Goodman Mfg GME8の取扱説明書

16ページ 0.3 mb
ダウンロード

ページに移動 of 16

Summary
  • Goodman Mfg GME8 - page 1

    C opyright ©2009-2010 Goodman Manufacturin g Company, L.P. RT6621020 Rev. 1 April 2010 GME8 33-3/8" 80% Gas Furnace Up flow/Horizont al • Refer to current Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appr ...

  • Goodman Mfg GME8 - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. Installation and repair of this unit should be performed ONLY by in- dividuals meeting the require- ments of an "entry level technicia ...

  • Goodman Mfg GME8 - page 3

    PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GME80703BXC* GME80905CXC* GME81155CXC* All models are low NOx models. The United States Environmental Protection Agency (“EPA”) has iss ...

  • Goodman Mfg GME8 - page 4

    4 PRODUCT DESIGN NOTE: Gas furnaces with induced draft blowers draw products of combustion through a heat exchanger allowing, in some instances, common venting with natural draft appliances (i.e. water heaters). All installations must be vented in accordance with National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition. In Canada, the furnaces m ...

  • Goodman Mfg GME8 - page 5

    5 PRODUCT DESIGN Accessibility Clearances (Minimum) Unobstructed front clearanace of 24" for servicing is rec- ommended. Top clearance for horizontal confirguration - 1" MINI M UM CL EARAN CE T O C OMBUST IBL E M AT E RIA LS - INCH E S SW B 10 3 C 6 1 1 ** Si ngl e Wal l V en t (S W) t o b e us ed o nly as a c o nn ec t o r. R e f e r to ...

  • Goodman Mfg GME8 - page 6

    PRODUCT DIMENSIONS 6 GME8*****XA UN I T S A B C D G ME 80 7 03 B X C * 1 7. 5 16 33 -3/ 8 28 G ME 80 905 CXC* G ME 81 155 CXC* 21 19 . 5 3 3- 3 / 8 2 8 A l l dim e n s ion s a re i n i nc he s . ...

  • Goodman Mfg GME8 - page 7

    7 PRODUCT DESIGN * All installas above 7,000 ft. require a pressure switch change. For installations in Canada, the GME8 furnace is certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.c.) Pa rt Nu m b e r 20 162 903 Op e n Set t i ng ( ° F) 16 0 G M E80 703 BXC* 1 G M E80 905 CXC* 1 G M E81 155 CXC* 1 PR I M ...

  • Goodman Mfg GME8 - page 8

    8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the new GME8 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 80% furnaces match up with the existing Amana ® brand coils ...

  • Goodman Mfg GME8 - page 9

    9 PRODUCT DESIGN Thermost at s: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This f ...

  • Goodman Mfg GME8 - page 10

    10 PRODUCT DESIGN Dual$aver Configuration & Operation Dual$aver This furnace is capable of the following heating modes: Single Stage (Factory Setting) Modifi ed T wo-Stage Fixed 5-Min Low Stage Auto T ime (1-12 Min) Low Stage T o change from the factory single-stage operation, adjust the dipswitches on the ignition control as follows: Off On M ...

  • Goodman Mfg GME8 - page 11

    FURNACE SPECIFICA TIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation . * For elevations above ...

  • Goodman Mfg GME8 - page 12

    BLOWER PERFORMANCE SPECIFICA TIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. 2. All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed. 3. For most jobs, about 400 CFM per ton when cooling is desirable. 4 . INSTALLATION IS TO BE ADJU ...

  • Goodman Mfg GME8 - page 13

    BLOWER PERFORMANCE SPECIFICA TIONS 13 30 40 50 60 70 80 90 11 0 120 100 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 OUTP UT BTU/ HR x 1 000 BTU OUTPUT vs T EMPERATURE RI SE CHA RT TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CFM x 1.08 x RISE RISE = BT U OUTPU T 1. 0 8 ÷ CFM 800 ...

  • Goodman Mfg GME8 - page 14

    14 WIRING DIAGRAMS HI GH V OL T AGE! DISC ONNECT ALL POWE R BEFORE SERVICI NG OR INS T ALLIN G THIS UNIT . MUL TIPL E POW ER SOURCES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUSE PROP ERTY DAMAG E, PERSONAL I NJURY OR DEA TH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A ...

  • Goodman Mfg GME8 - page 15

    15 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MUL TIPL E POW ER SOUR CES MA Y BE PRESENT . F A ILURE T O DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL INJURY OR DEA TH. GME8_CB BK (HI) A ...

  • Goodman Mfg GME8 - page 16

    16 SCHEMA TICS HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . MUL TIPL E POW ER SOUR CES MA Y BE PRESENT . F A ILURE T O DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL INJURY OR DEA TH . .00 05 3M K4 K2 HI HEAT COOL PARK CIR NEU K5 GAS V ALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR PROBE IGN ITOR FP IGN ...

メーカー Goodman Mfg カテゴリー Furnace

Goodman Mfg GME8のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GME8の取扱説明書
- Goodman Mfgの製品カード
- パンフレット
- またはGoodman Mfg GME8の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Goodman Mfg GME8の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Goodman Mfg GME8の取り付け説明書、サービスマニュアル、簡易説明書、またはGoodman Mfg GME8のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Goodman Mfg GME8の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Goodman Mfg GME8デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGoodman Mfg GME8を使用するのを助ける技術的文書のことです。説明書は通常、全てのGoodman Mfg GME8ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Goodman Mfgの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Goodman Mfg GME8の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGoodman Mfg GME8の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Goodman Mfg GME8に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Goodman Mfg GME8デバイスの基本機能を使うにあたってのヒント。 Goodman Mfg GME8のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Goodman Mfg GME8に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGoodman Mfg GME8のメーカー/サービスへの連絡先に関する情報。

Goodman Mfg GME8についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGoodman Mfg GME8の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGoodman Mfg GME8で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)