( N )ormal, single interrupt per port mode. ‘ S ’ Indicates the ( S )hared interru pt mode, which allows more than one port to acc ...

  • Omega Engineering RS-422/485 - page 10

    Card Setup OMG - ULTRA - COMM422 Page 6 RS - 485 Enable Modes RS - 485 is ideal for multi - drop or network environments. RS - 485 requires a tri - state driver (not dual - state) that will allow the electrical presence of the driver to be removed from the line. The driver is in a t ri - state or high impedance condition when this occurs. Only one ...

  • Omega Engineering RS-422/485 - page 11

    Card Setup OMG - ULTRA - COMM422 Page 7 Interface Mode Examples J1D – J4D AT RT NE Figure 6 - Headers J1D - J4D , RS - 422 AT RT NE Figure 7 - Headers J1D - J4D, RS - 485 ‘Auto’ Enabled, with ‘No Echo’ AT RT NE Figure 8 - Headers J1D - J4D, RS - 485 ‘Auto’ Enabled, with ‘Echo’ ...

  • Omega Engineering RS-422/485 - page 12

    Card Setup OMG - ULTRA - COMM422 Page 8 Inter face Mode Examples J1D – J4D (continued) AT RT NE Figure 9 - Headers J1D - J4D, RS - 485 ‘RTS’ Enabled, with ‘No Echo’ AT RT NE Figure 10 - Headers J1D - J4D, RS - 485 ‘RTS ’ Enabled, with ‘Echo’ ...

  • Omega Engineering RS-422/485 - page 13

    Card Setup OMG - ULTRA - COMM422 Page 9 Line Termination Typically, each end of the RS - 485 bus must have line terminating resistors (RS - 422 terminates at the receive end only). A 120 - ohm resistor is across each RS - 530/422/485 input in addition to a 1K ohm pull - up/pull - do wn combination that bias the receiver inputs. Headers J1E through ...

  • Omega Engineering RS-422/485 - page 14

    Card Setup OMG - ULTRA - COMM422 Page 10 Clock Modes The OMG - ULTRA - COMM422 employs a unique clocking option that allows the end user to select from divide by 4, divide by 2 and divide by 1 clocking modes. These modes are selected at Headers J1C through J4C. To select the Baud rates commonly associated with COM: ports (i.e. 2400, 4800, 9600, 19. ...

  • Omega Engineering RS-422/485 - page 15

    Card Setup OMG - ULTRA - COMM422 Page 11 Baud Rates and Divisors for the ‘Div1’ mode The following table shows some common data rates and the rates you should choose to match them if using the adapter in the ‘Div1’ mode. For this Data Rate Choose this Data Rate 1200 bps 3 00 bps 2400 bps 600 bps 4800 bps 1200 bps 9600 bps 2400 bps 19.2K bps ...

  • Omega Engineering RS-422/485 - page 16

    Card Setup OMG - ULTRA - COMM422 Page 12 Baud Rates and Divisors for t he ‘Div2’ mode The following table shows some common data rates and the rates you should choose to match them if using the adapter in the ‘Div2’ mode. For this Data Rate Choose this Data Rate 1200 bps 600 bps 2400 bps 1200 bps 4800 bps 2400bps 9600 bp s 4800 bps 19.2K bp ...

  • Omega Engineering RS-422/485 - page 17

    Installation OMG - ULTRA - COMM422 Page 13 Installation The OMG - ULTRA - COMM422 can be installed in any of the PC expansion slots. The OMG - ULTRA - COMM422 contains several jumper straps for each port that must be set for proper operation. 1. Turn off PC power. Disconnect the power cord. 2. Remove the PC case cover. 3. Locate an available slot a ...

  • Omega Engineering RS-422/485 - page 18

    Technical Description OMG - ULTRA - COMM422 Page 14 Technical Description The OMG - ULTRA - COMM422 utilizes the 16550 UAR T. This chip features programmable baud rates, data format, interrupt control and a 16 - byte input and output FIFO. Also available as options are the Startech 16C650 and the Texas Instruments 16C750 UARTs, that provide deeper ...

  • Omega Engineering RS-422/485 - page 19

    Technical Description OMG - ULTRA - COMM422 Page 15 Interrupts A good description of an interrupt and it’s importance to the IBM PC can be found in the book ‘Peter Norton’s In side the PC, Premier Edition’: “ One of the key things that makes a computer different from any other kind of man - made machine is that computers have the capabili ...

  • Omega Engineering RS-422/485 - page 20

    Technical Description OMG - ULTRA - COMM422 Page 16 Why use an ISP? The answer to the polling inefficiency was the I nterrupt S tatus P ort (ISP). The ISP is a read only 8 - bit register that sets a corresponding bit when an interrupt is pending. Port 1 interrupt line corresponds with Bit D0 of the status port, Port 2 with D1 etc. The use of this p ...

  • Omega Engineering RS-422/485 - page 21

    Technical Description OMG - ULTRA - COMM422 Page 17 Connector Pin Assignments DB - 9 Pin Assignments Signal Name Pin # Mode GND Ground 5 TX + Transmit Data Positive 4 Output TX - Transmit Data Negative 3 Output RTS+ Request To Send Positive 6 Output RTS - Request To Send Negative 7 Output RX+ Receive Data Positive 1 Input RX - Receive Data Negative ...

  • Omega Engineering RS-422/485 - page 22

    Specifications OMG - ULTRA - COMM422 Page 18 Spec ifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.H. Non - Condensing Manufacturing • IPC 610 - A Class - III standards are adhered ...

  • Omega Engineering RS-422/485 - page 23

    Appendix A - Troubleshooting OMG - ULTRA - COMM422 Page 19 Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the adapter and will be used in the troubleshooting procedures. By using this diskette an d following these simple steps, most common problems can be eliminated without the need to call Technical Support. 1. Identify al ...

  • Omega Engineering RS-422/485 - page 24

    Appendix A - Troubleshooting OMG - ULTRA - COMM422 Page 20 8. The following are known I/O conflicts: • The 278 and 378 settings may conflict with your printer I/O adapter. • 3B0 cannot be u sed if a Monochrome adapter is installed. • 3F8 - 3FF is typically reserved for COM1: • 2F8 - 2FF is typically reserved for COM2: • 3E8 - 3EF is typic ...

  • Omega Engineering RS-422/485 - page 25

    OMG - ULTRA - COMM422 Page 21 Appendix B - How To Get Assistance Please refer to Troubleshooting Guide prior to calling Technical Support. 1. Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below. 2. When calling for technical assistance, please have your user manual and current adapter se ...

  • Omega Engineering RS-422/485 - page 26

    Appendix C - Electrical Interface OMG - ULTRA - COMM422 Page 22 Appendix C - Electrical Interface RS - 422 The RS - 422 specification defin es the electrical characteristics of balanced voltage digital interface circuits. RS - 422 is a differential interface that defines voltage levels and driver/receiver electrical specifications. On a differentia ...

  • Omega Engineering RS-422/485 - page 27

    Appendix D - Asynchronous Communications OMG - ULTRA - COMM422 Page 23 Appendix D - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data r ate, error checking, handshaking, and character framing (start/stop b ...

  • Omega Engineering RS-422/485 - page 28

    Appendix E - Silk - Screen OMG - ULTRA - COMM422 Page 24 Appendix E - Silk - Screen 4.2" 8.0" 3.9" ...

  • Omega Engineering RS-422/485 - page 29

    Appendix F - Compliance Notices OMG - ULTRA - COMM422 Page 25 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has b een tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmf ...

  • Omega Engineering RS-422/485 - page 30

    W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OME GA ? ...

  • Omega Engineering RS-422/485 - page 31

    M 3 184 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders ...

メーカー Omega Engineering カテゴリー Network Router

Omega Engineering RS-422/485のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RS-422/485の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering RS-422/485の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering RS-422/485の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering RS-422/485の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering RS-422/485のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering RS-422/485の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Omega Engineering RS-422/485デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering RS-422/485を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering RS-422/485ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering RS-422/485の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering RS-422/485の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering RS-422/485に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering RS-422/485デバイスの基本機能を使うにあたってのヒント。 Omega Engineering RS-422/485のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering RS-422/485に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering RS-422/485のメーカー/サービスへの連絡先に関する情報。

Omega Engineering RS-422/485についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering RS-422/485の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering RS-422/485で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)