Manual Graco 334014A

22 pages 4.09 mb
Download

Go to site of 22

Summary
  • Graco 334014A - page 1

    Operation Husky ™ 1050HP 2 :1 Air-Operated Diaphragm Pump 334014A EN 1–inch high-pressure pump with modular air valve for fluid transfer applic ations. For professional use only. Importan t Safety Instru ctions Read all warni ngs and inst ruction s in this manu al and in your Repair/Par ts manual. Save these instructions. Maximum F luid Workin ...

  • Graco 334014A - page 2

    Contents Re la te d Man ual s ................................................ 2 Or der in g In fo rm ati on ........................................... 3 Configuratio n Num ber M at ri x ............................... 4 Wa rni ng s ........................................................... 5 In st al la ti on.................................... ...

  • Graco 334014A - page 3

    Ordering Inform ation Ordering Info rmation To Find Your Ne arest Distributor 1. Visit www.graco. com . 2. Click on W here to Buy and use the Distribut or Locator. To Specify the Configuration of a New Pump Please call your distributor. To Order Replacement Parts Please call your distributor. Distributor N ote 1. To find part numbers for rep lace ...

  • Graco 334014A - page 4

    Con fi guration Nu mber Matrix Configuration Number Matrix Check the ident ificatio n plate ( ID) for the 20–di git Configuration Nu mber of your pum p. Use the followi ng matrix to define the components of yo ur pump. Sample Configuratio n Number: 1050HP A01A A1 SS SP SP PT Pump Model Center Section and Air Valve Manifolds Seats Balls Di a ...

  • Graco 334014A - page 5

    Warnings Warnings The following warnings are for th e setup, use, gro unding, mai ntenance, and repai r of thi s equipment . The exclamation p oint symbol alert s you to a general warni ng and the hazard symbols refer t o p rocedure- specific risks. When th ese symbols appear in the body of this manual or on warni ng labels, refer bac kt ot h e s ...

  • Graco 334014A - page 6

    Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can ca use death or seri ous injury . • Do not oper ate the unit when fatigued or und er the in fluence of drugs or al cohol. • Do not exce ed the maximum working pressur e or tempera ture rating o f the lowest r ated system compo nent. See Technical Data in all equipment manuals. • Use fluids ...

  • Graco 334014A - page 7

    Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids o r fumes can cau se serious injur y or death if splashed i n the eyes or on skin, inhaled, or s wallowed. • Read MSDSs to know the specific hazards of th e fluids you are using. • Route exhaus t away f rom work area. If diaphr agm ruptures, fluid may be exhausted in to the air. • ...

  • Graco 334014A - page 8

    Installation Installation The Typical Fl oor Mount Insta llation, page 1 2 ,i s only a gu ide fo r selecting an d installing system components. C ontact your Graco distribut or for assistance i np l a n n i n gas y s t e mt o suit your needs. Tighten Fasteners Before Setup Before usin g the pump for the first t ime, check and retorqu e a ll extern ...

  • Graco 334014A - page 9

    Installation • Air and fluid h oses: Use only ground ed hoses with a maximum of 500 ft (15 0 m) combined hose length to e nsure groundi ng conti nuity. • Air compressor: Follow manufact urer’s recommendations. • Fluid supply conta iner: Follow you r local cod e. • Solvent pail s used when flushing: Follow your local code . Use only cond ...

  • Graco 334014A - page 10

    Installation Air Exhaust Ventilation The air exhaust port is 3/4 npt( f). Do not restrict the air exhaust port. Excessive exhaust restrict ion can cause erratic pu mp operation. To provide a remote exhaust: 1. Remove the muf fler (T) fr om the pump air exhaust port. 2. Install a groun ded air exhaust hose (U ). Connec t the muffler (T) to the ot ...

  • Graco 334014A - page 11

    Installation Fluid Supply L ine See Typical Floor Mount Inst allatio n, page 12 1. Use grounded fl exibl e, fluid supply hoses (G). See Groundin g, page 8 . 2. If the inlet fl u i dp r e s s u r et ot h ep u m pi sm o r e than 25% of th e outlet working pres sure, the ball check valves will no t close fast enough, r esulting in inefficie nt pum ...

  • Graco 334014A - page 12

    Installation Typical Floor Mount Installation Figure 3 Typical floor mount install ation KEY A Air supply line J Fluid drain valve (requ ired) B Bleed-type master air valve (re quired for pump) K Fluid shuto ff valve C Air fi lter and regul ator L Flex ible fluid outlet hose D Air inlet M Fluid inl et (2 ports on alumin um manifolds, 1 port on S ...

  • Graco 334014A - page 13

    Operation Operation Pressure Reli ef Procedure Follow the P r essure Relief Procedure whenever you see this symbol. This equip m ent stays pressurized until pressu re is relieved manually. To help prevent serious injury from pressurized fluid, such as spl ashing in the eyes or on skin, fo llow the Pressure Relief Procedure when you stop pum ping a ...

  • Graco 334014A - page 14

    Operation Start and Adju st the Pump 1. Be sure the pump is properly grounde d. Refer to Grounding, page 8 . 2. Ensure the High/Low pressur e lever is in the “Low” positio n before start ing the pump. 3. Check all fitt ings to be sure t hey are tight . Use a compatibl e liquid thr ead sealan t on all male threads. Tighten fluid inlet and out ...

  • Graco 334014A - page 15

    Maintenance Maintenance Maintenance Schedule Establish a p reventive maintenance schedul e, based on the p ump’s service history. Scheduled maintenance is especially important to pre vent spills or leakage d ue to dia phragm failur e. Lubrication T h ep u m pi s lubri cated at the factory. It is designed to require no further lubrication for the ...

  • Graco 334014A - page 16

    Maint enanc e Torque Instructions NOTE: All fast eners for the fluid covers, center diaphragm joi nt, and manifolds have a thread-l ocking adhesive patc h a pplied t o the thread s. If t his patch i s excessively w orn, the fasteners may loosen during operation. R eplace screws with new ones or apply medium-stre ngt h (blue) Loctit e or equival en ...

  • Graco 334014A - page 17

    Dimen sions and M ounting Dimensions and Mounting KEY Aluminum SST Aluminum and SST A 12.7 in (323 mm) 11.8 in (300 mm) H 6.2 in (157 mm) B 14.4 in (366 mm) 12.9 in (328 mm) J 9.4 in (239 mm) C 15.3 in (389 mm) 13.7 in (348 mm) K 15.6 in (396 mm) D 10.9 in ( 277 mm) 9.5 in (241 mm) L 3/4 npt(f) Air Inl et E 1.8 in (46 mm) 1.1 in (28 mm) M 1 in npt( ...

  • Graco 334014A - page 18

    Performance Cha rts Performance C harts Low Pressure S etting Fluid Pres sure Approximate Cycle s per Minute PSI (MPa, bar) 0 20 (0.14, 1.4) 40 (0.28, 2.8) 60 (0.41, 4.1) 80 (0.55, 5.5) 100 (0.70, 7.0) 01 0 (38) 20 (76) 30 (1 14) 40 (151) 50 (189) 56 1 12 168 224 280 A B C D Fluid Flow — gpm (lpm) Operating Air Pr essure A 100 psi (0.7 MPa, 7.0 b ...

  • Graco 334014A - page 19

    Performa nce Cha rts High Pressure Setting Fluid Pressure Approximate Cycles pe r Minute PSI (MPa, bar) 0 40 (0.28, 2.8) 80 (0.55, 5.5) 120 (0.83, 8.3) 160 (1.10, 1 1.0) 200 (1.38, 13.8) 01 0 (38) 20 (76) 30 (1 14) 40 (151) 50 (189) 50 100 150 200 250 A B C D Fluid Flow — gpm (l pm) Operating Air Pres sure A 100 psi (0.7 MPa, 7.0 bar) B 70 psi (0 ...

  • Graco 334014A - page 20

    Technical Data Technical Data US Metric Maximum fluid workin g pressure 200 psi 1.4 MPa,14.0 b ar Air pressure o peratin g range 20-100 psi 0.14-0. 69 MPa , 1.4-6.9 b ar Fluid displa cement per cycle Low Pressu re Setting 0.17 g 0.64 l High Pressure Setting 0.20 g 0.76 l Air consumpt ion at 70 psi, 20 gpm at 4.8 bar, 76 lpm Low Pressure Setting 26 ...

  • Graco 334014A - page 21

    Technical Data Sound Power (measure d per ISO-9614–2) At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm Low Pressure Setting 78 dBa High Pressure Setting 91 dBa At 100 psi (0.7 MPa, 7.0 bar) and ful l flow Low Pressure Setting 90 dBa High Pressure Setting 102 d Ba Sound Pressure ( t e s t e d3 . 2 8f t[ 1m ]f r o me q u i p m e n t ) At 70 psi (0.48 MPa, ...

  • Graco 334014A - page 22

    Graco Standard Husky Pump Warranty Graco warrants all equipment r eferenced i n this documen t which is manuf ac tured by Graco and bear ing its name to be free from defect s in material and workmanshi p on the date of sale t o the original purchase r for use. With the exception of any speci al, extended, or li mited warranty publ ished by Graco, G ...

Manufacturer Graco Category Marine Sanitation System

Documents that we receive from a manufacturer of a Graco 334014A can be divided into several groups. They are, among others:
- Graco technical drawings
- 334014A manuals
- Graco product data sheets
- information booklets
- or energy labels Graco 334014A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Graco 334014A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Graco 334014A, service manual, brief instructions and user manuals Graco 334014A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Graco 334014A.

Similar manuals

A complete manual for the device Graco 334014A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Graco 334014A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Graco 334014A.

A complete Graco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Graco 334014A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Graco 334014A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Graco 334014A, that we can find in the current document
3. Tips how to use the basic functions of the device Graco 334014A - which should help us in our first steps of using Graco 334014A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Graco 334014A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Graco 334014A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Graco 334014A?

Use the form below

If you did not solve your problem by using a manual Graco 334014A, ask a question using the form below. If a user had a similar problem with Graco 334014A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)