Manual Omega Engineering OS1592

18 pages 0.25 mb
Download

Go to site of 18

Summary
  • Omega Engineering OS1592 - page 1

    OS1592 Infrared Fiber Optic Thermometer/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at U ser ’ s Guide ...

  • Omega Engineering OS1592 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega Engineering OS1592 - page 3

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s custo ...

  • Omega Engineering OS1592 - page 4

    T ABLE OF CONTENTS SECTION ..................................................................P AGE Section 1 Introduction ........................................................................ 1 Section 2 Installation ........................................................................... 1 2.1 Unpacking ...................................... ...

  • Omega Engineering OS1592 - page 5

    T ABLE OF FIGURES FIGURE ..................................................................P AGE 1 OS1592 Main Unit ............................................................................ 3 2 Power Supply and Analog Output Connections ........................... 3 3 V isual Functional Flow Chart ................................................ ...

  • Omega Engineering OS1592 - page 6

    INTRODUCTION The new OS1592 series Infrared Fiber Optic Thermometer/T ransmitter provides non-contact temperatur e measurement for industrial applications. The unit measures temperatur e starting at 260°C (500°F) and up to 2482°C (4500°F). It provides dual analog outputs (4-20 mA, 0-5 VDC, 0-10 VDC, 1 mV/Deg, J & K type T/Cs) electrically i ...

  • Omega Engineering OS1592 - page 7

    The following describes the ordering information: The unit provides two separate analog outputs. The first is 1mV/Deg (Standard). The second analog output to be specified as follows : - * , where, - mA , 4-20 mA output - V1, 0/5 VDC output - V2, 0/10 VDC output - K, Thermocouple output, K type (For R1 & R2 T emperature range only) - J , Thermoc ...

  • Omega Engineering OS1592 - page 8

    2.2 – Electrical Connection Attach the optical assembly to the optical adapter located on the side of the housing. Refer to Fig. 1 for the overall appearance of the unit. Open the cover of the aluminum housing. Slide your cable through the metal feed thru and connect the wir es to the 9 position terminal block (J101) as shown in Fig. 2. Depending ...

  • Omega Engineering OS1592 - page 9

    OPERA TION T able 1 shows all the display modes of the model OS1592, as well as all the functions of the membrane keypad. Fig 3 shows the V isual Functional flow chart of the display . Table 1 - Functional Flow Chart Figure 3 - Visual Functional Flow Chart OS1592 Infrared Fiber Optic Thermometer/T ransmitter 3 4 DISPLA Y MODE: Press to... Go to Go ...

  • Omega Engineering OS1592 - page 10

    The Emissivity setting as well as the temperature Engineering unit (°F or °C) are stored in the non-volatile memor y . Removing the main power will not erase or change these settings. 3.1 - Changing the T emperature from °F to °C (or vice versa) Press the key to go to either the MAX , MIN, or DIF display mode. Press the key to change the temper ...

  • Omega Engineering OS1592 - page 11

    0-5VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 5 0-10VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 10 Where, T1 is the minimum temperature range T2 is the maximum temperature range 3.5 - Resetting T emperature V alues The calculated temperature values (Min, Max, and Dif f) can be reset at any time by pressing the ...

  • Omega Engineering OS1592 - page 12

    Figure 5 - Optical Lens Assembly (L1) .25" @ 8" FOV Figure 6 - Optical Lens Assembly (L1) .19" @ 20" FOV Figure 7 - Optical Lens Assembly (L1) .076" @ 6" FOV Figure 8 - Ceramic Tip Assembly (L2) OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 7 111 (4.38) 159 (6.25) Dimensions mm (in.) FIBER 19 (.75) DIA. 25.4 (1 ...

  • Omega Engineering OS1592 - page 13

    Figure 9 - Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting Figure 10 - Optical Head, Mounting Bracket OS1592-MB Figure 11 - Air Purge Collar OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 8 FIBER 72 (2.84) 53 ± 1.5 (2.10 ± 0.06) 12.7 ± 1.5 (.50 ± 0.06) 11 (0.438) 102 ± 1.5 4.00 ± 0.06 25.4 ± 1.5 (1.00 ± .06) FULL THREAD ...

  • Omega Engineering OS1592 - page 14

    SPECIFICA TIONS T emperature Range R1 260 to 538°C (500 to 1000°F) R2 538 to 1093°C (1000 to 2000°F) R3 1093 to 2482°C (2000 to 4500°F) Accuracy at 22°C (72 °F) 1% of Rdg. ambient temperature and at Emissivity of 0.95 or greater Repeatability 0.5% of Rdg Resolution 1°C or 1°F Response T ime 25 msec (0 to 63% of Final value) Spectral Respo ...

  • Omega Engineering OS1592 - page 15

    Display Backlit LCD dual display Keypad switch 4 position, tactile feed back membrane Electrical Isolation Between Input supply and Analog outputs, 1000 V AC Calculated T emperature Maximum (MAX), Minimum (MIN) values and Differ ential (DIF), Reset via keypad High Alarm LED & Display Icon indication Set & enabled via Keypad Alarm set point ...

  • Omega Engineering OS1592 - page 16

    OS1592 Infrared Fiber Optic Thermometer/T ransmitter 5 11 MAINTENANCE Routine maintenance is not requir ed except for periodic re-calibration, occasional inspection of the input and output ends of the fiber assembly for cleanliness, and a check for broken fibers if damage is suspected. The optical fibers will provide satisfactory service indefinite ...

  • Omega Engineering OS1592 - page 17

    OS1592 Infrared Fiber Optic Thermometer/Transmitter Addendum 12 Safety W arnings and IEC Symbols This device is marked with international safety and hazardous symbols in accordance with IEC1010. It is important to r ead and follow all the precautions and instructions in this manual befor e operating or commissioning this device as it contains impor ...

  • Omega Engineering OS1592 - page 18

    M3672/0905 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Contr ...

Manufacturer Omega Engineering Category Thermometer

Documents that we receive from a manufacturer of a Omega Engineering OS1592 can be divided into several groups. They are, among others:
- Omega Engineering technical drawings
- OS1592 manuals
- Omega Engineering product data sheets
- information booklets
- or energy labels Omega Engineering OS1592
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega Engineering OS1592.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega Engineering OS1592, service manual, brief instructions and user manuals Omega Engineering OS1592. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega Engineering OS1592.

A complete manual for the device Omega Engineering OS1592, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega Engineering OS1592 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega Engineering OS1592.

A complete Omega Engineering manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega Engineering OS1592 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega Engineering OS1592, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega Engineering OS1592, that we can find in the current document
3. Tips how to use the basic functions of the device Omega Engineering OS1592 - which should help us in our first steps of using Omega Engineering OS1592
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega Engineering OS1592
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega Engineering OS1592 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega Engineering OS1592?

Use the form below

If you did not solve your problem by using a manual Omega Engineering OS1592, ask a question using the form below. If a user had a similar problem with Omega Engineering OS1592 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)