Manual GE AS_06

32 pages 1.32 mb
Download

Go to site of 32

Summary
  • GE AS_06 - page 1

    Safety Information Safety Precautions . . . . . . . .3 How to Connect Electricity . . . . . . . . . . . . . . . .3 Use of Extension Cords . . .4 Use of Adapter Plugs . . . . . .4 Operating Instructions Models with Touch Pads 5, 6 Models with Control Knobs . . . . . . . . .7, 8 Care and Cleaning Grille and Case . . . . . . . . . . .9 Outdoor Coils . ...

  • GE AS_06 - page 2

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions FOR YOUR RECORDS Write the model and serial numbers here: # # You can find them on a label on the side of the air conditioner. Staple sales slip or cancelled check here. Proof of the original purchase date is needed to obtain service under t ...

  • GE AS_06 - page 3

    IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury . ■ Use this appliance only for its intended purpose as described in this Owner’s Manual. ■ This air conditioner must be properly instal ...

  • GE AS_06 - page 4

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 4 IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord. However, if you must use an extension c ...

  • GE AS_06 - page 5

    ■ To ensure proper operation, aim the remote control at the signal receiver on the air conditioner. ■ The remote control signal has a range of up to 21 feet. ■ Make sure nothing is between the air conditioner and the remote control that could block the signal. ■ Make sure batteries are fresh and installed correctly–see the Care and Cleani ...

  • GE AS_06 - page 6

    6 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions About the controls on ...

  • GE AS_06 - page 7

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions About the controls on the air conditioner–models with control knobs. Features and appearance will vary . Controls Mode Controls HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds. LOW FAN or HIGH FAN provides air ci ...

  • GE AS_06 - page 8

    8 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions About the controls on ...

  • GE AS_06 - page 9

    Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary. T o remove (on some models): Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and ...

  • GE AS_06 - page 10

    10 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Preparing to install ...

  • GE AS_06 - page 11

    Parts Included Type A (9) Security bracket (3) Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B (8) Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 11 Window Installation Instructions for 5000 BTU Units (model AS_05) ■ Phillips- ...

  • GE AS_06 - page 12

    Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES— WIDTH: 2 ″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood o ...

  • GE AS_06 - page 13

    Prepare the Air Conditioner Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Install the top mounting rail with 3 type A screws from the outside of the case. Loosen the lower screw on each side of the case and hook a security bracket on each side. Tighten the screws to secure the bracket ...

  • GE AS_06 - page 14

    Install the Air Conditioner in the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash. Place the air conditioner on the stool with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the o ...

  • GE AS_06 - page 15

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 15 Read the section Preparing to Install the Air Conditioner before beginning. Parts Included Type A AS_06, AS_08 (17) AS_10 (19) Sill support (2) Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion ...

  • GE AS_06 - page 16

    Window Installation Instructions for 6000, 8000, and 10,000 BTU Units (models AS_06, AS_08, and AS_10) Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES— WIDTH: 2 ″ LENGTH: Lon ...

  • GE AS_06 - page 17

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Prepare the Case Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Install the top mounting rail with 3 type A or 5 type A screws (as the installation requires) from the inside of ...

  • GE AS_06 - page 18

    Install the Case in the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash. Thread two type C bolts into the support brackets. Slide the case into the window and lower the window behind the top mounting rail. Position the brackets on the case bottom so they will be near the outermost point on t ...

  • GE AS_06 - page 19

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 19 Install the Air Conditioner in the Case Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Place the bottom inner case gasket between the bottom of the air conditioner and the inside ...

  • GE AS_06 - page 20

    20 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Read the section Pre ...

  • GE AS_06 - page 21

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 21 Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES— WIDTH: 2 ″ LE ...

  • GE AS_06 - page 22

    Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) Prepare the Case Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Install the top mounting rail with 8 type A screws from the inside of ...

  • GE AS_06 - page 23

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Prepare the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash. Mark the centerline of the stool. Measure and mark the locations for the support assemblies 12 3 ⁄ 8 ″ from both sides ...

  • GE AS_06 - page 24

    Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) 24 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions ...

  • GE AS_06 - page 25

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 25 Install the Air Conditioner in the Case Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Place the bottom inner case gasket between the bottom of the air conditioner and the inside ...

  • GE AS_06 - page 26

    26 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Through the W all In ...

  • GE AS_06 - page 27

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Before you call for service… T roubleshooting T ips: Save time and money! Review the chart below first and you may not need to call for service. Normal Operating Sounds ■ You may hear a pinging noise caused by water being picked up and t ...

  • GE AS_06 - page 28

    28 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Notes ...

  • GE AS_06 - page 29

    General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150 GE Service Protection Plus ™ GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™ —comprehensive protection on all your appliances— No Matter What Brand! Benefits Include: • Backed by GE • All ...

  • GE AS_06 - page 30

    Consumer Product Ownership Registration Important Mail Today! First Name Mr. ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Year Zip Code Apt. # Last Name Phone Number _ _ Consumer Product Ownership Registration Dear Customer: Thank you for purchasing our product and thank you for placing your c ...

  • GE AS_06 - page 31

    31 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Air Conditioner W arranty All warranty service provided by our Factory Service Centers, or an authorized Customer Care ® technician. For service, call 800-GE-CARES. For The Period Of: W e Will Replace: One Y ear Any part of the air condi ...

  • GE AS_06 - page 32

    Operating Instructions Safety Instructions Installation Instructions T roubleshooting T ips Customer Service Service T elephone Numbers. GE Answer Center ® 800.626.2000 The GE Answer Center® is open 24 hours a day, 7 days a week. In-Home Repair Service 800-GE-CARES (800-432-2737) Expert GE repair service is only a phone call away. Special Needs S ...

Manufacturer GE Category Air Conditioner

Documents that we receive from a manufacturer of a GE AS_06 can be divided into several groups. They are, among others:
- GE technical drawings
- AS_06 manuals
- GE product data sheets
- information booklets
- or energy labels GE AS_06
All of them are important, but the most important information from the point of view of use of the device are in the user manual GE AS_06.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals GE AS_06, service manual, brief instructions and user manuals GE AS_06. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product GE AS_06.

Similar manuals

A complete manual for the device GE AS_06, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use GE AS_06 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of GE AS_06.

A complete GE manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual GE AS_06 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the GE AS_06, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the GE AS_06, that we can find in the current document
3. Tips how to use the basic functions of the device GE AS_06 - which should help us in our first steps of using GE AS_06
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with GE AS_06
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of GE AS_06 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning GE AS_06?

Use the form below

If you did not solve your problem by using a manual GE AS_06, ask a question using the form below. If a user had a similar problem with GE AS_06 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)