    Instructions – Parts List GRACO INC. P .O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001 2:1 Ratio Monark R Pump 200 psi (1.4 MPa, 14 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure Part No. 223185, Series C 55 Gallon (200 Liter) Drum Size, UHMWPE and Lea ...

  • Graco 223185 Series C - page 2

    2 307985 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. W ARNING EQUIPMENT MISUSE HAZARD Equipment misuse can c ...

  • Graco 223185 Series C - page 3

    307985 3 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using ...

  • Graco 223185 Series C - page 4

    4 307985 Notes ...

  • Graco 223185 Series C - page 5

    307985 5 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor . If you supply your own accessories, be sure they are ade- quately sized and pressure rate ...

  • Graco 223185 Series C - page 6

    6 307985 Installation 06089 Fig. 2 KEY A Bleed-T ype Master Air V alve (required, for pump) B Air Filter/Regulator C Air Line Lubricator D Fluid Drain V alve (required) E Surge T a nk F Fluid Shutoff V alves G Fluid Filter H Fluid Pressure Regulator J Air Spray Gun K Back Pressure Regulator L Pump M Air Supply Line N Bleed-T ype Master Air V alves ...

  • Graco 223185 Series C - page 7

    307985 7 Installation A vailable Accessories (must be purchased separately) Air Line Accessories W ARNING A bleed-type master air valve (A) is required in your system to help reduce the risk of serious injury , including splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjust- ing or repairing the pump. The ble ...

  • Graco 223185 Series C - page 8

    8 307985 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally . T o reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or moving parts, follow the Pressure Relief Proce- dure whenever you ...

  • Graco 223185 Series C - page 9

    307985 9 Operation Prime the Pump 1. See Fig. 2. Remove the spray nozzle from the gun. See the gun instruction manual. 2. Close all bleed-type air valves (A, N). 3. Close the pump air filter/regulator (B). 4. Close the fluid drain valve (D). 5. Check that all fittings throughout the system are tightened securely . 6. Connect the air supply line to ...

  • Graco 223185 Series C - page 10

    10 307985 Notes ...

  • Graco 223185 Series C - page 11

    307985 1 1 Maintenance Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the ...

  • Graco 223185 Series C - page 12

    12 307985 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Relieve the pressure. 2. Check all possible problems and solutions before disassembling pump. Problem Cause Solution Pump fails to operate. Restricted line or inadequate ...

  • Graco 223185 Series C - page 13

    307985 13 Service Disconnecting the Displacement Pump NOTE: For displacement pump repair instructions, refer to the separate displacement pump manual 307983, supplied. W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Flush the pump if possible. ...

  • Graco 223185 Series C - page 14

    14 307985 Parts Model 223185, Series C 2:1 Ratio Monark Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, Monark See 307043 for parts 1 3 223177 PUMP , displacement; used on Model 223185 See 307983 for parts 1 4 19161 1 ROD, connecting; 19.54 in. (496.3 mm) long 1 6 100579 PIN, cot ...

  • Graco 223185 Series C - page 15

    307985 15 Parts Model 223186, Series C 2:1 Ratio Monark Pump, Stubby Size; UHMWPE and Leather Packed Ref Part No. No. Description Qty 1 206955 AIR MOTOR, Monark See 307043 for parts 1 3 223177 PUMP , displacement; used on Model 223186 See 307983 for parts 1 4 191736 ROD, connecting; 6.98 in. (177.3 mm) long 1 6 100579 PIN, cotter 1 7 162648 LOCKWAS ...

  • Graco 223185 Series C - page 16

    16 307985 Dimensions 06085 A B C Model No. A B C 223185 47.81 in. (1215 mm) 15.31 in. (389 mm) 32.5 in. (826 mm) 223186 35.31 in. (897 mm) 15.31 in. (389 mm) 20 in. (508 mm) Mounting Hole Layout 2.254 in. (57.25 mm) 5.250 in. (133.4 mm) 0.375 in. (9.52 mm) diameter 2.625 in. (66.67 mm) 3.188 in. (80.97 mm) NOTE: Use mounting gasket 161322. 1 in. np ...

  • Graco 223185 Series C - page 17

    307985 17 T echnical Data Category Data Ratio 2:1 Maximum fluid working pressure 200 psi (14 bar) Maximum air input pressure 100 psi (7 bar) Pump cycles per 1 gallon (3.8 liters) 11 Fluid flow at 60 cycles per minute 5.5 gpm (21 liters/min) Fluid inlet size 1–1/2 npt(f) Fluid outlet size 1 in. npt(f) Air inlet size 3/8 npsm(f) Weight 40 lb (18.14 ...

  • Graco 223185 Series C - page 18

    18 307985 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from the ...

メーカー Graco カテゴリー Marine Sanitation System

Graco 223185 Series Cのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 223185 Series Cの取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 223185 Series Cの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 223185 Series Cの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 223185 Series Cの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 223185 Series Cのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 223185 Series Cの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 223185 Series Cデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 223185 Series Cを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 223185 Series Cユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 223185 Series Cの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 223185 Series Cの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 223185 Series Cに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 223185 Series Cデバイスの基本機能を使うにあたってのヒント。 Graco 223185 Series Cのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 223185 Series Cに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 223185 Series Cのメーカー/サービスへの連絡先に関する情報。

Graco 223185 Series Cについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 223185 Series Cの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 223185 Series Cで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)