Manual Goodman Mfg GSX130421B

44 pages 0.7 mb
Download

Go to site of 44

Summary
  • Goodman Mfg GSX130421B - page 1

    SS-GSX13 www .goodmanmfg.com 2/14 Supersedes 11/13 GSX1 3 S plit S yStem A ir C onditioner 13 Seer / 1½ t o 5 t onS C oolinG C Ap ACity : 1 8,000 - 60,000 BtU/ h Standard Featur es • R-410Achlorine-freer efrigerant • Energ y-efcientcompressor • Factor y-installedlterdrier • Coppertube/aluminumnc ...

  • Goodman Mfg GSX130421B - page 2

    P roduct S Pecifica tionS 2 www .goodmanmfg.com SS-GSX13 n omenClA tUre Brand Engineering * G Goodman ® Brand or Minor Revision Amana ® Distinctions ® Brand Engineering * Major Revision Product Category Electrical S Split System 1 208-230 V , 1 Phase, 60 Hz 2 220/240 V , 1 Phase, 50 Hz Unit T ype 3 208-230 V , 3 Phase, 60 Hz C Condenser R-22 4 4 ...

  • Goodman Mfg GSX130421B - page 3

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 3 S peCifiCA tionS GSX13 0181E* GSX13 0241D* GSX13 0301B* GSX13 0361C* GSX13 0361E* GSX13 0421B* GSX13 0481B* GSX13 0601B* GSX13 0611A* Cap acities Nominal Cooling (BTU/h) 18,000 24,000 30,000 36,000 36,000 42,000 48,000 60,000 60,000 SEER / EER 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 1 ...

  • Goodman Mfg GSX130421B - page 4

    P roduct S Pecifica tionS 4 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 301 81e* / CApf1 824B6dB Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 525 MBh 15.6 16.2 17.7 - 15.3 15.8 17.3 ...

  • Goodman Mfg GSX130421B - page 5

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 5 e Xp Anded C oolinG d A tA — GSX1 301 81e* / CApf1 824B6dB ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 525 MBh 16.2 16.5 17.7 18.9 1 ...

  • Goodman Mfg GSX130421B - page 6

    P roduct S Pecifica tionS 6 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 302 4 1d* / CA*f1 82 4*6d* Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 700 MBh 20.2 20.9 22.9 - 19.7 20.4 22 ...

  • Goodman Mfg GSX130421B - page 7

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 7 e Xp Anded C oolinG d A tA — GSX1 302 4 1d* / CA*f1 82 4*6d* ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 700 MBh 20.9 21.4 22.8 24.4 ...

  • Goodman Mfg GSX130421B - page 8

    P roduct S Pecifica tionS 8 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 30 301B* / CA *f30 30*6d* Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 945 MBh 26.2 27.2 29.8 - 25.6 26.6 29. ...

  • Goodman Mfg GSX130421B - page 9

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 9 e Xp Anded C oolinG d A tA — GSX1 30 301B* / CA *f30 30*6d* ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 945 MBh 27.2 27.8 29.6 31.7 ...

  • Goodman Mfg GSX130421B - page 10

    P roduct S Pecifica tionS 10 www .goodmanmfg.com SS-GSX13 Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1350 MBh 32.8 34.0 37.2 - 32.0 33.2 36.4 - 31.3 32.4 35.5 - 30.5 31.6 34.6 - 29.0 30.0 32.9 - 26.8 ...

  • Goodman Mfg GSX130421B - page 11

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 11 Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1350 MBh 33.93 34.67 37.04 39.59 33.14 33.86 36.18 38.67 32.35 33.06 35.32 37.75 31.56 32.25 34.46 ...

  • Goodman Mfg GSX130421B - page 12

    P roduct S Pecifica tionS 12 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 30 36 1e* / CA *f3 6 3 6*6d* Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1350 MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 ...

  • Goodman Mfg GSX130421B - page 13

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 13 e Xp Anded C oolinG d A tA — GSX1 30 36 1e* / CA *f3 6 3 6*6d* ( Cont .)    65ºF 75ºF 85ºF 95ºF 105ºF 115ºF  ? ...

  • Goodman Mfg GSX130421B - page 14

    P roduct S Pecifica tionS 14 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 30421B* / CA *f3 642*6B* Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1225 MBh 36.0 37.3 40.9 - 35.2 36.4 39 ...

  • Goodman Mfg GSX130421B - page 15

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 15 e Xp Anded C oolinG d A tA — GSX1 30421B* / CA *f3 642*6B* ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1225 MBh 37.3 38.1 40.7 43.5 ...

  • Goodman Mfg GSX130421B - page 16

    P roduct S Pecifica tionS 16 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 30481B* / CA *f4860*6B* Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1400 MBh 40.4 41.9 45.9 - 39.5 40.9 44. ...

  • Goodman Mfg GSX130421B - page 17

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 17 e Xp Anded C oolinG d A tA — GSX1 30481B* / CA *f4860*6B* ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1400 MBh 41.8 42.7 45.6 48.8 ...

  • Goodman Mfg GSX130421B - page 18

    P roduct S Pecifica tionS 18 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 30601B* / CA *f496 1*6A * Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1500 MBh 50.1 51.9 56.8 - 48.9 50.7 5 ...

  • Goodman Mfg GSX130421B - page 19

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 19 e Xp Anded C oolinG d A tA — GSX1 30601B* / CA *f496 1*6A* ( Cont .) Outdoor Ambient Temper a ture 65ºF 75ºF 85ºF 95ºF 105ºF 115ºF Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1500 MBh 51.8 52.9 56.6 60.5 ...

  • Goodman Mfg GSX130421B - page 20

    P roduct S Pecifica tionS 20 www .goodmanmfg.com SS-GSX13 e Xp Anded C oolinG d A tA — GSX1 306 1 1*/CA *f496 1*6d*+eep Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1500 MBh 53.8 55.7 61.0 - 52.5 54.4 59.6 - 51.3 53.1 ...

  • Goodman Mfg GSX130421B - page 21

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 21 e Xp Anded C oolinG d A tA — GSX1 306 1 1*/CA *f496 1*6d*+eep ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1500 MBh 55.6 56.9 60.7 64.9 54.3 55.5 59.3 ...

  • Goodman Mfg GSX130421B - page 22

    P roduct S Pecifica tionS 22 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0181E* ACNF18XX16D* 16,800 12,800 13.00 10.80 600 5039733 ACNF24XX16D* 17,000 13,000 13.00 10.80 600 5039734 ARPT18B14A* 17,400 13,30 ...

  • Goodman Mfg GSX130421B - page 23

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 23 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0181E* CAPT3131*4A* A*EH800603B*A* 18,000 13,700 14.00 11.50 650 6944836 CAPT3131*4A* AMEH960403B XA* 18,000 13,700 14.00 1 ...

  • Goodman Mfg GSX130421B - page 24

    P roduct S Pecifica tionS 24 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0241D* CA*F1824*6D* A*VC950453BXB* 23,000 16,900 14.00 11.60 800 6497537 CA*F1824*6D* G*VC950453BXB* 23,000 16,900 14.00 11 ...

  • Goodman Mfg GSX130421B - page 25

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 25 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0301B* ACNF30XX16D* 27,600 20,800 13.00 11.00 890 4689680 ARPT30B14A* 27,000 20,400 13.00 11.00 900 5383473 ARUF30B14A* 27, ...

  • Goodman Mfg GSX130421B - page 26

    P roduct S Pecifica tionS 26 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0301B* CA*F3131*6D*+MBVC1200**-1A* 28,400 21,400 14.00 11.50 950 4385559 CA*F3636*6D*+EEP 28,400 21,400 13.00 11.00 1,000 5 ...

  • Goodman Mfg GSX130421B - page 27

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 27 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0301B* CAPT3743*4A*+MBVC1600**-1A* 28,200 21,200 14.00 11.50 1,000 5611307 CHPF2430B6C* GME950403B XA* 28,400 21,400 14.00 ...

  • Goodman Mfg GSX130421B - page 28

    P roduct S Pecifica tionS 28 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0361E* CA*F3642*6D* G*VC950905CXB* 34,000 26,400 14.00 11.50 1,165 5696692 CA*F3642*6D* A*VC950714CXB* 34,000 26,400 14.00 ...

  • Goodman Mfg GSX130421B - page 29

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 29 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0361E* CAPT3743*4A* A*VM961005DXB* 34,000 26,400 13.50 11.50 1,170 6494238 CAPT3743*4A* GME950805CXA* 33,400 26,000 13.50 1 ...

  • Goodman Mfg GSX130421B - page 30

    P roduct S Pecifica tionS 30 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0421B* CA*F3642*6D*+EEP 40,000 30,600 13.00 11.00 1,400 4946292 CA*F3642*6D*+EEP+TXV 40,000 30,600 13.00 11.00 1,400 556191 ...

  • Goodman Mfg GSX130421B - page 31

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 31 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0421B* CHPF3642D6C* G*VC950905CXB* 40,000 30,600 13.50 11.30 1,400 5621024 CHPF3642D6C*+EEP 40,000 30,600 13.00 11.00 1,400 ...

  • Goodman Mfg GSX130421B - page 32

    P roduct S Pecifica tionS 32 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0481B* CA*F4860*6D*+TXV A*VM960604CXB* 46,000 35,200 14.00 11.30 1,550 5621064 CA*F4860*6D*+TXV A*VM960805CXB* 46,000 35,20 ...

  • Goodman Mfg GSX130421B - page 33

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 33 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0481B* CHPF4860D6D*+TXV A*EH801005C*A* 46,000 35,200 13.50 11.30 1,570 6944925 CHPF4860D6D*+TXV AMEH960805CXA* 45,500 34,80 ...

  • Goodman Mfg GSX130421B - page 34

    P roduct S Pecifica tionS 34 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0601B* CAPT4961*4A* A*VC950915D XB* 55,000 39,000 13.00 11.00 1,660 5621088 CAPT4961*4A* G*VM961005DXB* 54,500 38,500 13.00 ...

  • Goodman Mfg GSX130421B - page 35

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 35 Ahri r A tinGS ( Cont .) Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0611A* ARPT48D14A* 54,500 37,400 13.00 11.00 1,500 5586528 ARPT60D14A* 55,000 37,600 13.00 11.00 1,500 5586693 ARUF48D14A* 54,500 37,400 13.00 11. ...

  • Goodman Mfg GSX130421B - page 36

    P roduct S Pecifica tionS 36 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0611A* CA*F4961*6D*+TXV G*VC80805C*B* 56,500 38,500 14.00 11.50 1,520 5586612 CA*F4961*6D*+TXV G*VC81005C*B* 56,500 38,500 ...

  • Goodman Mfg GSX130421B - page 37

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 37 Ahri r A tinGS ( Cont .) See Notes on P age 38. Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0611A* CAPT4961*4A* G*VC950905CXB* 56,500 38,500 13.50 11.00 1,460 5621112 CAPT4961*4A* A*VC950905D XB* 56,500 38,500 14.00 ...

  • Goodman Mfg GSX130421B - page 38

    P roduct S Pecifica tionS 38 www .goodmanmfg.com SS-GSX13 Ahri r A tinGS ( Cont .) Outdoor Unit Indoor Units Cooling Ra tings CFM AHRI # Coils/ Air Handlers Furnace s T ot al¹ Sens.¹ SEER² EER³ GSX13 0611A* CSCF4860N6D*+TXV GME951005DXA* 55,000 37,600 13.50 11.00 1,500 5589957 CSCF4860N6D*+TXV A*VC950905CXB* 55,000 37,600 13.50 11.00 1,475 5621 ...

  • Goodman Mfg GSX130421B - page 39

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 39 d imenSionS H W D Model Dimensions W” D” H” GSX130181E* 23 23 25¾ GSX130241D* 23 23 25¾ GSX130301B* 26 26 27½ GSX130361C* 29 29 28¾ GSX130361E* 26 26 27½ GSX130421B* 29 29 36¼ GSX130481B* 29 29 36¼ GSX130601B* 29 29 40 GSX130611A* 35½ 35½ 38¼ ...

  • Goodman Mfg GSX130421B - page 40

    P roduct S Pecifica tionS 40 www .goodmanmfg.com SS-GSX13 W irinG d iAGrAm — GSX1 3 01 81e USE N.E.C. CLASS 2 WIRE COMP ALTERNA TE DOUBLE POLE CONTACTO R ONL Y IO T1 M A I N R A U X 5 S SR SA 2 1 RCCF SC T2 C L1 L2 (IF USED) C H C F M A I N A U X C C 0140R00258-B BL Y C LVJB COL OR C ODE BK ------- -------- BLACK BL --------- ------ BLUE BL/PK -- ...

  • Goodman Mfg GSX130421B - page 41

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 41 W irinG d iAGrAm — GSX1 3 0(3 0-60)1B/C/e*     ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W ARNING High V oltage:  ? ...

  • Goodman Mfg GSX130421B - page 42

    P roduct S Pecifica tionS 42 www .goodmanmfg.com SS-GSX13     ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W ARNING High V oltage:      ? ...

  • Goodman Mfg GSX130421B - page 43

    P roduct S Pecifica tionS SS-GSX13 www .goodmanmfg.com 43 W irinG d iAGrAm — GSX1 3 06 1 1*     ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W ARNING High V oltage:   ? ...

  • Goodman Mfg GSX130421B - page 44

    P roduct S Pecifica tionS 44 www .goodmanmfg.com SS-GSX13 Goodman Manufacturing Company , L.P ., reserves the right to discontinue, or change at any time, specica tions or designs without notice or without incurring obligations. © 2014 • Goodman Manufacturing Company , L.P . • Houston, T exas • Printed in the USA. A CCeSSorieS Model De sc ...

Manufacturer Goodman Mfg Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Mfg GSX130421B can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GSX130421B manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GSX130421B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GSX130421B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GSX130421B, service manual, brief instructions and user manuals Goodman Mfg GSX130421B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GSX130421B.

A complete manual for the device Goodman Mfg GSX130421B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GSX130421B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GSX130421B.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GSX130421B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GSX130421B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GSX130421B, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GSX130421B - which should help us in our first steps of using Goodman Mfg GSX130421B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GSX130421B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GSX130421B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GSX130421B?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GSX130421B, ask a question using the form below. If a user had a similar problem with Goodman Mfg GSX130421B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)