  • Turbo Air MSR-72G-3 - page 1

    T urbo air Speeds Up the P ace of Inno vation Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! <Solid Door> Refrigerator MSR-23NM MSR-49NM Freezer MSF-23NM MSF-49NM <Glass Door> Refrigerator MSR-23G-1 MSR-49G-2 MSR-72G-3 CA UTION! PLEASE KEE ...

  • Turbo Air MSR-72G-3 - page 2

    1. SPECIFICATION .......................................................................................... 2 2. SERIAL NUMBER ........................................................................................ 2 3. INSTALLATION ............................................................................................ 3 4. CLEANING ......... ...

  • Turbo Air MSR-72G-3 - page 3

    3 Turbo air 1. GOOD AIR CIRCULA TION - Be sure to avoid any partition and object which may stop the air flow. - Be sure that air space is allowed to flow the rear of the unit. Turbo air recommends that the rear of the unit would be no less than 5 inches from the wall. 2. PLA CE ON STR ONG GROUND - Be sure that the location be chosen has a strong en ...

  • Turbo Air MSR-72G-3 - page 4

    4 Turbo air CLEANING 1. CLEANING ST AINLESS STEEL INTERIOR AND EXTERIOR (select models) : Damage to stainless steel finish due to improper use of cleaning products or non- recommended products is NOT covered under this product's warranty. • DO NOT USE - Abrasive or harsh cleaners - Ammonia - Chlorine bleach - Concentrated detergents or solve ...

  • Turbo Air MSR-72G-3 - page 5

    5 Turbo air B ASIC OPERA TION MSR-23NM MSR-23G-1 MSR-49NM MSR-49G-2 MSR-72G-3 1. Plug in and turn on the power switch located on the bottom of the top grille right side. The Display panel will be lighted and make a beep sound. The compressor will begin to run. 2. The default temperature setting is No. “5”. 3. The compressor is automatically cyc ...

  • Turbo Air MSR-72G-3 - page 6

    6 Turbo air DISPLA Y P ANEL OF REFRIGERA T OR 9 TEMPERA TURE Q .C. 8 7 6 5 4 3 2 1 FA N DOOR QUICK COOLING TEMPERA TURE ˚F TEMP . SETTING QUICK COOLING F AN RUNNING DOOR OPENING QUICK COOLING BUTTON TEMP . CONTROL BUTTON (SEE T O P AGE 7) INNER TEMP . (SEE T O P AGE 8) (SEE T O P AGE 7) ...

  • Turbo Air MSR-72G-3 - page 7

    7 Turbo air 1. If you push the Q.C. (QUICK Cooling) button, the compressor will run continuously until D-Senser detect 14 ˚ F (-10 ˚ C) to bring down the temperature more quickly. (max.comp.run time = 120 min.) 2. If you push the Q.C. button again during QUICK Cooling mode, the compressor will return to the normal operation. 3. During the QUICK C ...

  • Turbo Air MSR-72G-3 - page 8

    8 Turbo air 1. It displays the inside temperature. 2. Display range is 14 ˚ F to 69 ˚ F (-10 ˚ C ~ +20 ˚ C). 3. When the inside temperature is lower than 14 ˚ F, the panel will display ‘ ’. and, higher than 69 ˚ F, the panel will display ‘ ’. 1. If the fan motor is running, fan running indicator will be turned on. 2. Evaporator fan mo ...

  • Turbo Air MSR-72G-3 - page 9

    9 Turbo air B ASIC OPERA TION 1. Plug in and turn on the power switch located on the bottom of the top grille right side. The Display panel will be lighted and make a beep sound. The compressor will begin to run. 2. The default temperature setting is No. “5”. 3. The compressor is automatically cycled by the electronic controller (PCB, F-Sensor) ...

  • Turbo Air MSR-72G-3 - page 10

    10 Turbo air DISPLA Y P ANEL OF FREEZER 9 TEMPERA TURE D.F . 8 7 6 5 4 3 2 1 FA N DOOR MANU AL DEFROST TEMPERA TURE ˚F TEMP . SETTING MANUAL DEFROST F AN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP . CONTROL BUTTON (SEE T O P AGE 1 1) INNER TEMP . (SEE T O P AGE 12) (SEE T O P AGE 1 1) ...

  • Turbo Air MSR-72G-3 - page 11

    11 Turbo air 1. If you push MANUAL DEFROST button for 5 seconds, the Defrost will start. 2. During the Manual Defrost mode, the Up/Down button for the temperature control can not make the compressor cycle ON or OFF. 3. If you want to change the Manual Defrost mode to the normal mode, push MANUAL DEFROST button for 5 seconds. 1. By pushing the up/do ...

  • Turbo Air MSR-72G-3 - page 12

    12 Turbo air 1. It displays inside temperature. 2. Display range is -50 ˚ F to 50 ˚ F (-45 ˚ C ~ +10 ˚ C). 3. When inside temperature is lower than -50 ˚ F, the panel will display ‘ ’. and, higher than +50 ˚ F, the panel will show ‘ ’. 1. If the fan motor is running, fan running indicator will be turned on. 2. Evaporator fan motor is ...

  • Turbo Air MSR-72G-3 - page 13

    13 Turbo air BEFORE REQUESTING SER VICE SYMPT OMS CA USES SOLUTIONS Freezer is melting f ood. The unit does not refrigerate at all. The unit does not refrigerate well. There is a loud noise. There are dew-dr ops on the unit exterior . There are dew-dr ops on the unit interior . The door does not c lose tightly . • The controller is set too high t ...

  • Turbo Air MSR-72G-3 - page 14

    14 Turbo air MANUF A CTURING COMP ANY Turbo air warrants to the original purchaser of every new-Turbo air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal use and service, for a period of one (1) year from the date of original installation or 15 months after shipment date from Tu ...

  • Turbo Air MSR-72G-3 - page 15

    15 Turbo air WHA T IS NO T CO VERED BY THIS W ARRANTY Turbo air’s obligation under warranty is limited to either repair or replacement of parts, subject to the additional limitation s below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty. 1. WARRANTY IS NOT TRANSFERABLE. ...

  • Turbo Air MSR-72G-3 - page 16

    Warranty Claims... All claims for parts or labor must be made directly thorough Turbo Air. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. In case of compressor replacement under warranty, either compressor or ...

メーカー Turbo Air カテゴリー Refrigerator

Turbo Air MSR-72G-3のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MSR-72G-3の取扱説明書
- Turbo Airの製品カード
- パンフレット
- またはTurbo Air MSR-72G-3の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Turbo Air MSR-72G-3の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Turbo Air MSR-72G-3の取り付け説明書、サービスマニュアル、簡易説明書、またはTurbo Air MSR-72G-3のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Turbo Air MSR-72G-3の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Turbo Air MSR-72G-3デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがTurbo Air MSR-72G-3を使用するのを助ける技術的文書のことです。説明書は通常、全てのTurbo Air MSR-72G-3ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Turbo Airの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Turbo Air MSR-72G-3の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははTurbo Air MSR-72G-3の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Turbo Air MSR-72G-3に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Turbo Air MSR-72G-3デバイスの基本機能を使うにあたってのヒント。 Turbo Air MSR-72G-3のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Turbo Air MSR-72G-3に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるTurbo Air MSR-72G-3のメーカー/サービスへの連絡先に関する情報。

Turbo Air MSR-72G-3についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもTurbo Air MSR-72G-3の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがTurbo Air MSR-72G-3で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)