  • Omega Engineering OS1592 - page 1

    OS1592 Infrared Fiber Optic Thermometer/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at U ser ’ s Guide ...

  • Omega Engineering OS1592 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega Engineering OS1592 - page 3

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s custo ...

  • Omega Engineering OS1592 - page 4

    T ABLE OF CONTENTS SECTION ..................................................................P AGE Section 1 Introduction ........................................................................ 1 Section 2 Installation ........................................................................... 1 2.1 Unpacking ...................................... ...

  • Omega Engineering OS1592 - page 5

    T ABLE OF FIGURES FIGURE ..................................................................P AGE 1 OS1592 Main Unit ............................................................................ 3 2 Power Supply and Analog Output Connections ........................... 3 3 V isual Functional Flow Chart ................................................ ...

  • Omega Engineering OS1592 - page 6

    INTRODUCTION The new OS1592 series Infrared Fiber Optic Thermometer/T ransmitter provides non-contact temperatur e measurement for industrial applications. The unit measures temperatur e starting at 260°C (500°F) and up to 2482°C (4500°F). It provides dual analog outputs (4-20 mA, 0-5 VDC, 0-10 VDC, 1 mV/Deg, J & K type T/Cs) electrically i ...

  • Omega Engineering OS1592 - page 7

    The following describes the ordering information: The unit provides two separate analog outputs. The first is 1mV/Deg (Standard). The second analog output to be specified as follows : - * , where, - mA , 4-20 mA output - V1, 0/5 VDC output - V2, 0/10 VDC output - K, Thermocouple output, K type (For R1 & R2 T emperature range only) - J , Thermoc ...

  • Omega Engineering OS1592 - page 8

    2.2 – Electrical Connection Attach the optical assembly to the optical adapter located on the side of the housing. Refer to Fig. 1 for the overall appearance of the unit. Open the cover of the aluminum housing. Slide your cable through the metal feed thru and connect the wir es to the 9 position terminal block (J101) as shown in Fig. 2. Depending ...

  • Omega Engineering OS1592 - page 9

    OPERA TION T able 1 shows all the display modes of the model OS1592, as well as all the functions of the membrane keypad. Fig 3 shows the V isual Functional flow chart of the display . Table 1 - Functional Flow Chart Figure 3 - Visual Functional Flow Chart OS1592 Infrared Fiber Optic Thermometer/T ransmitter 3 4 DISPLA Y MODE: Press to... Go to Go ...

  • Omega Engineering OS1592 - page 10

    The Emissivity setting as well as the temperature Engineering unit (°F or °C) are stored in the non-volatile memor y . Removing the main power will not erase or change these settings. 3.1 - Changing the T emperature from °F to °C (or vice versa) Press the key to go to either the MAX , MIN, or DIF display mode. Press the key to change the temper ...

  • Omega Engineering OS1592 - page 11

    0-5VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 5 0-10VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 10 Where, T1 is the minimum temperature range T2 is the maximum temperature range 3.5 - Resetting T emperature V alues The calculated temperature values (Min, Max, and Dif f) can be reset at any time by pressing the ...

  • Omega Engineering OS1592 - page 12

    Figure 5 - Optical Lens Assembly (L1) .25" @ 8" FOV Figure 6 - Optical Lens Assembly (L1) .19" @ 20" FOV Figure 7 - Optical Lens Assembly (L1) .076" @ 6" FOV Figure 8 - Ceramic Tip Assembly (L2) OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 7 111 (4.38) 159 (6.25) Dimensions mm (in.) FIBER 19 (.75) DIA. 25.4 (1 ...

  • Omega Engineering OS1592 - page 13

    Figure 9 - Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting Figure 10 - Optical Head, Mounting Bracket OS1592-MB Figure 11 - Air Purge Collar OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 8 FIBER 72 (2.84) 53 ± 1.5 (2.10 ± 0.06) 12.7 ± 1.5 (.50 ± 0.06) 11 (0.438) 102 ± 1.5 4.00 ± 0.06 25.4 ± 1.5 (1.00 ± .06) FULL THREAD ...

  • Omega Engineering OS1592 - page 14

    SPECIFICA TIONS T emperature Range R1 260 to 538°C (500 to 1000°F) R2 538 to 1093°C (1000 to 2000°F) R3 1093 to 2482°C (2000 to 4500°F) Accuracy at 22°C (72 °F) 1% of Rdg. ambient temperature and at Emissivity of 0.95 or greater Repeatability 0.5% of Rdg Resolution 1°C or 1°F Response T ime 25 msec (0 to 63% of Final value) Spectral Respo ...

  • Omega Engineering OS1592 - page 15

    Display Backlit LCD dual display Keypad switch 4 position, tactile feed back membrane Electrical Isolation Between Input supply and Analog outputs, 1000 V AC Calculated T emperature Maximum (MAX), Minimum (MIN) values and Differ ential (DIF), Reset via keypad High Alarm LED & Display Icon indication Set & enabled via Keypad Alarm set point ...

  • Omega Engineering OS1592 - page 16

    OS1592 Infrared Fiber Optic Thermometer/T ransmitter 5 11 MAINTENANCE Routine maintenance is not requir ed except for periodic re-calibration, occasional inspection of the input and output ends of the fiber assembly for cleanliness, and a check for broken fibers if damage is suspected. The optical fibers will provide satisfactory service indefinite ...

  • Omega Engineering OS1592 - page 17

    OS1592 Infrared Fiber Optic Thermometer/Transmitter Addendum 12 Safety W arnings and IEC Symbols This device is marked with international safety and hazardous symbols in accordance with IEC1010. It is important to r ead and follow all the precautions and instructions in this manual befor e operating or commissioning this device as it contains impor ...

  • Omega Engineering OS1592 - page 18

    M3672/0905 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Contr ...

メーカー Omega Engineering カテゴリー Thermometer

Omega Engineering OS1592のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OS1592の取扱説明書
- Omega Engineeringの製品カード
- パンフレット
- またはOmega Engineering OS1592の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega Engineering OS1592の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega Engineering OS1592の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega Engineering OS1592のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega Engineering OS1592の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega Engineering OS1592デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega Engineering OS1592を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega Engineering OS1592ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omega Engineeringの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega Engineering OS1592の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega Engineering OS1592の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega Engineering OS1592に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega Engineering OS1592デバイスの基本機能を使うにあたってのヒント。 Omega Engineering OS1592のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega Engineering OS1592に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega Engineering OS1592のメーカー/サービスへの連絡先に関する情報。

Omega Engineering OS1592についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega Engineering OS1592の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega Engineering OS1592で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)