    www .omega.com e-mail: info@omega.com U ser ’ s Guide OMG-UL TRACOMM422 Automatic Four Por t ISA RS-422/485 Inter face Board Shop online at ...

  • Omega Engineering RS-422/485 - page 2

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Engineering RS-422/485 - page 3

    Contents I NTRODUCTION ..........................................................................1 O VERVIEW ................................................................................................ 1 W HAT ’ S I NCLUDED ................................................................................ 1 F ACTORY D EFAULT S ETTINGS ......... ...

  • Omega Engineering RS-422/485 - page 4

    A PPENDIX A - T ROUBLESHOOTING .........................................19 A PPENDIX B - H OW T O G ET A SSISTANCE E RROR ! B OOKMARK NOT DEFINED . A PPENDIX C - E LECTRICAL I NTERFACE ...................................22 RS - 422 ..................................................................................................... 22 RS - 485 .... ...

  • Omega Engineering RS-422/485 - page 5

    Introduction OMG - ULTRA - COMM422 Page 1 Introduction Overview The OMG - ULTRA - COMM422 provides the PC with four additional RS - 422/485 serial ports for terminals, modems, printers, etc. The unique feature of the OMG - ULTRA - COM M422 is the ability to be RS - 485 compatible without the need for special software or drivers. This ability is esp ...

  • Omega Engineering RS-422/485 - page 6

    Card Setup OMG - ULTRA - COMM422 Page 2 Card Setup The OMG - ULTRA - C OMM422 contains several jumper straps, which must be set for proper operation. Address Selection Each port on the OMG - ULTRA - COMM422 occupies eight consecutive I/O locations. A DIP - switch is used to set the base address for these locations. The OMG - ULTRA - C OMM422 has a ...

  • Omega Engineering RS-422/485 - page 7

    Card Setup OMG - ULTRA - COMM422 Page 3 The second mode of address selection provides the compatibility mode. In this mode the DIP - switch sets the base address and the adapter occupies 32 consecutive I/O locations. The following tabl e illustrates the location of each port and its relationship to the other ports. Note: For switches 1 - 5 to becom ...

  • Omega Engineering RS-422/485 - page 8

    Card Setup OMG - ULTRA - COMM422 Page 4 Jumper Selections For ease of configuration, the headers are grouped by port. Port one headers have a ‘J1’ prefix; Port two headers have the ‘J2’ prefix, etc. For example, the header that controls the Port one IRQ selection is J1B; the header that controls the Port 2 IRQ selection is J2B. The silk - s ...

  • Omega Engineering RS-422/485 - page 9

    Card Setup OMG - ULTRA - COMM422 Page 5 Interrupt Modes Headers J1A through J4A select the interrupt modes for each port. Each port must be set in the correct mode to insure proper operation. ‘ N ’ indicates the ( N )ormal, single interrupt per port mode. ‘ S ’ Indicates the ( S )hared interru pt mode, which allows more than one port to acc ...

  • Omega Engineering RS-422/485 - page 10

    Card Setup OMG - ULTRA - COMM422 Page 6 RS - 485 Enable Modes RS - 485 is ideal for multi - drop or network environments. RS - 485 requires a tri - state driver (not dual - state) that will allow the electrical presence of the driver to be removed from the line. The driver is in a t ri - state or high impedance condition when this occurs. Only one ...

  • Omega Engineering RS-422/485 - page 11

    Card Setup OMG - ULTRA - COMM422 Page 7 Interface Mode Examples J1D – J4D AT RT NE Figure 6 - Headers J1D - J4D , RS - 422 AT RT NE Figure 7 - Headers J1D - J4D, RS - 485 ‘Auto’ Enabled, with ‘No Echo’ AT RT NE Figure 8 - Headers J1D - J4D, RS - 485 ‘Auto’ Enabled, with ‘Echo’ ...

  • Omega Engineering RS-422/485 - page 12

    Card Setup OMG - ULTRA - COMM422 Page 8 Inter face Mode Examples J1D – J4D (continued) AT RT NE Figure 9 - Headers J1D - J4D, RS - 485 ‘RTS’ Enabled, with ‘No Echo’ AT RT NE Figure 10 - Headers J1D - J4D, RS - 485 ‘RTS ’ Enabled, with ‘Echo’ ...

  • Omega Engineering RS-422/485 - page 13

    Card Setup OMG - ULTRA - COMM422 Page 9 Line Termination Typically, each end of the RS - 485 bus must have line terminating resistors (RS - 422 terminates at the receive end only). A 120 - ohm resistor is across each RS - 530/422/485 input in addition to a 1K ohm pull - up/pull - do wn combination that bias the receiver inputs. Headers J1E through ...

  • Omega Engineering RS-422/485 - page 14

    Card Setup OMG - ULTRA - COMM422 Page 10 Clock Modes The OMG - ULTRA - COMM422 employs a unique clocking option that allows the end user to select from divide by 4, divide by 2 and divide by 1 clocking modes. These modes are selected at Headers J1C through J4C. To select the Baud rates commonly associated with COM: ports (i.e. 2400, 4800, 9600, 19. ...

  • Omega Engineering RS-422/485 - page 15

    Card Setup OMG - ULTRA - COMM422 Page 11 Baud Rates and Divisors for the ‘Div1’ mode The following table shows some common data rates and the rates you should choose to match them if using the adapter in the ‘Div1’ mode. For this Data Rate Choose this Data Rate 1200 bps 3 00 bps 2400 bps 600 bps 4800 bps 1200 bps 9600 bps 2400 bps 19.2K bps ...

  • Omega Engineering RS-422/485 - page 16

    Card Setup OMG - ULTRA - COMM422 Page 12 Baud Rates and Divisors for t he ‘Div2’ mode The following table shows some common data rates and the rates you should choose to match them if using the adapter in the ‘Div2’ mode. For this Data Rate Choose this Data Rate 1200 bps 600 bps 2400 bps 1200 bps 4800 bps 2400bps 9600 bp s 4800 bps 19.2K bp ...

  • Omega Engineering RS-422/485 - page 17

    Installation OMG - ULTRA - COMM422 Page 13 Installation The OMG - ULTRA - COMM422 can be installed in any of the PC expansion slots. The OMG - ULTRA - COMM422 contains several jumper straps for each port that must be set for proper operation. 1. Turn off PC power. Disconnect the power cord. 2. Remove the PC case cover. 3. Locate an available slot a ...

  • Omega Engineering RS-422/485 - page 18

    Technical Description OMG - ULTRA - COMM422 Page 14 Technical Description The OMG - ULTRA - COMM422 utilizes the 16550 UAR T. This chip features programmable baud rates, data format, interrupt control and a 16 - byte input and output FIFO. Also available as options are the Startech 16C650 and the Texas Instruments 16C750 UARTs, that provide deeper ...

  • Omega Engineering RS-422/485 - page 19

    Technical Description OMG - ULTRA - COMM422 Page 15 Interrupts A good description of an interrupt and it’s importance to the IBM PC can be found in the book ‘Peter Norton’s In side the PC, Premier Edition’: “ One of the key things that makes a computer different from any other kind of man - made machine is that computers have the capabili ...

  • Omega Engineering RS-422/485 - page 20

    Technical Description OMG - ULTRA - COMM422 Page 16 Why use an ISP? The answer to the polling inefficiency was the I nterrupt S tatus P ort (ISP). The ISP is a read only 8 - bit register that sets a corresponding bit when an interrupt is pending. Port 1 interrupt line corresponds with Bit D0 of the status port, Port 2 with D1 etc. The use of this p ...

  • Omega Engineering RS-422/485 - page 21

    Technical Description OMG - ULTRA - COMM422 Page 17 Connector Pin Assignments DB - 9 Pin Assignments Signal Name Pin # Mode GND Ground 5 TX + Transmit Data Positive 4 Output TX - Transmit Data Negative 3 Output RTS+ Request To Send Positive 6 Output RTS - Request To Send Negative 7 Output RX+ Receive Data Positive 1 Input RX - Receive Data Negative ...

  • Omega Engineering RS-422/485 - page 22

    Specifications OMG - ULTRA - COMM422 Page 18 Spec ifications Environmental Specifications Specification Operating Storage Temperature Range 0º to 50º C (32º to 122º F) - 20º to 70º C (- 4º to 158º F) Humidity Range 10 to 90% R.H. Non - Condensing 10 to 90% R.H. Non - Condensing Manufacturing • IPC 610 - A Class - III standards are adhered ...

  • Omega Engineering RS-422/485 - page 23

    Appendix A - Troubleshooting OMG - ULTRA - COMM422 Page 19 Appendix A - Troubleshooting A Serial Utility Diskette is supplied with the adapter and will be used in the troubleshooting procedures. By using this diskette an d following these simple steps, most common problems can be eliminated without the need to call Technical Support. 1. Identify al ...

  • Omega Engineering RS-422/485 - page 24

    Appendix A - Troubleshooting OMG - ULTRA - COMM422 Page 20 8. The following are known I/O conflicts: • The 278 and 378 settings may conflict with your printer I/O adapter. • 3B0 cannot be u sed if a Monochrome adapter is installed. • 3F8 - 3FF is typically reserved for COM1: • 2F8 - 2FF is typically reserved for COM2: • 3E8 - 3EF is typic ...

  • Omega Engineering RS-422/485 - page 25

    OMG - ULTRA - COMM422 Page 21 Appendix B - How To Get Assistance Please refer to Troubleshooting Guide prior to calling Technical Support. 1. Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed please see below. 2. When calling for technical assistance, please have your user manual and current adapter se ...

  • Omega Engineering RS-422/485 - page 26

    Appendix C - Electrical Interface OMG - ULTRA - COMM422 Page 22 Appendix C - Electrical Interface RS - 422 The RS - 422 specification defin es the electrical characteristics of balanced voltage digital interface circuits. RS - 422 is a differential interface that defines voltage levels and driver/receiver electrical specifications. On a differentia ...

  • Omega Engineering RS-422/485 - page 27

    Appendix D - Asynchronous Communications OMG - ULTRA - COMM422 Page 23 Appendix D - Asynchronous Communications Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data r ate, error checking, handshaking, and character framing (start/stop b ...

  • Omega Engineering RS-422/485 - page 28

    Appendix E - Silk - Screen OMG - ULTRA - COMM422 Page 24 Appendix E - Silk - Screen 4.2" 8.0" 3.9" ...

  • Omega Engineering RS-422/485 - page 29

    Appendix F - Compliance Notices OMG - ULTRA - COMM422 Page 25 Appendix F - Compliance Notices Federal Communications Commission Statement FCC - This equipment has b een tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmf ...

  • Omega Engineering RS-422/485 - page 30

    W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E G A ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OME GA ? ...

  • Omega Engineering RS-422/485 - page 31

    M 3 184 /0303 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders ...

Производитель Omega Engineering Категория Network Router

Документы, которые мы получаем от производителя устройства Omega Engineering RS-422/485 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Omega Engineering
- инструкции обслуживания RS-422/485
- паспорта изделия Omega Engineering
- информационные брошюры
- энергетические этикетки Omega Engineering RS-422/485
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Omega Engineering RS-422/485.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Omega Engineering RS-422/485, инструкции обслуживания, короткие инструкции или инструкции пользователя Omega Engineering RS-422/485. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Omega Engineering RS-422/485.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Omega Engineering RS-422/485, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Omega Engineering RS-422/485 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Omega Engineering RS-422/485.

Полная инструкция обслуживания Omega Engineering, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Omega Engineering RS-422/485 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Omega Engineering RS-422/485, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Omega Engineering RS-422/485, которое найдем в данном документе
3. Советы по использованию основных функций устройства Omega Engineering RS-422/485 - которые должны облегчить нам первые шаги во время использования Omega Engineering RS-422/485
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Omega Engineering RS-422/485
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Omega Engineering RS-422/485 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Omega Engineering RS-422/485?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Omega Engineering RS-422/485, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Omega Engineering RS-422/485 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)