Goodman Mfg GMH95の取扱説明書

15ページ 0.32 mb
ダウンロード

ページに移動 of 15

Summary
  • Goodman Mfg GMH95 - page 1

    C US ® RT6612018 Rev. 5 April 2010 GMH95 40" 95% Gas Furnace • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page ...

  • Goodman Mfg GMH95 - page 2

    PRODUCT IDENTIFICA TION 2 Minior Revision A 3 Description Air Flow Direction KBTUH AFUE Major Revision Maximum CFM @ 0.5" ESP 3 : 1200 4 : 1600 5 : 2000 Cabinet Width The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts inform ...

  • Goodman Mfg GMH95 - page 3

    PRODUCT IDENTIFICA TION 3 GMH950453BXA* GMH950703BXA* GMH950704CXA* GMH950904CXA* GMH950905DXA* GMH951155DXA* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“E ...

  • Goodman Mfg GMH95 - page 4

    4 PRODUCT DESIGN 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chart for details. 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90º Elbows, one close nipple, straight pipe. Right -- Straight pipe to reach gas valve. Access ...

  • Goodman Mfg GMH95 - page 5

    5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch 4 Gas Manifold 5 Combustion Air Intake Connection / “Coupling” 6 Hot Surface Igniter 7 Rollout Limit 8 Burners 9 Flame Sensor 1 0 Flue Pipe Connection / “Coupling” 1 1 Flue Pipe (Internal) 1 2 Primary Limit 1 3 Gas Line Entrance 1 4 F ...

  • Goodman Mfg GMH95 - page 6

    COMPONENT IDENTIFICA TION 6 GMH95*****XA* Cabinet Size A B C D E 13-5/ 8 17-1/ 2 20-7/ 8 All d imensions ar e in inches. 24-1/ 2 12-1/ 8 16 19-3/ 8 12-1 5/16 15-1 5/16 20-7/16 GMH950453B XA* GMH950703B XA* GM H950 704CX A* GM H950 904CX A* GM H950 905DX A* GM H951 155DX A* 16 19-1/ 2 23 17-1/ 2 21 RIGHT SIDE DRAIN LINE HOLES AIR INT AKE PIP E 2&quo ...

  • Goodman Mfg GMH95 - page 7

    7 PRODUCT DESIGN TRIP POIN T COIL COVER PRESSURE SWITCH COIL C OVER PRESSURE SWITCH PART # TRIP POI NT ID BLOWER PRESSURE SWITCH ID B LOWER PRESSURE SWITCH PART # TR IP POI NT COIL C OVER PRESSURE SWITCH TRIP POI NT ID BLOWER PRESSURE SWITCH HIGH ALTITUDE KIT GM H950453BXA* -1.30 -1. 10 -0.52 -0.37 -0.37 20197312 -1.10 0130F000 00P TBD TBD TBD GM H ...

  • Goodman Mfg GMH95 - page 8

    8 PRODUCT DESIGN P ar t N u mb er 10123514 o r 10123533 O pe n S e tt ing ( ° F ) 200 G M H 950453B XA * 1 G M H 950703B XA * 2 G M H 950704C XA * 2 G M H 950904C XA * 2 G M H 950905D XA * 2 G M H 951155D XA * 2 R O LLOUT LIMIT SW ITCH E S Par t Numbe r 101235 35 1012 3519 Open Setting (°F ) 150 160 GMH9 50453BX A* 1 GMH9 50703BX A* 1 GMH9 50704C ...

  • Goodman Mfg GMH95 - page 9

    9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GMH95 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 95%+ furnaces match up with the existing Amana ® brand coils ...

  • Goodman Mfg GMH95 - page 10

    10 PRODUCT DESIGN Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return air filters at the side and/or bottom return. The f ...

  • Goodman Mfg GMH95 - page 11

    FURNACE SPECIFICA TIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altit ...

  • Goodman Mfg GMH95 - page 12

    BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furn ace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooli ...

  • Goodman Mfg GMH95 - page 13

    BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 110 12 0 100 13 0 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU/H R x 1000 BTU OUTPUT vs T EMPERAT UR E RISE CHART T EM PER AT U R E R IS E 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU T = CFM x 1 .08 x RISE RISE = BTU OUTPUT 1.08 ÷ CFM 800 ...

  • Goodman Mfg GMH95 - page 14

    14 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAB GMH95[0703,0904,1 155]*XAC HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICING OR INS T ALLIN G THIS UNIT . M UL TIPL E POW ER SOURCES M A Y BE P RESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY ...

  • Goodman Mfg GMH95 - page 15

    15 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAC GMH95[0703,0904,1 155]*XAD R YL YELLO W OR O RAN GE PU PU RPLE GN G REEN BK BLACK BR BR OWN WH WH ITE BL BL U E GY GR A Y RD RED COLOR CO DES : LOW VOLT AGE (24V) LOW V OL T AG E FIEL D HI VOL TAG ...

メーカー Goodman Mfg カテゴリー Furnace

Goodman Mfg GMH95のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GMH95の取扱説明書
- Goodman Mfgの製品カード
- パンフレット
- またはGoodman Mfg GMH95の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Goodman Mfg GMH95の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Goodman Mfg GMH95の取り付け説明書、サービスマニュアル、簡易説明書、またはGoodman Mfg GMH95のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Goodman Mfg GMH95の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Goodman Mfg GMH95デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGoodman Mfg GMH95を使用するのを助ける技術的文書のことです。説明書は通常、全てのGoodman Mfg GMH95ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Goodman Mfgの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Goodman Mfg GMH95の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGoodman Mfg GMH95の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Goodman Mfg GMH95に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Goodman Mfg GMH95デバイスの基本機能を使うにあたってのヒント。 Goodman Mfg GMH95のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Goodman Mfg GMH95に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGoodman Mfg GMH95のメーカー/サービスへの連絡先に関する情報。

Goodman Mfg GMH95についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGoodman Mfg GMH95の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGoodman Mfg GMH95で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください