    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © Zephyr Corporation Cypress AK7836ASX AK7842ASX AK7848ASX READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA. ...

  • Zephyr AK7848ASX - page 2

    www .zephyronline.com ...

  • Zephyr AK7848ASX - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr AK7848ASX - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr AK7848ASX - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr AK7848ASX - page 6

    List of Materials 4 www .zephyronline.com MODELS: AK7836ASX, AK7842ASX, AK7848ASX P ARTS SUPPLIED 1 - Hood 3 - Baf fl e fi lters (4 for AK7848ASX) 2 - Halogen light bulbs (3 for AK7548ASX) ( pre-installed ) 1 - 10” round transition adapter ( for dual internal and external blowers ) 1 - External blower wiring ( for external and in-line blower ) ...

  • Zephyr AK7848ASX - page 7

    5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow ...

  • Zephyr AK7848ASX - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef fi ciency for single blower and 10” round duct for dual, in-line, and external blowers. Always use rigid type metal ducts only . Flexible ducts could restrict ...

  • Zephyr AK7848ASX - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...

  • Zephyr AK7848ASX - page 10

    8 www .zephyronline.com Installation – Speci fi cations 35 15/16 ” (36”) 41 15/16 ” (42”) 47 15/16 ” (48”) 12” *10 ” 27” 4” 18” 1 1/8 ” 8 9/16 ” 13 3/16 ” 2 5/16 ” 6 7/16 ” 2” 2 1/16 ” C L 5 9/16” ext blwr k/o elec k/o 2 11 / 1 6 ” top side front 4 5/16 ” *10” transition used with dual, external and in ...

  • Zephyr AK7848ASX - page 11

    9 ELECTRICAL W ARNING All Electrical work must by performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...

  • Zephyr AK7848ASX - page 12

    10 www .zephyronline.com C/L C/L A B 12 3/8 ” min 30” 4” wood board fig. 2 fig. 1 Installation – Mounting the Range Hood 1. Measure distance from range top to hood bottom ( 30” min ) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. ( 12 3/8” from line A ) ( This is the top of the board used to hang th ...

  • Zephyr AK7848ASX - page 13

    11 CBI-600B AND PBI-1 100A BLOWER INST ALLA TION 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower pictured is a PBI-1 100A) 2. Connect male end of blower wire to female plug in the hood. (plug is located inside the hood behind the control panel) 3. Single Blower – ...

  • Zephyr AK7848ASX - page 14

    12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter . 2. Install threaded end of external blower wiring through external blower wiring knock out located inside the hood. 3. Place cap over threaded end of ...

  • Zephyr AK7848ASX - page 15

    13 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Features & Controls – Rocker Switch Controls ...

  • Zephyr AK7848ASX - page 16

    14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser . After cleaning, you m ...

  • Zephyr AK7848ASX - page 17

    15 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. I ...

  • Zephyr AK7848ASX - page 18

    T roubleshooting 16 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power co ...

  • Zephyr AK7848ASX - page 19

    17 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210009 Optional Accessories Single Internal Blower CBI-600B Dual Internal Blower PBI-1 100A External Blower CBE-1000 In-Line Blower PBN-1000A Vinyl Cover (36”) AK0636AB Vinyl Cover (42”) AK0642AB Vinyl Cover (48”) AK0648AB 12” Duct ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr AK7848ASX can be divided into several groups. They are, among others:
- Zephyr technical drawings
- AK7848ASX manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr AK7848ASX
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr AK7848ASX.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr AK7848ASX, service manual, brief instructions and user manuals Zephyr AK7848ASX. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr AK7848ASX.

A complete manual for the device Zephyr AK7848ASX, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr AK7848ASX by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr AK7848ASX.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr AK7848ASX - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr AK7848ASX, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr AK7848ASX, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr AK7848ASX - which should help us in our first steps of using Zephyr AK7848ASX
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr AK7848ASX
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr AK7848ASX in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr AK7848ASX?

Use the form below

If you did not solve your problem by using a manual Zephyr AK7848ASX, ask a question using the form below. If a user had a similar problem with Zephyr AK7848ASX it is likely that he will want to share the way to solve it.

Copy the text from the picture