  • Goodman Mfg GMH95 - page 1

    C US ® RT6612018 Rev. 5 April 2010 GMH95 40" 95% Gas Furnace • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Model numbers listed on page ...

  • Goodman Mfg GMH95 - page 2

    PRODUCT IDENTIFICA TION 2 Minior Revision A 3 Description Air Flow Direction KBTUH AFUE Major Revision Maximum CFM @ 0.5" ESP 3 : 1200 4 : 1600 5 : 2000 Cabinet Width The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts inform ...

  • Goodman Mfg GMH95 - page 3

    PRODUCT IDENTIFICA TION 3 GMH950453BXA* GMH950703BXA* GMH950704CXA* GMH950904CXA* GMH950905DXA* GMH951155DXA* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“E ...

  • Goodman Mfg GMH95 - page 4

    4 PRODUCT DESIGN 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chart for details. 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90º Elbows, one close nipple, straight pipe. Right -- Straight pipe to reach gas valve. Access ...

  • Goodman Mfg GMH95 - page 5

    5 COMPONENT IDENTIFICA TION Upflow/Horizontal 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch 4 Gas Manifold 5 Combustion Air Intake Connection / “Coupling” 6 Hot Surface Igniter 7 Rollout Limit 8 Burners 9 Flame Sensor 1 0 Flue Pipe Connection / “Coupling” 1 1 Flue Pipe (Internal) 1 2 Primary Limit 1 3 Gas Line Entrance 1 4 F ...

  • Goodman Mfg GMH95 - page 6

    COMPONENT IDENTIFICA TION 6 GMH95*****XA* Cabinet Size A B C D E 13-5/ 8 17-1/ 2 20-7/ 8 All d imensions ar e in inches. 24-1/ 2 12-1/ 8 16 19-3/ 8 12-1 5/16 15-1 5/16 20-7/16 GMH950453B XA* GMH950703B XA* GM H950 704CX A* GM H950 904CX A* GM H950 905DX A* GM H951 155DX A* 16 19-1/ 2 23 17-1/ 2 21 RIGHT SIDE DRAIN LINE HOLES AIR INT AKE PIP E 2&quo ...

  • Goodman Mfg GMH95 - page 7

    7 PRODUCT DESIGN TRIP POIN T COIL COVER PRESSURE SWITCH COIL C OVER PRESSURE SWITCH PART # TRIP POI NT ID BLOWER PRESSURE SWITCH ID B LOWER PRESSURE SWITCH PART # TR IP POI NT COIL C OVER PRESSURE SWITCH TRIP POI NT ID BLOWER PRESSURE SWITCH HIGH ALTITUDE KIT GM H950453BXA* -1.30 -1. 10 -0.52 -0.37 -0.37 20197312 -1.10 0130F000 00P TBD TBD TBD GM H ...

  • Goodman Mfg GMH95 - page 8

    8 PRODUCT DESIGN P ar t N u mb er 10123514 o r 10123533 O pe n S e tt ing ( ° F ) 200 G M H 950453B XA * 1 G M H 950703B XA * 2 G M H 950704C XA * 2 G M H 950904C XA * 2 G M H 950905D XA * 2 G M H 951155D XA * 2 R O LLOUT LIMIT SW ITCH E S Par t Numbe r 101235 35 1012 3519 Open Setting (°F ) 150 160 GMH9 50453BX A* 1 GMH9 50703BX A* 1 GMH9 50704C ...

  • Goodman Mfg GMH95 - page 9

    9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GMH95 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 95%+ furnaces match up with the existing Amana ® brand coils ...

  • Goodman Mfg GMH95 - page 10

    10 PRODUCT DESIGN Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return air filters at the side and/or bottom return. The f ...

  • Goodman Mfg GMH95 - page 11

    FURNACE SPECIFICA TIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altit ...

  • Goodman Mfg GMH95 - page 12

    BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furn ace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooli ...

  • Goodman Mfg GMH95 - page 13

    BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 110 12 0 100 13 0 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU/H R x 1000 BTU OUTPUT vs T EMPERAT UR E RISE CHART T EM PER AT U R E R IS E 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU T = CFM x 1 .08 x RISE RISE = BTU OUTPUT 1.08 ÷ CFM 800 ...

  • Goodman Mfg GMH95 - page 14

    14 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAB GMH95[0703,0904,1 155]*XAC HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICING OR INS T ALLIN G THIS UNIT . M UL TIPL E POW ER SOURCES M A Y BE P RESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY ...

  • Goodman Mfg GMH95 - page 15

    15 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. GMH95[0453,0704,0905]*XAC GMH95[0703,0904,1 155]*XAD R YL YELLO W OR O RAN GE PU PU RPLE GN G REEN BK BLACK BR BR OWN WH WH ITE BL BL U E GY GR A Y RD RED COLOR CO DES : LOW VOLT AGE (24V) LOW V OL T AG E FIEL D HI VOL TAG ...

Manufacturer Goodman Mfg Category Furnace

Documents that we receive from a manufacturer of a Goodman Mfg GMH95 can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GMH95 manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GMH95
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GMH95.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GMH95, service manual, brief instructions and user manuals Goodman Mfg GMH95. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GMH95.

A complete manual for the device Goodman Mfg GMH95, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GMH95 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GMH95.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GMH95 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GMH95, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GMH95, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GMH95 - which should help us in our first steps of using Goodman Mfg GMH95
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GMH95
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GMH95 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GMH95?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GMH95, ask a question using the form below. If a user had a similar problem with Goodman Mfg GMH95 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)