    Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322008r3 August 2009 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. GPC15 SEER Multi-Po ...

  • Goodman Mfg GPC15 SEER - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodman Mfg GPC15 SEER - page 3

    PRODUCT IDENTIFICA TION 3 GPC1524M41A* GPC1530M41A* GPC1536M41A* GPC1542M41A* GPC1548M41A* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“EPA”) has issued v ...

  • Goodman Mfg GPC15 SEER - page 4

    4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions and are available in 2, 2-1/2, 3, 3-1/2 and 4 ton sizes. They are designed for 208/230 volt single phase applications. The connecting ductwork (Supply and Return) can be con- nected for either horizontal ...

  • Goodman Mfg GPC15 SEER - page 5

    PRODUCT DESIGN 5 Roo f Cur b Rooftop Installation - Multi-positional (M) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- ...

  • Goodman Mfg GPC15 SEER - page 6

    6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du ...

  • Goodman Mfg GPC15 SEER - page 7

    PRODUCT DIMENSIONS 7 BLOWE R ACCE SS P ANEL ? ? 2 3 4 51 47 SUP PL Y 1 3/8 A RET URN POWE R WI R E ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTROL WI R E ENT RANCE CONDENS A TE DRAI N CONNECTIO N 3 /4” NPT FEMALE 18 7/8 SUCTIO N/LIQUID PRE SSU RE PORT 3 8 MEDIUM CHASSIS GPC1524M41* GPC1530M41* GPC1536M41* LARGE CHASSIS GPC1542M41* GPC1548M41* G ...

  • Goodman Mfg GPC15 SEER - page 8

    P ACKAGE COOLING SPECIFICA TIONS 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg GPC15 SEER - page 9

    ACCESSORIES 9 P a rt Nu m b e r D es c ri p t i o n O T 18- 60 A O ut door Ther mosta t Kit w/Lo c k out S tat O T /EHR 18- 60 Eme r genc y Heat R el ay Ki t HKR Electric Heat Ki t P G C101/10 2/103 Roof Cur b PEHH101/ 102 Hor iz on tal Ec onomi z er For Heat Pum p , Smal l and Me di um C hass is PEHH103 Hor iz on tal Ec onomi z er F or H eat Pum p ...

  • Goodman Mfg GPC15 SEER - page 10

    10 BLOWER PERFORMANCE DA T A Dry Coil Data GPC15[24-48]M41A* NOTES: • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. • Data shown does not include filter pressure drop, approx. 0.08” H 2 O. • ALL MODELS SHOUL ...

  • Goodman Mfg GPC15 SEER - page 11

    BLOWER PERFORMANCE DA T A 11 30 40 50 6 0 70 80 90 110 1 20 100 13 0 14 0 150 100 90 80 70 60 50 40 30 20 10 OUT PU T B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 CF M 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.08 x RI SE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodman Mfg GPC15 SEER - page 12

    12 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PA N DE D P ER F O R M A N C E D ATA C OOL ING OP ER ATI ON De sign S ubco oli n g, 7 °F @ the li quid a cc e s s fitt i ng conn e c t i o n AHR I 95 t e st c onditions . D e s i gn S uperhe at 5 °F @ t he comp re ss or s u ct i o n acc ess f it ting co n n ec t i o n . O ut d o ...

  • Goodman Mfg GPC15 SEER - page 13

    13 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he comp re ss or s u ct i on acc ess f it t in g co n n ec ti o n . O u t d o ...

  • Goodman Mfg GPC15 SEER - page 14

    14 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 EX PA N DE D P ER FO R MANC E D ATA C OOL I NG OP ER ATI ON De sign S ubco oli n g, 7 °F @ the l i qui d a c c e ss fitt i ng conn e c ti o n AHR I 95 t e st c ondi tions . D e s i gn S uperhe at 5 °F @ t he comp re ss or s ucti o n acc ess f it t in g co nn ec t i o n . O u t d o o ...

  • Goodman Mfg GPC15 SEER - page 15

    15 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 E XP A ND ED PE RF O R M A N CE DA T A C OOL IN G OP ERAT ION De s i gn S ubc ooli n g, 7 °F @ the l i quid a c cess fi tt i ng c onne c tio n AHR I 9 5 t e s t c ondi ti ons . D e sign S uperhe a t 5 ° F @ t he comp re s s or s uct ion ac c es s f i t ti ng c onne c tion. O u t d o ...

  • Goodman Mfg GPC15 SEER - page 16

    16 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss f i t t ing co n nec t i o n A HR I 95 t est co n d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com pre ssor suct i o n acc ess f it ting co n n ec t i o ...

  • Goodman Mfg GPC15 SEER - page 17

    17 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he comp re ss or s u ct i on acc ess f it t in g co n n ec ti o n . O u t d o ...

  • Goodman Mfg GPC15 SEER - page 18

    18 COOLING PERFORMANCE DA T A GPC1542M41* MOD E L : G PC1542M41 E XP A ND ED PE RF ORM A N CE DA T A C OOL ING OP ER ATION Desi gn Su bco o l i n g , 7 ° F @ t he l iq ui d a cce ss f i tt ing co n n ec ti o n A H R I 95 t est co n di ti o ns. D e si g n S u p er heat 5 ° F @ t h e com pre ssor s uc tion a c c es s f i t ti ng c onne cti on. Ou t ...

  • Goodman Mfg GPC15 SEER - page 19

    19 COOLING PERFORMANCE DA T A GPC1542M41* M O DEL : GP C1 5 4 2 M 4 1 E XP A ND ED PE RF O RM A N CE DA T A C O OLI NG OP ER AT ION Desi gn Su bco o l i n g , 7 ° F @ t h e l iq ui d a cce ss f i t t in g con n ec ti o n A HR I 95 t est co n di t i o ns. D e si g n S u p er heat 5 ° F @ t h e co m p r e sso r s uc tion a c c es s f i t ti ng co n ...

  • Goodman Mfg GPC15 SEER - page 20

    20 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G PC 1548M41 EX PAN DE D P ER F OR MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss f i t t ing co n nec t i o n A HR I 95 t est co n d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com pre ssor suct i o n acc ess f it ting co n n ec t i o ...

  • Goodman Mfg GPC15 SEER - page 21

    21 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G P C 1548M41 E XP A ND E D PE RF O RM A N CE DA TA C OO LIN G OPE R A TIO N De sign S ubc ool i n g, 7 °F @ the l i qui d a c c e s s fi tt i ng c onne c ti o n AHR I 9 5 t e st c onditi ons . D e s i gn S upe r he a t 5 ° F @ t he c omp re s s or s uc ti on a cc es s f it ti ng conne c tion. O ...

  • Goodman Mfg GPC15 SEER - page 22

    22 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...

  • Goodman Mfg GPC15 SEER - page 23

    WIRING DIAGRAMS 23 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BK BK BK BK BK BK BK ...

  • Goodman Mfg GPC15 SEER - page 24

    24 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. GPC15[24-48]M41* 3 C ...

  • Goodman Mfg GPC15 SEER - page 25

    WIRING DIAGRAMS 25 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC15[24-48]M41* 2 3 ...

Fabbricante Goodman Mfg Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoGoodman Mfg GPC15 SEER possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Goodman Mfg
- manuali per l’uso GPC15 SEER
- schede prodotto Goodman Mfg
- opuscoli
- o etichette energetiche Goodman Mfg GPC15 SEER
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Goodman Mfg GPC15 SEER.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Goodman Mfg GPC15 SEER, manuali di manutenzione, brevi manuali o manuali utente Goodman Mfg GPC15 SEER. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Goodman Mfg GPC15 SEER.

Manuale completo del dispositivo Goodman Mfg GPC15 SEER, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Goodman Mfg GPC15 SEER dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Goodman Mfg GPC15 SEER.

Il manuale per l’uso completo Goodman Mfg, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Goodman Mfg GPC15 SEER - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Goodman Mfg GPC15 SEER, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Goodman Mfg GPC15 SEER che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Goodman Mfg GPC15 SEER - che ci dovrebbe aiutare nei primi passi durante l'uso Goodman Mfg GPC15 SEER
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Goodman Mfg GPC15 SEER
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Goodman Mfg GPC15 SEER in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Goodman Mfg GPC15 SEER?

Utilizza il modulo sottostante

Se non hai risolto il problema con Goodman Mfg GPC15 SEER con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Goodman Mfg GPC15 SEER è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)