Lincoln Electric IM573の取扱説明書

32ページ 1.51 mb
ダウンロード

ページに移動 of 32

Summary
  • Lincoln Electric IM573 - page 1

    CALIBRA TION PROCEDURES IM573 September , 2002 PO WER W A VE PC BOARD REPLA CEMENT CALIBRA TION PROCEDURES Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OP ...

  • Lincoln Electric IM573 - page 2

    2 2 POWER W A VE CALIBRA TION INDEX OF PROCEDURES Capacitor discharge procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Setup after Display Board replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Display sensor calibration . . . . . . . . . ...

  • Lincoln Electric IM573 - page 3

    If the sensor calibration is not done, the display board may have some problems sensing the correct overlay on power up. The display is shipped with the water cooler disabled. If an internal water cooler is being used with the Power W ave, you must use the Setup Overlay L9660 to enable the water cooler before using the system. --------------------- ...

  • Lincoln Electric IM573 - page 4

    CAP ACITOR DISCHARGE PROCEDURE Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- trical shock, please observe all safety ...

  • Lincoln Electric IM573 - page 5

    POWER W A VE CALIBRA TION 5 5 CAP ACITOR DISCHARGE PROCEDURE (continued) CALIBRA TION TEST PROCEDURE 1. Remove main input supply power to the machine. 2. With the 3/8" nut driver , remove the scr ews that hold the handle to the machine. 3. Remove the rubber gasket (cover seal) from the lift bail. 4. With the 5/16" nut driver , remove the ...

  • Lincoln Electric IM573 - page 6

    POWER W A VE CALIBRA TION 6 6 CAP ACITOR DISCHARGE PROCEDURE (continued) FIGURE 2 – DISCHARGE LABEL D I S C H A R G E D I S C H A R G E D I S C H A R G E D I S C H A R G E D I S C H A R G E CALIBRA TION 9. Using the insulated, needle nose type jumper leads and insulated gloves, con- nect one jumper lead to one end of the resistor obtained in step ...

  • Lincoln Electric IM573 - page 7

    7 7 CAP ACITOR DISCHARGE PROCEDURE (continued) FIGURE 3 - RESISTOR WITH LEADS CONNECTED. CALIBRA TION 11. Check the voltage acr oss terminals #9 and #12 with the DC voltmeter . T erminal #9 has positive polarity and terminal #12 has negative polarity . V oltage should be zero. If any voltage remains, r epeat this capaci- tor dischar ge procedure. 1 ...

  • Lincoln Electric IM573 - page 8

    Setting up the SemiAutomatic Power W ave 450 after Display Board replacement After a Display board is installed, all users should veri- fy the polarity , sense lead and water cooler conditions. Proceed as follows: 1. Insert the SETUP Overlay (L9660) and turn the Power W ave on. 2. For the majority of applications, the wire feeder LED’s should loo ...

  • Lincoln Electric IM573 - page 9

    SENSOR CALIBRA TION TEST (FOR DISPLA Y BOARD) Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- trical shock, please obse ...

  • Lincoln Electric IM573 - page 10

    10 10 SENSOR CALIBRA TION TEST (FOR DISPLA Y BOARD) (continued) Figure 4 - SENSOR LOCA TION BEHIND OVERLA Y CALIBRA TION PROCEDURE 1. Insert the CALIBRA TION AND TEST overlay (L9660-255). If this overlay is not available, turn the machine ON with no overlay in place and refer to Figure 4 to identify the keys. The overlay ID number is momentarily di ...

  • Lincoln Electric IM573 - page 11

    SEMIAUTOMA TIC PW450 QUICK VOL T AGE CALIBRA TION Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- trical shock, please ...

  • Lincoln Electric IM573 - page 12

    12 12 SEMIAUTOMA TIC PW450 QUICK VOL T AGE CALIBRA TION (continued) Figure 5 - TEST AND CALIBRA TION OVERLA Y (32) (34) (36) (64) (33) (35) (37) (65) (67) (96) (97) (98) (99) (100) (101) (132) (133) (128) (130) (129) (131) CALIBRA TION PROCEDURE 1. Before changing or disturbing the defective display board, power up the machine with the L9660-255 T ...

  • Lincoln Electric IM573 - page 13

    CALIBRA TION 13 13 ROBOTIC PW450 QUICK VOL T AGE CALIBRA TION Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- trical sh ...

  • Lincoln Electric IM573 - page 14

    CALIBRA TION 14 14 POWER W A VE CALIBRA TION ROBOTIC PW450 QUICK VOL T AGE CALIBRA TION (continued) Figure 5 - TEST AND CALIBRA TION OVERLA Y (32) (34) (36) (64) (33) (35) (37) (65) (67) (96) (97) (98) (99) (100) (101) (132) (133) (128) (130) (129) (131) PROCEDURE 1. Before changing or disturbing the defective display board, power up the machine wi ...

  • Lincoln Electric IM573 - page 15

    SEMIAUTOMA TIC PW450 FULL VOL T AGE CALIBRA TION Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- trical shock, please o ...

  • Lincoln Electric IM573 - page 16

    PROCEDURE 1. The voltage calibration numbers ar e stored in the display board. They ar e program- mable from the fr ont panel using the T est and Calibration Overlay . 2. Change the PC board in question. 3. Install the T est and Calibration Overlay L9660-255 and power up the machine. See Figure 6. 4. Press the V oltage Calibration function (32). Th ...

  • Lincoln Electric IM573 - page 17

    CALIBRA TION 17 17 POWER W A VE CALIBRA TION ROBOTIC PW450 FULL VOL T AGE CALIBRA TION Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and ...

  • Lincoln Electric IM573 - page 18

    CALIBRA TION 18 18 POWER PROCEDURE 1. The voltage calibration numbers ar e stored in the display board. They ar e program- mable from the fr ont panel using the T est and Calibration Overlay . 2. Change the PC board in question. 3. Install the T est and Calibration Overlay L9660-255 and power up the machine. See Figure 6. 4. Press the V oltage Cali ...

  • Lincoln Electric IM573 - page 19

    SEMIAUTOMA TIC PW450 FULL VOL T AGE CALIBRA TION USING A WELDING ARC Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- tr ...

  • Lincoln Electric IM573 - page 20

    20 20 SEMIAUTOMA TIC PW450 FULL VOL T AGE CALIBRA TION USING A WELDING ARC (continued) Figure 7 - TEST AND CALIBRA TION OVERLA Y (32) (34) (36) (64) (33) (35) (37) (65) (67) (96) (97) (98) (99) (100) (101) (132) (133) (128) (130) (129) (131) CALIBRA TION PROCEDURE 1. The voltage calibration numbers ar e stored in the display board. They ar e progra ...

  • Lincoln Electric IM573 - page 21

    21 21 SEMIAUTOMA TIC PW450 FULL VOL T AGE CALIBRA TION USING A WELDING ARC (continued) CALIBRA TION – POLARITY (+21A) + POLARITY – POLARITY NOTE: Do not attempt to weld for –Polarity (+21A). Set the number to the same as recor ded for +Polarity (+67A). Also for +Polarity and –Polarity , move the volt- meter sense lead from the conductor blo ...

  • Lincoln Electric IM573 - page 22

    SEMIAUTOMA TIC PW450 CURRENT CALIBRA TION Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avoid elec- trical shock, please observe ...

  • Lincoln Electric IM573 - page 23

    23 23 SEMIAUTOMA TIC PW450 CURRENT CALIBRA TION (continued) CALIBRA TION 2. Locate the 10 tur n trimmer potentiometer located on the control boar d. It is the only trimmer on the board. If the trimmer is not accessible with the control boar d installed, then the board must be r emoved and laid on the top of the PC board compartment. Be sure the con ...

  • Lincoln Electric IM573 - page 24

    24 24 SEMIAUTOMA TIC PW450 CURRENT CALIBRA TION (continued) CALIBRA TION PROCEDURE 1. Install the T est and Calibration Overlay and apply power to the machine. See Figure 10. 2. Press the Manual Pr ocedure Entry Key (64). The machine should display the following: PROCESS 1 SETUP 1-0 3. T oggle the Arrow Keys (100 and 101) until the display reads: P ...

  • Lincoln Electric IM573 - page 25

    CALIBRA TION 25 25 POWER W A VE CALIBRA TION ROBOTIC PW450 CURRENT CALIBRA TION Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in danger to the technician or machine operator and will invalidate your factory warranty . For your safety and to avo ...

  • Lincoln Electric IM573 - page 26

    CALIBRA TION 26 26 POWER W A VE CALIBRA TION ROBOTIC PW450 CURRENT CALIBRA TION (continued) 2. Locate the 10 tur n trimmer potentiometer located on the control boar d. It is the only trimmer on the board. If the trimmer is not accessible with the control boar d installed, then the board must be r emoved and laid on the top of the PC board compartme ...

  • Lincoln Electric IM573 - page 27

    CALIBRA TION 27 27 POWER ROBOTIC PW450 CURRENT CALIBRA TION (continued) PROCEDURE 1. Install the T est and Calibration Overlay and apply power to the machine. See Figure 10. 2. Press the Manual Pr ocedure Entry Key (64). The machine should display the following: PROCESS 1 SETUP 1-0 3. T oggle the Arrow Keys (100 and 101) until the display reads: PR ...

  • Lincoln Electric IM573 - page 28

    The Power W ave 450 Robotic may be triggered inde- pendent of the robot using the following circuit and pro- cedure. 1. Remove the large connector plug on the rear of the PW450. (As viewed from the front of the machine). 2. Connect a normally open switch and a 24VDC sup- ply either to the large connector plug (P82) or to the harness connectors on t ...

  • Lincoln Electric IM573 - page 29

    CALIBRA TION 29 29 POWER W A VE CALIBRA TION ROBOTIC INTERF ACE P .C. BOARD CALIBRA TION Position Interface board on top of the power wave so that the component side is up. Make certain a non-con- ductive insulating material is protecting the control board from touching any conductive surface. Locate the J109 receptacle. Directly next to the recept ...

  • Lincoln Electric IM573 - page 30

    ROBOTIC INTERF ACE CONNECTIONS 30 30 POWER W A VE CALIBRA TION ARCTOOL WELDING INPUTS AND OUT- PUTS J101-1 +Serial loop CTRL J27-1 J101-2 High speed sense 1 P83-K J101-3 High speed sense 2 P83-L J101-4 -Serial loop CTRL J27-4 J104-1 V oltage signal CTRL J21-4 J104-2 Current signal CTRL J21-7 J104-3 W ater PWR D.K. J16-4 J104-4 +output signal SNUB J ...

  • Lincoln Electric IM573 - page 31

    TEST PROCEDURE AFTER REP AIR 31 31 POWER W A VE CALIBRA TION The following five steps should be completed after examining and or repairing a Power W ave 450R. These steps will insure that all aspects and systems of the Power W ave are functioning. This procedure does not include fan operation, or proper water cooler operation, both of which are ind ...

  • Lincoln Electric IM573 - page 32

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .lincolnelectric.com • World's Leader in W elding and Cutting Products • ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric IM573のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IM573の取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric IM573の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric IM573の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric IM573の取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric IM573のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric IM573の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lincoln Electric IM573デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric IM573を使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric IM573ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric IM573の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric IM573の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric IM573に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric IM573デバイスの基本機能を使うにあたってのヒント。 Lincoln Electric IM573のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric IM573に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric IM573のメーカー/サービスへの連絡先に関する情報。

Lincoln Electric IM573についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric IM573の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric IM573で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)