  • Goodman Mfg GPC15 SEER - page 1

    Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322008r3 August 2009 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. GPC15 SEER Multi-Po ...

  • Goodman Mfg GPC15 SEER - page 2

    PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...

  • Goodman Mfg GPC15 SEER - page 3

    PRODUCT IDENTIFICA TION 3 GPC1524M41A* GPC1530M41A* GPC1536M41A* GPC1542M41A* GPC1548M41A* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. The United States Environmental Protection Agency (“EPA”) has issued v ...

  • Goodman Mfg GPC15 SEER - page 4

    4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions and are available in 2, 2-1/2, 3, 3-1/2 and 4 ton sizes. They are designed for 208/230 volt single phase applications. The connecting ductwork (Supply and Return) can be con- nected for either horizontal ...

  • Goodman Mfg GPC15 SEER - page 5

    PRODUCT DESIGN 5 Roo f Cur b Rooftop Installation - Multi-positional (M) NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- ...

  • Goodman Mfg GPC15 SEER - page 6

    6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du ...

  • Goodman Mfg GPC15 SEER - page 7

    PRODUCT DIMENSIONS 7 BLOWE R ACCE SS P ANEL ? ? 2 3 4 51 47 SUP PL Y 1 3/8 A RET URN POWE R WI R E ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTROL WI R E ENT RANCE CONDENS A TE DRAI N CONNECTIO N 3 /4” NPT FEMALE 18 7/8 SUCTIO N/LIQUID PRE SSU RE PORT 3 8 MEDIUM CHASSIS GPC1524M41* GPC1530M41* GPC1536M41* LARGE CHASSIS GPC1542M41* GPC1548M41* G ...

  • Goodman Mfg GPC15 SEER - page 8

    P ACKAGE COOLING SPECIFICA TIONS 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during ...

  • Goodman Mfg GPC15 SEER - page 9

    ACCESSORIES 9 P a rt Nu m b e r D es c ri p t i o n O T 18- 60 A O ut door Ther mosta t Kit w/Lo c k out S tat O T /EHR 18- 60 Eme r genc y Heat R el ay Ki t HKR Electric Heat Ki t P G C101/10 2/103 Roof Cur b PEHH101/ 102 Hor iz on tal Ec onomi z er For Heat Pum p , Smal l and Me di um C hass is PEHH103 Hor iz on tal Ec onomi z er F or H eat Pum p ...

  • Goodman Mfg GPC15 SEER - page 10

    10 BLOWER PERFORMANCE DA T A Dry Coil Data GPC15[24-48]M41A* NOTES: • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. • Data shown does not include filter pressure drop, approx. 0.08” H 2 O. • ALL MODELS SHOUL ...

  • Goodman Mfg GPC15 SEER - page 11

    BLOWER PERFORMANCE DA T A 11 30 40 50 6 0 70 80 90 110 1 20 100 13 0 14 0 150 100 90 80 70 60 50 40 30 20 10 OUT PU T B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 CF M 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.08 x RI SE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...

  • Goodman Mfg GPC15 SEER - page 12

    12 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PA N DE D P ER F O R M A N C E D ATA C OOL ING OP ER ATI ON De sign S ubco oli n g, 7 °F @ the li quid a cc e s s fitt i ng conn e c t i o n AHR I 95 t e st c onditions . D e s i gn S uperhe at 5 °F @ t he comp re ss or s u ct i o n acc ess f it ting co n n ec t i o n . O ut d o ...

  • Goodman Mfg GPC15 SEER - page 13

    13 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he comp re ss or s u ct i on acc ess f it t in g co n n ec ti o n . O u t d o ...

  • Goodman Mfg GPC15 SEER - page 14

    14 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 EX PA N DE D P ER FO R MANC E D ATA C OOL I NG OP ER ATI ON De sign S ubco oli n g, 7 °F @ the l i qui d a c c e ss fitt i ng conn e c ti o n AHR I 95 t e st c ondi tions . D e s i gn S uperhe at 5 °F @ t he comp re ss or s ucti o n acc ess f it t in g co nn ec t i o n . O u t d o o ...

  • Goodman Mfg GPC15 SEER - page 15

    15 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 E XP A ND ED PE RF O R M A N CE DA T A C OOL IN G OP ERAT ION De s i gn S ubc ooli n g, 7 °F @ the l i quid a c cess fi tt i ng c onne c tio n AHR I 9 5 t e s t c ondi ti ons . D e sign S uperhe a t 5 ° F @ t he comp re s s or s uct ion ac c es s f i t ti ng c onne c tion. O u t d o ...

  • Goodman Mfg GPC15 SEER - page 16

    16 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss f i t t ing co n nec t i o n A HR I 95 t est co n d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com pre ssor suct i o n acc ess f it ting co n n ec t i o ...

  • Goodman Mfg GPC15 SEER - page 17

    17 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he comp re ss or s u ct i on acc ess f it t in g co n n ec ti o n . O u t d o ...

  • Goodman Mfg GPC15 SEER - page 18

    18 COOLING PERFORMANCE DA T A GPC1542M41* MOD E L : G PC1542M41 E XP A ND ED PE RF ORM A N CE DA T A C OOL ING OP ER ATION Desi gn Su bco o l i n g , 7 ° F @ t he l iq ui d a cce ss f i tt ing co n n ec ti o n A H R I 95 t est co n di ti o ns. D e si g n S u p er heat 5 ° F @ t h e com pre ssor s uc tion a c c es s f i t ti ng c onne cti on. Ou t ...

  • Goodman Mfg GPC15 SEER - page 19

    19 COOLING PERFORMANCE DA T A GPC1542M41* M O DEL : GP C1 5 4 2 M 4 1 E XP A ND ED PE RF O RM A N CE DA T A C O OLI NG OP ER AT ION Desi gn Su bco o l i n g , 7 ° F @ t h e l iq ui d a cce ss f i t t in g con n ec ti o n A HR I 95 t est co n di t i o ns. D e si g n S u p er heat 5 ° F @ t h e co m p r e sso r s uc tion a c c es s f i t ti ng co n ...

  • Goodman Mfg GPC15 SEER - page 20

    20 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G PC 1548M41 EX PAN DE D P ER F OR MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss f i t t ing co n nec t i o n A HR I 95 t est co n d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com pre ssor suct i o n acc ess f it ting co n n ec t i o ...

  • Goodman Mfg GPC15 SEER - page 21

    21 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G P C 1548M41 E XP A ND E D PE RF O RM A N CE DA TA C OO LIN G OPE R A TIO N De sign S ubc ool i n g, 7 °F @ the l i qui d a c c e s s fi tt i ng c onne c ti o n AHR I 9 5 t e st c onditi ons . D e s i gn S upe r he a t 5 ° F @ t he c omp re s s or s uc ti on a cc es s f it ti ng conne c tion. O ...

  • Goodman Mfg GPC15 SEER - page 22

    22 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...

  • Goodman Mfg GPC15 SEER - page 23

    WIRING DIAGRAMS 23 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. BK BK BK BK BK BK BK ...

  • Goodman Mfg GPC15 SEER - page 24

    24 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. GPC15[24-48]M41* 3 C ...

  • Goodman Mfg GPC15 SEER - page 25

    WIRING DIAGRAMS 25 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC15[24-48]M41* 2 3 ...

メーカー Goodman Mfg カテゴリー Air Conditioner

Goodman Mfg GPC15 SEERのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GPC15 SEERの取扱説明書
- Goodman Mfgの製品カード
- パンフレット
- またはGoodman Mfg GPC15 SEERの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Goodman Mfg GPC15 SEERの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Goodman Mfg GPC15 SEERの取り付け説明書、サービスマニュアル、簡易説明書、またはGoodman Mfg GPC15 SEERのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Goodman Mfg GPC15 SEERの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Goodman Mfg GPC15 SEERデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGoodman Mfg GPC15 SEERを使用するのを助ける技術的文書のことです。説明書は通常、全てのGoodman Mfg GPC15 SEERユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Goodman Mfgの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Goodman Mfg GPC15 SEERの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGoodman Mfg GPC15 SEERの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Goodman Mfg GPC15 SEERに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Goodman Mfg GPC15 SEERデバイスの基本機能を使うにあたってのヒント。 Goodman Mfg GPC15 SEERのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Goodman Mfg GPC15 SEERに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGoodman Mfg GPC15 SEERのメーカー/サービスへの連絡先に関する情報。

Goodman Mfg GPC15 SEERについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGoodman Mfg GPC15 SEERの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGoodman Mfg GPC15 SEERで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)