    Summary 1 INSTRUCTIONS FOR SAFE AND PROPER USE _______________ 20 2 POSITIONING OF THE HOB _______________________________ 22 3 ADJUSTMENT TO DIFFERENT TYPES OF GAS _______________ 28 4 FINAL OPERATIONS _____________________________________ 30 5 USING THE HOB ________________________________________ 31 6 CLEANING AND MAINTENANCE ___________________ ...

  • Smeg PGF75SC3 - page 2

    Introduction 1 INSTR UCTIONS FOR SAFE AND PR OPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS EN TIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE HOB. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATI ...

  • Smeg PGF75SC3 - page 3

    Introduction THE APPLIANCE DATA PLATE, WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME, IS POSITIONED AT A VISIBLE POINT UNDER THE SAFETY COVER. THE DATA PLATE ON THE PROTECTIVE COVER MUST NEVER BE REMOVED . DO NOT PUT PANS WITHOUT PERFECTLY PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB PANSTAND GRIDS. DO NOT USE COOKING RECEPTACLES THAT EXT ...

  • Smeg PGF75SC3 - page 4

    Instructions for the installer 22 2 POSITIONING OF THE HOB The following operation requires buildi ng and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminat ed wood, as long as they are heat- resistant (T 90°C). 2.1 Attachment ...

  • Smeg PGF75SC3 - page 5

    Instructions for the installer 2.2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figure in the work surface, observing a minimum distance of 50 mm from the rear edge. 1) The lower part of the protective cover must be fully accessible when the appliance is installed. This appliance can be in ...

  • Smeg PGF75SC3 - page 6

    Instructions for the installer 24 Important: Other types of installation will only be possible under th e manufacturer's supervision. Overall dimensions: location of gas and electrical connection points (all measures in mm). Warning: the bottom surface of the hob can become very hot. To avoid a hazard, under-bench access must be restricted. Re ...

  • Smeg PGF75SC3 - page 7

    Instructions for the installer 2.3 Electrical connection Make sure that the voltage and capacit y of the power supply cable conform to the data shown on the plate loca ted under the protective cover. Do not remove this plat e for any reason . The power supply cable plug and the wa ll socket must be of the same type and conform to the current electr ...

  • Smeg PGF75SC3 - page 8

    Instructions for the installer 26 2.4 Ventilation requirements The appliance may be installed only in rooms with permanent ventilation, as required by standards regolations in force. The room in which the appliance is installed must have sufficient air flow to satisfy the requirements of normal gas combus tion and of necessary air exchange in the r ...

  • Smeg PGF75SC3 - page 9

    Instructions for the installer 2.6 Gas connection Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe conforming to the prov isions defined by standard regolations in force. After connection operations, check for leaks using a soapy solution. The hob has been inspected for G20 natural gas (2H) at a pressure of 2 ...

  • Smeg PGF75SC3 - page 10

    Instructions for the installer 28 3 ADJUSTMENT T O DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, unplug th e appliance from the mains. The hob is set for natural gas G20 (2H) at a pressure of 20 mbar. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjust ed on ...

  • Smeg PGF75SC3 - page 11

    Instructions for the installer 3.2 Burner and nozzle characteristics table Burner Rated heating capacity (kW) LPG – G30/G31 30/37 mbar Nozzle diameter 1/100 mm By-pass mm 1/100 Reduced flow rate (W) Flow rate g/h G30 Flow rate g/h G31 Auxiliary (1) 1.05 50 30 * 27/28 ** 400 76 75 Semi rapid (2) 1.75 63 30 * 32/33 ** 500 127 125 Ultra Rapid (3) 4. ...

  • Smeg PGF75SC3 - page 12

    Instructions for the installer 30 4 FINAL OPERA TIONS After carrying out the above adjustments, remount in reverse order to the instructions given in paragraph “3.1 Replacement of nozzles on the hob”. After having regulated the device wit h gas other than the one tested, replace the label located on the guar d with the one that corresponds to t ...

  • Smeg PGF75SC3 - page 13

    Instructions for the user 5 USING THE HOB 5.1 Ignition of the burners Before turning on the burners, make su re that the flame-spreader crowns and respective caps are properly fi tted in their housings. Ensure the flame-spreader holes A are aligned with the ignition plugs and the thermocouples. Panstand grid B , available upon request, is intended ...

  • Smeg PGF75SC3 - page 14

    Instructions for the user 32 5.2 Practical advice for using the burners For better use of the burners and lowe r gas consumption, use covered cooking receptacles that have a flat, smooth bottom and are proportional in size to the burner to prevent the flame from licking the sides (see paragraph “ 5.3 Diameter of receptacles ”). When water reach ...

  • Smeg PGF75SC3 - page 15

    Instructions for the user 6 CLEANING AND MAINTENANCE Before any intervention, disconnect the appliance from the mains. Never use a steam jet to clean the appliance. 6.1 Cleaning the stainless steel To keep stainless steel in good c ondition it should be cleaned regularly after use. Let it cool first. 6.1.1 Routine daily cleaning To clean and preser ...

  • Smeg PGF75SC3 - page 16

    Instructions for the user 34 In models with central pan stand, fit this piece, taking care that its centre is perfectly aligned with the centre of the burner ...

メーカー Smeg カテゴリー Stove

Smeg PGF75SC3のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- PGF75SC3の取扱説明書
- Smegの製品カード
- パンフレット
- またはSmeg PGF75SC3の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Smeg PGF75SC3の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Smeg PGF75SC3の取り付け説明書、サービスマニュアル、簡易説明書、またはSmeg PGF75SC3のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Smeg PGF75SC3の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Smeg PGF75SC3デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSmeg PGF75SC3を使用するのを助ける技術的文書のことです。説明書は通常、全てのSmeg PGF75SC3ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Smegの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Smeg PGF75SC3の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSmeg PGF75SC3の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Smeg PGF75SC3に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Smeg PGF75SC3デバイスの基本機能を使うにあたってのヒント。 Smeg PGF75SC3のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Smeg PGF75SC3に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSmeg PGF75SC3のメーカー/サービスへの連絡先に関する情報。

Smeg PGF75SC3についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSmeg PGF75SC3の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSmeg PGF75SC3で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)