Danby DKC445BL - page 1
Model • Modèle• Modelo DKC445BL For service, contact your nearest service depot or call: 1-800-26- Danby (1-800-263-2629) to recommend a depot in your area. En cas de réparation, veuillez contacter votre service après-vente le plus près ou communiquez au: 1-800-26- Danby (1-800-263-2629) pour connaître le service après-vente le plus proch ...
-
Danby DKC445BL - page 2
OWNER’S MANUAL MANUEL D'UTILISATION MANUAL DEL PROPIETARIO Model • Modèle• Modelo DKC445BL CAUTION: Read and follow all safety rules and operating instructions before first use of this product. PRÉCAUTION: V euillez lire attentivement les consignes de sécurité et les instructions d'utilisation avant l'utilisation initiale d ...
-
Danby DKC445BL - page 3
T ABLE OF CONTENTS Before putting appliance into use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 W e care for the environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 T ips for energy savings . . . . . . . . . . . . . . . . . . ...
-
Danby DKC445BL - page 4
2 BEFORE PUTTING APPLIANCE INTO USE • Before connecting the appliance to any electrical power supply, leave it standing (upright) for about 2 hours. This will reduce the possibility of malfunctions in the cooling system due to transport handling. • Clean the appliance thoroughly, both interior and exterior. (See Cleaning and Maintenance) WE CAR ...
-
Danby DKC445BL - page 5
3 Instructions pertaining to the risk of fire, electric shock, or injury to persons. GROUNDING INSTRUCTIONS For your personal safety, this appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped w ...
-
Danby DKC445BL - page 6
1 Chrome Rail (for attachment to Worktop) 4 Self-Tapping Screws (to attach chrome rail) 1 CO2 Cylinder Support Stand 1 CO2 Cylinder (empty) 1 CO2 Regulator (high/low pressure gauges) 1 CO2 Air Line Hose (red) 2 CO2 Air Line Hose Connectors (black) 1 Beer Keg Coupler 1 Beer T ower Unit (complete with faucet, hose and wing nut) 1 Rubber Washer (to be ...
-
Danby DKC445BL - page 7
CHILL'N TAP ASSEMBL Y INSTRUCTIONS: 5 1. Remove Worktop: Using a Phillips Screwdriver, remove the three screws located on the front underside edge of the worktop and the three screws located at the rear (back) side of the worktop. See Fig's. 1 & 2 Remove the worktop from the cabinet and position the worktop on top of the cabinet so th ...
-
Danby DKC445BL - page 8
6 CHILL'N TAP ASSEMBL Y INSTRUCTIONS CON’T 8. Installation of CO2 Air Line inside Cabinet: Remove rubber plug located at the exterior (top right hand corner) of the cabinet. (store this plug in a safe place, it will be required when converting your unit back to a basic refrigerator) Insert the open end of the air line into the cabinet throug ...
-
Danby DKC445BL - page 9
7 CHILL'N TAP ASSEMBL Y INSTRUCTIONS CON’T 1 6 . Installation of the Keg Coupler: IMPORT A N T N O T I C E ; Make sure the black pull handle of the keg coupler is in the "upward" (closed) position before installing on the beer keg. See Fig. 9 Insert the keg coupler into the locking neck of the beer keg and apply a 1/4 turn clockwis ...
-
Danby DKC445BL - page 10
8 HOW TO REPLACE AN EMPTY CO2 CYLINDER 1. Close the main cylinder valve (A) by turning in a clockwise direction. See Fig.13 2. Close the secondary shut-off valve (C) by turning to "horizontal" (east/west) position on lower stem pipe. See Fig.13 3. Remove the air line clamp and hose from the regulator . 4. Remove the regulator assembly (E) ...
-
Danby DKC445BL - page 11
9 CHANGING THE DIRECTION OF THE DOOR OPENING (SWING) If you find the direction of the door swing on your appliance inconvenient, you can change it to the opposite side. Simply follow the steps listed below . 1. Lay the unit on it's back. 2. Remove the adjustable leveling leg from the lower right hinge. 3. Remove two (2) screws from the lower d ...
-
Danby DKC445BL - page 12
10 HELPFUL HINTS TO ASSIST YOU IN SERVING THE PERFECT GLASS OF COLD BEER STORAGE AND HANDLING: • Draught Beer should be treated as a food product. In most instances draught beer is not pasteurized. It is very important that you store and handle it properly . • Draught Beer should be immediately stored in a refrigerated cabinet. • Draught Beer ...
-
Danby DKC445BL - page 13
11 KEG SIZES There are two(2) standard size beer kegs that can be used in your Chill 'N T ap Keg Cooler. 30 Liter Keg (1/4 Barrel) yields 3-1/2 cases (1056ozs) of beer. (Keg Weight 91lbs Full) 20 Liter Keg ( 1/6 Barrel) yields 2-1/2 cases (704ozs) of beer (Keg Weight 54lbs Full) Note: The keg stand is required only when using the 30 liter size ...
-
Danby DKC445BL - page 14
12 CONVERTING THE CHILL 'N TAP KEG COOLER T O A BASIC "ALL REFRIGERA TOR": The Chill 'N T ap Keg Cooler is designed to offer you quick and easy conversion from a beer dispensing unit to a basic compact "All Refrigerator" application. Simply follow the below steps; 1. Close the main valve on the CO2 cylinder . 2. Close ...
-
Danby DKC445BL - page 15
LIMITED PRODUCT WARRANTY This quality product is warranted to be free from manufacturer ’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer . This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distribu ...