    Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322008r3 August 2009 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. GPC15 SEER Multi-Po ...

  • Goodman Mfg GPC15 SEER - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodman Mfg GPC15 SEER - page 3

    PRODUCT IDENTIFICA TION 3 GPC1524M41A* GPC1530M41A* GPC1536M41A* GPC1542M41A* GPC1548M41A* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“EPA”) has issued v ...

  • Goodman Mfg GPC15 SEER - page 4

    4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions and are available in 2, 2-1/2, 3, 3-1/2 and 4 ton sizes. They are designed for 208/230 volt single phase applications. The connecting ductwork (Supply and Return) can be con- nected for either horizontal ...

  • Goodman Mfg GPC15 SEER - page 5

    PRODUCT DESIGN 5 Roo f Cur b Rooftop Installation - Multi-positional (M) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- ...

  • Goodman Mfg GPC15 SEER - page 6

    6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du ...

  • Goodman Mfg GPC15 SEER - page 7

    PRODUCT DIMENSIONS 7 BLOWE R ACCE SS P ANEL ? ? 2 3 4 51 47 SUP PL Y 1 3/8 A RET URN POWE R WI R E ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTROL WI R E ENT RANCE CONDENS A TE DRAI N CONNECTIO N 3 /4” NPT FEMALE 18 7/8 SUCTIO N/LIQUID PRE SSU RE PORT 3 8 MEDIUM CHASSIS GPC1524M41* GPC1530M41* GPC1536M41* LARGE CHASSIS GPC1542M41* GPC1548M41* G ...

  • Goodman Mfg GPC15 SEER - page 8

    P ACKAGE COOLING SPECIFICA TIONS 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg GPC15 SEER - page 9

    ACCESSORIES 9 P a rt Nu m b e r D es c ri p t i o n O T 18- 60 A O ut door Ther mosta t Kit w/Lo c k out S tat O T /EHR 18- 60 Eme r genc y Heat R el ay Ki t HKR Electric Heat Ki t P G C101/10 2/103 Roof Cur b PEHH101/ 102 Hor iz on tal Ec onomi z er For Heat Pum p , Smal l and Me di um C hass is PEHH103 Hor iz on tal Ec onomi z er F or H eat Pum p ...

  • Goodman Mfg GPC15 SEER - page 10

    10 BLOWER PERFORMANCE DA T A Dry Coil Data GPC15[24-48]M41A* NOTES: • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. • Data shown does not include filter pressure drop, approx. 0.08” H 2 O. • ALL MODELS SHOUL ...

  • Goodman Mfg GPC15 SEER - page 11

    BLOWER PERFORMANCE DA T A 11 30 40 50 6 0 70 80 90 110 1 20 100 13 0 14 0 150 100 90 80 70 60 50 40 30 20 10 OUT PU T B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 CF M 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.08 x RI SE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodman Mfg GPC15 SEER - page 12

    12 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PA N DE D P ER F O R M A N C E D ATA C OOL ING OP ER ATI ON De sign S ubco oli n g, 7 °F @ the li quid a cc e s s fitt i ng conn e c t i o n AHR I 95 t e st c onditions . D e s i gn S uperhe at 5 °F @ t he comp re ss or s u ct i o n acc ess f it ting co n n ec t i o n . O ut d o ...

  • Goodman Mfg GPC15 SEER - page 13

    13 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he comp re ss or s u ct i on acc ess f it t in g co n n ec ti o n . O u t d o ...

  • Goodman Mfg GPC15 SEER - page 14

    14 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 EX PA N DE D P ER FO R MANC E D ATA C OOL I NG OP ER ATI ON De sign S ubco oli n g, 7 °F @ the l i qui d a c c e ss fitt i ng conn e c ti o n AHR I 95 t e st c ondi tions . D e s i gn S uperhe at 5 °F @ t he comp re ss or s ucti o n acc ess f it t in g co nn ec t i o n . O u t d o o ...

  • Goodman Mfg GPC15 SEER - page 15

    15 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 E XP A ND ED PE RF O R M A N CE DA T A C OOL IN G OP ERAT ION De s i gn S ubc ooli n g, 7 °F @ the l i quid a c cess fi tt i ng c onne c tio n AHR I 9 5 t e s t c ondi ti ons . D e sign S uperhe a t 5 ° F @ t he comp re s s or s uct ion ac c es s f i t ti ng c onne c tion. O u t d o ...

  • Goodman Mfg GPC15 SEER - page 16

    16 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss f i t t ing co n nec t i o n A HR I 95 t est co n d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com pre ssor suct i o n acc ess f it ting co n n ec t i o ...

  • Goodman Mfg GPC15 SEER - page 17

    17 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he comp re ss or s u ct i on acc ess f it t in g co n n ec ti o n . O u t d o ...

  • Goodman Mfg GPC15 SEER - page 18

    18 COOLING PERFORMANCE DA T A GPC1542M41* MOD E L : G PC1542M41 E XP A ND ED PE RF ORM A N CE DA T A C OOL ING OP ER ATION Desi gn Su bco o l i n g , 7 ° F @ t he l iq ui d a cce ss f i tt ing co n n ec ti o n A H R I 95 t est co n di ti o ns. D e si g n S u p er heat 5 ° F @ t h e com pre ssor s uc tion a c c es s f i t ti ng c onne cti on. Ou t ...

  • Goodman Mfg GPC15 SEER - page 19

    19 COOLING PERFORMANCE DA T A GPC1542M41* M O DEL : GP C1 5 4 2 M 4 1 E XP A ND ED PE RF O RM A N CE DA T A C O OLI NG OP ER AT ION Desi gn Su bco o l i n g , 7 ° F @ t h e l iq ui d a cce ss f i t t in g con n ec ti o n A HR I 95 t est co n di t i o ns. D e si g n S u p er heat 5 ° F @ t h e co m p r e sso r s uc tion a c c es s f i t ti ng co n ...

  • Goodman Mfg GPC15 SEER - page 20

    20 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G PC 1548M41 EX PAN DE D P ER F OR MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss f i t t ing co n nec t i o n A HR I 95 t est co n d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com pre ssor suct i o n acc ess f it ting co n n ec t i o ...

  • Goodman Mfg GPC15 SEER - page 21

    21 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G P C 1548M41 E XP A ND E D PE RF O RM A N CE DA TA C OO LIN G OPE R A TIO N De sign S ubc ool i n g, 7 °F @ the l i qui d a c c e s s fi tt i ng c onne c ti o n AHR I 9 5 t e st c onditi ons . D e s i gn S upe r he a t 5 ° F @ t he c omp re s s or s uc ti on a cc es s f it ti ng conne c tion. O ...

  • Goodman Mfg GPC15 SEER - page 22

    22 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...

  • Goodman Mfg GPC15 SEER - page 23

    WIRING DIAGRAMS 23 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BK BK BK BK BK BK BK ...

  • Goodman Mfg GPC15 SEER - page 24

    24 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. GPC15[24-48]M41* 3 C ...

  • Goodman Mfg GPC15 SEER - page 25

    WIRING DIAGRAMS 25 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC15[24-48]M41* 2 3 ...

Manufacturer Goodman Mfg Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Mfg GPC15 SEER can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GPC15 SEER manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GPC15 SEER
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GPC15 SEER.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GPC15 SEER, service manual, brief instructions and user manuals Goodman Mfg GPC15 SEER. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GPC15 SEER.

A complete manual for the device Goodman Mfg GPC15 SEER, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GPC15 SEER by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GPC15 SEER.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GPC15 SEER - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GPC15 SEER, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GPC15 SEER, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GPC15 SEER - which should help us in our first steps of using Goodman Mfg GPC15 SEER
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GPC15 SEER
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GPC15 SEER in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GPC15 SEER?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GPC15 SEER, ask a question using the form below. If a user had a similar problem with Goodman Mfg GPC15 SEER it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)