Siemens RS-485の取扱説明書

14ページ 0.14 mb
ダウンロード

ページに移動 of 14

Summary
  • Siemens RS-485 - page 1

    CC1A7865.1en 31.10.2002 Sie mens Bu ildi ng Tech nolo gies HVAC Product s 7 865.1 Interface RS-485 RWF40... The RS-485 interface is used f or integrati ng RW F40… controllers into data networks via MOD bus protocol. Application examples: - Process v isualiz ation - Plant control - Reporting Master-slave principle Communication between a PC (maste ...

  • Siemens RS-485 - page 2

    2/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Transmission mode (RT U) The transmission mode used is the RTU (re mote terminal unit) mode. Data are trans- mitted in binary format (hexadecimal) with 8 bits. The LSB (least significant bit) is transmitted first. ASCII mode is not supported. The data format describes the s ...

  • Siemens RS-485 - page 3

    3/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Communication se quence Both the start and end of a data block are c haracterized by transmiss ion pauses. The maximum period of tim e that m ay elapse between 2 successi ve characters is 3 times the period of time required for the transmis sion of one character. The charac ...

  • Siemens RS-485 - page 4

    4/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Data query sequence The time sequence of a data query looks as follows: Master Sl ave Data qu er y Rep ly Data qu ery t 0 t 1 t 0 t 2 7865z12e/1102 t0 Identification of end = 3 characters (time is dependent on the Baud rate) t1 This time is dependent on internal handling. T ...

  • Siemens RS-485 - page 5

    5/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Structure of the data blocks All data blocks use the same structure: Slave address Function c ode Data field Checksum CRC16 1 byte 1 byte x byte 2 bytes Every data block contains 4 fields: Slave address Device address of a certain slave Function c ode Function selection (re ...

  • Siemens RS-485 - page 6

    6/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Checksum (CRC16) The che cksum ( CRC1 6) is used to det ect tra nsmissio n err ors. If the evaluation reveals an error , the relevant device will not respond. CRC = 0xFFF CRC = CRC XOR ByteOfMessage For (1 to 8) CRC = SHR (CRC) if (flag to the right = 1) then CRC = CRC XOR ...

  • Siemens RS-485 - page 7

    7/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Reading n words This function is used to read n words from a certain address. Slave address Function 0x03 or 0x04 Address of the first w ord Number of wor d s (max. 12) Checksum CRC16 1 byte 1 byte 2 bytes 2 bytes 2 bytes Slave address Function 0x03 or 0x04 Number of bytes ...

  • Siemens RS-485 - page 8

    8/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Writing n w ords Slave address Function 0x10 Address of first word Number of words Number of by t es (max. 2) Word value(s) Check- sum CRC16 1 byte 1 byte 2 by tes 2 bytes 1 byte x byte(s) 2 bytes Slave address Function 0x10 Address of first w ord Number of wor ds Checksum ...

  • Siemens RS-485 - page 9

    9/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Address tables Address Data typ e Access Parameter Value range Default valu e 0x0000 f loat R / O Actual value E1 0x0002 f loat R / O Actual value E2 0x0004 f loat R / O Actual value E3 0x0006 f loat R / W Current setpoint 0x0008 f loat R / W SP1 First setpoint SPL...SPH 0 ...

  • Siemens RS-485 - page 10

    10/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Address Data typ e Access Parameter Value range Default valu e 0x0300 word [13] R / O Device data 0x0300 char SW Version [11+1] Software version 0x0306 char VDNNr [13+1] VdN number Address Data typ e Access Parameter Value range Default valu e 0x0400 f loat R / O TEMP Actu ...

  • Siemens RS-485 - page 11

    11/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Address Data type Access Parameter 0x0200 word R / O Outputs and states B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 B8 Hysteresis limitation B0 Output 1 off (for remote operation) B1 Output 3 off B9 Management system off B2 Output 2 off (for remote operation) B3 ...

  • Siemens RS-485 - page 12

    12/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Description of operati ng modes Parameter «RemoteStatus» is used to switch between the operating modes «LOCAL», «REMOTE SETPOINT» and «FULLY REMOTE». The change is always accomplished via the MOD bus. In the event the master fails or communication is lost, the R W ...

  • Siemens RS-485 - page 13

    13/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 The previous functions of the RW F40... are maintained (apart from mem ory usage). The R W F40... can be parameterized and uploaded via the MOD bus, whereby the out- puts cannot be changed. After «Power-up», the R W F40... will normally assume oper- ating mode «LOCAL». ...

  • Siemens RS-485 - page 14

    14/14 Siemens Building Technologie s CC1A7865.1e n HVAC Produ cts 31.10.2002 Modulating controller: The management system predefines the va lue (degree of modulat ion) for the analog output via «RY». Setting the «RK2» and «RK3» by the management system has no impact. Both relays «K2» and «K3», are deenergized. Floating step controller: Th ...

メーカー Siemens カテゴリー Cell Phone

Siemens RS-485のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RS-485の取扱説明書
- Siemensの製品カード
- パンフレット
- またはSiemens RS-485の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Siemens RS-485の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Siemens RS-485の取り付け説明書、サービスマニュアル、簡易説明書、またはSiemens RS-485のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Siemens RS-485の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Siemens RS-485デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSiemens RS-485を使用するのを助ける技術的文書のことです。説明書は通常、全てのSiemens RS-485ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Siemensの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Siemens RS-485の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSiemens RS-485の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Siemens RS-485に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Siemens RS-485デバイスの基本機能を使うにあたってのヒント。 Siemens RS-485のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Siemens RS-485に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSiemens RS-485のメーカー/サービスへの連絡先に関する情報。

Siemens RS-485についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSiemens RS-485の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSiemens RS-485で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)