  • Omega HH501AT - page 1

    OMEGA HH501A T Digital Thermometer ...

  • Omega HH501AT - page 2

    OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com Ser vicing Nor th America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com ome ...

  • Omega HH501AT - page 3

    1 The symbol on the instrument indicates that the operator must refer to an explanation in this manual. WARNING To avoid electrical shock, do not use this instrument when working voltages at the measurement surface over 24V AC or DC. WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. CAUTION Repeated sharp fle ...

  • Omega HH501AT - page 4

    SPECIFICATIONS ELECTRICAL Temperature Scale: Celsius or Fahrenheit user-selectable. Measurement Range: -200°C to 400°C, -328°F to 752°F Resolution: 0.1°C , 0.1°F (-59.9°C to 199.9°C ,-59.9°F to 199.9°F) 1°C , 1°F on other range Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), ...

  • Omega HH501AT - page 5

    3 ENVIRONMENTAL Ambient Operating Ranges: 0°C to 50°C (32°F to 122°F) <80% R.H. Storage Temperature: -20°C to 60°C (-4°F to 140°F) <70% R.H. GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overload: "-OL" is display. Battery: Standard 9V battery. Battery Life: 100 hours typical. Auto pow ...

  • Omega HH501AT - page 6

    OPERATING INSTRUCTIONS Power Switch The key turns the thermometer on or off. In the MIN MAX record mode can not power off, must leave MIN MAX record mode then power off. °C °F Selecting the Temperature Scale Readings is displayed in either degrees Celsius(°C) or degrees Fahrenheit(°F). When the thermometer is turned on, it is set to the tempera ...

  • Omega HH501AT - page 7

    MIN MAX record Mode Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading, Minimum reading, "MAX-MIN" reading and Average reading stored in record mode). In the this mode the automatic power-off feature is disabled and key and all function key are disabled.The beeper emits a tone when a new minimum or maximu ...

  • Omega HH501AT - page 8

    REL Relative mode (only Main display) Pressing REL key to enter the Relative mode, zero the display, and store the displayed Reading as a reference value and annunciator REL is displayed. Press REL key again to exit the relative mode. The relative value can also be entered by the user. (See "SET mode" later in this manual.) When the desir ...

  • Omega HH501AT - page 9

    7 12 (Press ENTER key can escape Lo Limit value set mode), _ = = =.= is displayed (the ".=" is displayed when you set up the fourth number), Lo Limit value is entered via overlay numbers, when you want to get negative values push (- 0) key for end of numbers, then press overlay ENTER key, stored the Lo Limit value and exit set mode. 3. In ...

  • Omega HH501AT - page 10

    8 OPERATOR MAINTENANCE WARNING To avoid possible electrical shock, disconnect the thermocouple connectors from the thermometer before removing the cover. Battery Replacement Power is supplied by a 9 volt "transistor" battery. The " " appears on the LCD display when replacement is needed. To replace the battery, remove the two sc ...

  • Omega HH501AT - page 11

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC . warrants this unit to be free of def ects in mater ials and w orkmanship for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month gr ace period to the nor mal one (1) year pr oduct warranty to cover handling and shipping time . This ensures that OMEGA's cu ...

  • Omega HH501AT - page 12

    M-2819/0799 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE þ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD & Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process Monitors þ Infrared Pyromet ...

Manufacturer Omega Category Thermometer

Documents that we receive from a manufacturer of a Omega HH501AT can be divided into several groups. They are, among others:
- Omega technical drawings
- HH501AT manuals
- Omega product data sheets
- information booklets
- or energy labels Omega HH501AT
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega HH501AT.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega HH501AT, service manual, brief instructions and user manuals Omega HH501AT. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega HH501AT.

Similar manuals

A complete manual for the device Omega HH501AT, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega HH501AT by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega HH501AT.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega HH501AT - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega HH501AT, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega HH501AT, that we can find in the current document
3. Tips how to use the basic functions of the device Omega HH501AT - which should help us in our first steps of using Omega HH501AT
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega HH501AT
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega HH501AT in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega HH501AT?

Use the form below

If you did not solve your problem by using a manual Omega HH501AT, ask a question using the form below. If a user had a similar problem with Omega HH501AT it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)