    Safety Information Safety Precautions . . . . . . . .3 How to Connect Electricity . . . . . . . . . . . . . . . .3 Use of Extension Cords . . .4 Use of Adapter Plugs . . . . . .4 Operating Instructions Models with Touch Pads 5, 6 Models with Control Knobs . . . . . . . . .7, 8 Care and Cleaning Grille and Case . . . . . . . . . . .9 Outdoor Coils . ...

  • GE AS_06 - page 2

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions FOR YOUR RECORDS Write the model and serial numbers here: # # You can find them on a label on the side of the air conditioner. Staple sales slip or cancelled check here. Proof of the original purchase date is needed to obtain service under t ...

  • GE AS_06 - page 3

    IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury . ■ Use this appliance only for its intended purpose as described in this Owner’s Manual. ■ This air conditioner must be properly instal ...

  • GE AS_06 - page 4

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 4 IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord. However, if you must use an extension c ...

  • GE AS_06 - page 5

    ■ To ensure proper operation, aim the remote control at the signal receiver on the air conditioner. ■ The remote control signal has a range of up to 21 feet. ■ Make sure nothing is between the air conditioner and the remote control that could block the signal. ■ Make sure batteries are fresh and installed correctly–see the Care and Cleani ...

  • GE AS_06 - page 6

    6 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions About the controls on ...

  • GE AS_06 - page 7

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions About the controls on the air conditioner–models with control knobs. Features and appearance will vary . Controls Mode Controls HIGH COOL, MED COOL and LOW COOL provide cooling with different fan speeds. LOW FAN or HIGH FAN provides air ci ...

  • GE AS_06 - page 8

    8 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions About the controls on ...

  • GE AS_06 - page 9

    Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary. T o remove (on some models): Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. CAUTION: DO NOT operate the air conditioner without a filter because dirt and lint will clog it and ...

  • GE AS_06 - page 10

    10 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Preparing to install ...

  • GE AS_06 - page 11

    Parts Included Type A (9) Security bracket (3) Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B (8) Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 11 Window Installation Instructions for 5000 BTU Units (model AS_05) ■ Phillips- ...

  • GE AS_06 - page 12

    Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES— WIDTH: 2 ″ LENGTH: Long enough to fit inside the window frame. THICKNESS: To determine the thickness, place a piece of wood o ...

  • GE AS_06 - page 13

    Prepare the Air Conditioner Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Install the top mounting rail with 3 type A screws from the outside of the case. Loosen the lower screw on each side of the case and hook a security bracket on each side. Tighten the screws to secure the bracket ...

  • GE AS_06 - page 14

    Install the Air Conditioner in the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash. Place the air conditioner on the stool with the bottom mounting rail against its back edge. Center it and close the window securely behind the top mounting rail. It should be level or slightly tilted to the o ...

  • GE AS_06 - page 15

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 15 Read the section Preparing to Install the Air Conditioner before beginning. Parts Included Type A AS_06, AS_08 (17) AS_10 (19) Sill support (2) Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion ...

  • GE AS_06 - page 16

    Window Installation Instructions for 6000, 8000, and 10,000 BTU Units (models AS_06, AS_08, and AS_10) Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES— WIDTH: 2 ″ LENGTH: Lon ...

  • GE AS_06 - page 17

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Prepare the Case Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Install the top mounting rail with 3 type A or 5 type A screws (as the installation requires) from the inside of ...

  • GE AS_06 - page 18

    Install the Case in the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash. Thread two type C bolts into the support brackets. Slide the case into the window and lower the window behind the top mounting rail. Position the brackets on the case bottom so they will be near the outermost point on t ...

  • GE AS_06 - page 19

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 19 Install the Air Conditioner in the Case Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Place the bottom inner case gasket between the bottom of the air conditioner and the inside ...

  • GE AS_06 - page 20

    20 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Read the section Pre ...

  • GE AS_06 - page 21

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 21 Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool. WOOD PIECES— WIDTH: 2 ″ LE ...

  • GE AS_06 - page 22

    Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) Prepare the Case Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail. Install the top mounting rail with 8 type A screws from the inside of ...

  • GE AS_06 - page 23

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Prepare the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash. Mark the centerline of the stool. Measure and mark the locations for the support assemblies 12 3 ⁄ 8 ″ from both sides ...

  • GE AS_06 - page 24

    Window Installation Instructions for 12,000, 14,000, 16,000, 18,000, 22,000, and 24,000 BTU Units (models AS_12, AS_14, AS_16, AS_18, AS_22, and AS_24) 24 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions ...

  • GE AS_06 - page 25

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 25 Install the Air Conditioner in the Case Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Place the bottom inner case gasket between the bottom of the air conditioner and the inside ...

  • GE AS_06 - page 26

    26 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Through the W all In ...

  • GE AS_06 - page 27

    Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Before you call for service… T roubleshooting T ips: Save time and money! Review the chart below first and you may not need to call for service. Normal Operating Sounds ■ You may hear a pinging noise caused by water being picked up and t ...

  • GE AS_06 - page 28

    28 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Customer Service T roubleshooting T ips Installation Instructions Safety Instructions Operating Instructions Notes ...

  • GE AS_06 - page 29

    General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150 GE Service Protection Plus ™ GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™ —comprehensive protection on all your appliances— No Matter What Brand! Benefits Include: • Backed by GE • All ...

  • GE AS_06 - page 30

    Consumer Product Ownership Registration Important Mail Today! First Name Mr. ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Year Zip Code Apt. # Last Name Phone Number _ _ Consumer Product Ownership Registration Dear Customer: Thank you for purchasing our product and thank you for placing your c ...

  • GE AS_06 - page 31

    31 Customer Service T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Air Conditioner W arranty All warranty service provided by our Factory Service Centers, or an authorized Customer Care ® technician. For service, call 800-GE-CARES. For The Period Of: W e Will Replace: One Y ear Any part of the air condi ...

  • GE AS_06 - page 32

    Operating Instructions Safety Instructions Installation Instructions T roubleshooting T ips Customer Service Service T elephone Numbers. GE Answer Center ® 800.626.2000 The GE Answer Center® is open 24 hours a day, 7 days a week. In-Home Repair Service 800-GE-CARES (800-432-2737) Expert GE repair service is only a phone call away. Special Needs S ...

Производитель GE Категория Air Conditioner

Документы, которые мы получаем от производителя устройства GE AS_06 мы можем разделить на несколько групп. Это в частности:
- технические чертежи GE
- инструкции обслуживания AS_06
- паспорта изделия GE
- информационные брошюры
- энергетические этикетки GE AS_06
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания GE AS_06.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа GE AS_06, инструкции обслуживания, короткие инструкции или инструкции пользователя GE AS_06. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия GE AS_06.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства GE AS_06, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании GE AS_06 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей GE AS_06.

Полная инструкция обслуживания GE, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией GE AS_06 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания GE AS_06, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся GE AS_06, которое найдем в данном документе
3. Советы по использованию основных функций устройства GE AS_06 - которые должны облегчить нам первые шаги во время использования GE AS_06
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем GE AS_06
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра GE AS_06 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся GE AS_06?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с GE AS_06, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с GE AS_06 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)