    Installation Operation & Maintenance WSHPC-IOM-2 72-9041-02 Library Service Literature Product Section Unitary Product W ater Source Heat Pump Model GSSD Literatur e T ype Installation, Operation and Maintenance Sequence 2 Date June 1999 File No. SL-UN-WSHP-GSSD-I OM-2-6-99 Supersedes WSHPC-IOM-2 / 72- 9041-01 (Jan 98) Water Source Heat Pump Re ...

  • Trane GSSD - page 2

    2 Model Number Descriptions.............. ....... 3 Installation (W ater Loop).. 15 General Information............ .......... 4 Refrigeration Charge........ 16 Receiving and Handling.............. ............ 6 Refrigeration System....... 17 Installatio n Drawings............. ............ 7 Accessories....... ........... . 18 Installatio n (W at ...

  • Trane GSSD - page 3

    3 DIGITS 1 & 2 - PRODUCT TYPE GS = Ground Source Heat Pump DIGIT 3 - PRODUCT CONFIGU- RATION S = Split System DIGIT 4 - DEVELOPMENT SE- QUENCE D DIGITS 5,6 & 7 - UNIT NOMINAL CAPACITY (MBH) 024 = 24.1 030 = 29.6 036 = 36.4 042 = 41.1 048 = 48.7 060 = 59.2 072 = 65.6 DIGIT 8 - VOLTAGE/HERTZ/ PHASE 1 = 208/230-60-1 DIGIT 9 - UNIT ARRANGEM ENT ...

  • Trane GSSD - page 4

    4 The GSSD split unit has been ARI rat- ed with the Trane TWE air handlers with ICM 2 variab le speed motors to create a complete split system for res- idential applications. The GSSD equipment is completel y assembled, piped, inte rnally wire d and test operat- ed in the factory. The GSSD equip- ment is ETL and CSA listed. A prewired terminal stri ...

  • Trane GSSD - page 5

    5 Wa r r a n t y The unit is warranted by the manufac- turer against any defects in material and factory workmanship for one year after installation (labor and parts) . The refrigerant circuit, including the compressor, expansion device, revers- ing valve (less solenoid coil) , and all heat exchangers in contact with refrig- erants are warranted fo ...

  • Trane GSSD - page 6

    6 The GSSD is packaged in clear stretch wrap to allow immediate visual in- spection. A careful inspecti on should be made for shipping damage. All o r- ders are free on board (FOB) facto- ry, therefore claims must be made with the delivering carrier. Carefully remove the stretch wrap and the top cardboard corner pieces. Also remove the (4) four shi ...

  • Trane GSSD - page 7

    7 Installation-Location Considerations 23-5/16” 23” TOP VIEW 24-5/16” 24-13/16” 8 -7/16” 13-1/4” 2-1/16” 13-15/16” 7-3/16” 14-3/4” WATER IN-1” NPTI WATER OUT 1” NPTI LIQUID LINE 1/2” O.D . HI VOLTAGE 1-1/8” DIA. 6-7/16” 5-1/2” 3-15/16” 1-7/16” LOW VOLTAGE 1-1/8” DIA . PUMP CONTROL 1-1/8” DIA . SUCTION/DISCH 3 ...

  • Trane GSSD - page 8

    8 Installation-Location Considerations 23-5/16” 23” TOP VIEW 24-5/16” 24-13/16” 8 -7/16” 11-1/2” 2-1/16” 13” 7-3/16” 14-3/4” WATER IN-1” NPTI WATER OUT 1” NPTI LIQUID LINE 1/2” O.D . HI VOLTAGE 1-1/8” DIA. 6-7/16” 5-1/2” 3-15/16” 1-7/16” LOW VOLTAGE 1-1/8” DIA . PUMP CONTROL 1-1/8” DIA . SUCTION/DISCH 3/4” ...

  • Trane GSSD - page 9

    9 23-5/16” 23” TOP VIEW 24-5/16” 24-13/16” 8 -7/16” 11-1/2” 2-1/16” 7-3/16” 14-3/4” WATER IN-1” NPTI WATER OUT 1” NPTI LIQUID LINE 1/2” O.D . HI VOLTAGE 1-1/8” DIA. 6-7/16” 5-1/2” 3-15/16” 1-7/16” LOW VOLTAGE 1-1/8” DIA . PUMP CONTROL 1-1/8” DIA . SUCTION/DISCH 3/4” O.D. WATER REG (SCHRADER PORT) DESUPER OUT ...

  • Trane GSSD - page 10

    10 Installation-Water Connections Location Consideration ! Unit should be placed on a level surface in a indoor protected area. Units should not be installed or stored in an exterior environment. ! There should be approximately 2 to 3 feet of clearance available for accessing the unit for service. Accessiblity into unit is made by re- moving (2) tw ...

  • Trane GSSD - page 11

    11 RF Y 2 OC RG Y O B W 1 W 2 34 5 6 1 T-Stat (X13510588 020) Manual changeover: -two-stage heat -one-stage co ol TWE (Sizes 031-065) GSSD (Sizes 024-072) GSSD 24V Field Wiring W 1 W 2 Compressor Reversing valve (energized 5 6 in cooling) Field Wiring Connections Power wiring to the unit should be in- stalled per local electric codes by a professio ...

  • Trane GSSD - page 12

    12 . T able 1: Electrical Data Unit Model: GSSD 024 030 036 042 048 060 072 Electrical V olts-60HZ/1Phase 208-230 208-230 208-230 208-230 208-230 208-230 208-2 30 Compr essor RLA 1 1.4 13.6 15 18.4 20.4 28 32.1 Compr essor LRA 56 67 73 95 109 169 169 Blower Motor RLA 3 5 5.6 5.6 5.6 7.4 7.4 Min. Cir cuit Amp. 14.7 17.4 19.2 23.4 25.9 35.4 40.5 Max ...

  • Trane GSSD - page 13

    13 Press ure Switch A high pressure switch is provided to protect the compress or against exces- sive refrigeration pressure. The low pressure switch should b e wired in ac- cordance with the type of freezestat that is used. Trane factory supplies two low pressure switches in the re- frigerant circuit. The electrical con- nection is dependant upon ...

  • Trane GSSD - page 14

    14 L1 L2 1K1 L3 T3 1K1 L1 T1 5F3 5F2 230V 6A MAX TO WATERSOURCE PUMP A,C 6A,C,D,E C 7C 1C1 6E 4 5F1 2A 6F 5C A 7A A R S C 2B1 4S5 6G 4S6 6H DESUPE R- HEATER PUMP 6B1 5C 1TB3-1 16 F,G 1TB3-5 18 1TB3-6 25 1K3 C2 C1 A 1K3 5 19A 4S3 20A 4S4 4S1 21A A 4S4 23 1TB3-7 C A F 1TB3-8 23 A 16 1TB3-2 1K1 D,F D 1K3-24 G 1K1-12,14 NOTES: 1. UNLESS OTHERWISE NOTED ...

  • Trane GSSD - page 15

    15 Loop W ater Applications It should be noted that there is no me- chanical differen ce between geother- mal (closed loop) and ground water (open loop) GSSD units. General ly in a closed loop application, there is a percentage of antifreeze in the water. In these applications, the 20 degree F freezestat, along with the 7 psig safety pressure switc ...

  • Trane GSSD - page 16

    16 GSSD Units Coupled with TWE Air Handlers The GSSD IS coupled with the TWE- E series. Table 4 may be used to det er- mine the amount of charge necessary for the split unit system withou t any refrigerant line connecting the two. Table 5 can be used to determine the amount of refrigerant needed for lines. By adding the two weights toget her, the a ...

  • Trane GSSD - page 17

    17 Refrigeration System ! Compr essor: The unit includes a high efficiency scroll compressor with and internal v ibration isolator that absorbs start ing and stopping energy . It also contains an internal overload protection. External vibration isolatio n is provided by rubber mounting devices located underneath the mounting base of the compressor ...

  • Trane GSSD - page 18

    18 Accessory Items Note: The following eq ui pment may be pur- chased thr ough the near est T rane dis- tributor . ! W ater Regulating V alve Assembly : The water regulating valve assembly consists of a direct acting valve and a reverse acting valve. The direct acting valve opens in response to an increase in discharge pressure during the cooling c ...

Manufacturer Trane Category Heat Pump

Documents that we receive from a manufacturer of a Trane GSSD can be divided into several groups. They are, among others:
- Trane technical drawings
- GSSD manuals
- Trane product data sheets
- information booklets
- or energy labels Trane GSSD
All of them are important, but the most important information from the point of view of use of the device are in the user manual Trane GSSD.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Trane GSSD, service manual, brief instructions and user manuals Trane GSSD. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Trane GSSD.

Similar manuals

A complete manual for the device Trane GSSD, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Trane GSSD by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Trane GSSD.

A complete Trane manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Trane GSSD - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Trane GSSD, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Trane GSSD, that we can find in the current document
3. Tips how to use the basic functions of the device Trane GSSD - which should help us in our first steps of using Trane GSSD
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Trane GSSD
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Trane GSSD in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Trane GSSD?

Use the form below

If you did not solve your problem by using a manual Trane GSSD, ask a question using the form below. If a user had a similar problem with Trane GSSD it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)