Zephyr AK7848ASXの取扱説明書

19ページ 0.61 mb
ダウンロード

ページに移動 of 19

Summary
  • Zephyr AK7848ASX - page 1

    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © Zephyr Corporation Cypress AK7836ASX AK7842ASX AK7848ASX READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA. ...

  • Zephyr AK7848ASX - page 2

    www .zephyronline.com ...

  • Zephyr AK7848ASX - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr AK7848ASX - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr AK7848ASX - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr AK7848ASX - page 6

    List of Materials 4 www .zephyronline.com MODELS: AK7836ASX, AK7842ASX, AK7848ASX P ARTS SUPPLIED 1 - Hood 3 - Baf fl e fi lters (4 for AK7848ASX) 2 - Halogen light bulbs (3 for AK7548ASX) ( pre-installed ) 1 - 10” round transition adapter ( for dual internal and external blowers ) 1 - External blower wiring ( for external and in-line blower ) ...

  • Zephyr AK7848ASX - page 7

    5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow ...

  • Zephyr AK7848ASX - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef fi ciency for single blower and 10” round duct for dual, in-line, and external blowers. Always use rigid type metal ducts only . Flexible ducts could restrict ...

  • Zephyr AK7848ASX - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...

  • Zephyr AK7848ASX - page 10

    8 www .zephyronline.com Installation – Speci fi cations 35 15/16 ” (36”) 41 15/16 ” (42”) 47 15/16 ” (48”) 12” *10 ” 27” 4” 18” 1 1/8 ” 8 9/16 ” 13 3/16 ” 2 5/16 ” 6 7/16 ” 2” 2 1/16 ” C L 5 9/16” ext blwr k/o elec k/o 2 11 / 1 6 ” top side front 4 5/16 ” *10” transition used with dual, external and in ...

  • Zephyr AK7848ASX - page 11

    9 ELECTRICAL W ARNING All Electrical work must by performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...

  • Zephyr AK7848ASX - page 12

    10 www .zephyronline.com C/L C/L A B 12 3/8 ” min 30” 4” wood board fig. 2 fig. 1 Installation – Mounting the Range Hood 1. Measure distance from range top to hood bottom ( 30” min ) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. ( 12 3/8” from line A ) ( This is the top of the board used to hang th ...

  • Zephyr AK7848ASX - page 13

    11 CBI-600B AND PBI-1 100A BLOWER INST ALLA TION 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower pictured is a PBI-1 100A) 2. Connect male end of blower wire to female plug in the hood. (plug is located inside the hood behind the control panel) 3. Single Blower – ...

  • Zephyr AK7848ASX - page 14

    12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter . 2. Install threaded end of external blower wiring through external blower wiring knock out located inside the hood. 3. Place cap over threaded end of ...

  • Zephyr AK7848ASX - page 15

    13 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Features & Controls – Rocker Switch Controls ...

  • Zephyr AK7848ASX - page 16

    14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser . After cleaning, you m ...

  • Zephyr AK7848ASX - page 17

    15 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. I ...

  • Zephyr AK7848ASX - page 18

    T roubleshooting 16 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power co ...

  • Zephyr AK7848ASX - page 19

    17 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210009 Optional Accessories Single Internal Blower CBI-600B Dual Internal Blower PBI-1 100A External Blower CBE-1000 In-Line Blower PBN-1000A Vinyl Cover (36”) AK0636AB Vinyl Cover (42”) AK0642AB Vinyl Cover (48”) AK0648AB 12” Duct ...

メーカー Zephyr カテゴリー Ventilation Hood

Zephyr AK7848ASXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AK7848ASXの取扱説明書
- Zephyrの製品カード
- パンフレット
- またはZephyr AK7848ASXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Zephyr AK7848ASXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Zephyr AK7848ASXの取り付け説明書、サービスマニュアル、簡易説明書、またはZephyr AK7848ASXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Zephyr AK7848ASXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Zephyr AK7848ASXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがZephyr AK7848ASXを使用するのを助ける技術的文書のことです。説明書は通常、全てのZephyr AK7848ASXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Zephyrの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Zephyr AK7848ASXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははZephyr AK7848ASXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Zephyr AK7848ASXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Zephyr AK7848ASXデバイスの基本機能を使うにあたってのヒント。 Zephyr AK7848ASXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Zephyr AK7848ASXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるZephyr AK7848ASXのメーカー/サービスへの連絡先に関する情報。

Zephyr AK7848ASXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもZephyr AK7848ASXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがZephyr AK7848ASXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)