    Operation Manual LRM 1500M / LRM 1800S LASER RANGEFINDER MONOCULAR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada ...

  • Newcon Optik LRM 1500M - page 2

    ...

  • Newcon Optik LRM 1500M - page 3

    IMPORTANT INFORMATION Read prior to activa tion You have just purc hased a sophisticat ed electro-opti cal device that em its invisible l aser radiat ion. To operate it properly, please, read this m anual carefully.  NEVER direct laser beam at the eyes of pe ople or animals  NEVER aim the unit at the Sun or bright so urces of light  NEVER ...

  • Newcon Optik LRM 1500M - page 4

     Avoid eye exposure to direct laser beam or its close reflection  Prevent bri ght light from foc ussing th rough the eyepiece  Never aim the unit at highly reflective objects like mirrors and retroreflective surfaces, which are in close proximity to the laser rangefinder. This can lead to the permanent da mage of the photoreceiver incorpor ...

  • Newcon Optik LRM 1500M - page 5

    1 TABLE OF CONTENTS 1. BRIEF DESCRIPTIO N ............................................ 2 1.1 Principle of operation........................................... 2 1.2 Key Featur es ........................................................ 3 2. DEVICE APPE ARANCE ........................................ 4 3. DELIVERY S ET .............................. ...

  • Newcon Optik LRM 1500M - page 6

    2 CAREFULLY READ ALL THE I NSTRUCTIONS BEFORE USING THE UNIT! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANT Y AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTION LRM 1500M / 1800S La ser Rangefinder Monocular is an advanced laser range finder system that enables instant distance and speed (1800S modification only) m easurement. The unit complies wi ...

  • Newcon Optik LRM 1500M - page 7

    3 Key Features  Distance is displayed in meters or yards  Original digital circuitry allows ranging through most types of glass, bushe s and other obs tacles  Three channel optical solution (optical, laser a nd receiver) provides high accuracy  Two reticle shapes: -¦- or   Target quality display indicator assures that results are ...

  • Newcon Optik LRM 1500M - page 8

    4 2 3 4 5 6 7 1 8 2. DEVICE APPEARANCE Fig. 1. Front view 1 - Eyepiece 2 - Objective lens 3 - Laser em itter lens 4 - Receiver lens 5 - M (Mo de) button 6 - A (Acti on) but ton 7 - Body of the de vice 8 - Rubber g rip ...

  • Newcon Optik LRM 1500M - page 9

    5 Fig.2. Rear view 1 - Eyepiece 9 - Battery compartment cover 10 - Tripod socket 11 - Identification imprint 12 - Classification imprint, shown b elow 9 11 1 12 10 ...

  • Newcon Optik LRM 1500M - page 10

    6 3. DELIVERY SET Standard delivery set LRM 1500M / 1800S is supplied in the following assembly: Qty LRM 1 9V Alkaline battery 1 Soft carrying c ase 1 Neck strap 1 Operation m anual 1 Warranty card 1 ...

  • Newcon Optik LRM 1500M - page 11

    7 4. SPECIFICATION S Optics Magnificatio n Objective lens diameter Exit pupil diameter Field of view Type of coating 7x 25 mm 3.6 mm 8  Fully multi-coated optics Range Finder Laser Measuring range, LRM 1500M Measuring range, LRM 1800S Accuracy Meters/Yards display Last 10 readings recall Reticle Target quality indicator Class 1, eye safe, 905 nm ...

  • Newcon Optik LRM 1500M - page 12

    8 Speed Detector (LRM 1800S only) Measured spee d range 5-400 km /h Accuracy ±2 km/h Power Battery 9V 'Low Batte ry' indicato r Yes Environmental Operational temperature range Storage temperature range -25 / +50 o C (-13 / +122 o F) -45 / +65 o C (-49 / +149 o F) Mechanics Tripod thread Weight without battery Dimensi ons ¼” x 20 445 g ...

  • Newcon Optik LRM 1500M - page 13

    9 5. OPERATION INSTRUCTIONS 1 – Low battery indi cator 2 – Reticle (either -¦- or  ) 3 – Units of measurem ent 4 – Measurement resul t 5 – Target q uality i ndicator 6 – Lase r active indicat or 7 – Setup m ode indicat or 8 – Ready mode indicat or 4 6 2 1 3 8 7 Fig. 3. Liquid Crystal Display as seen through the eyepiece 5 ...

  • Newcon Optik LRM 1500M - page 14

    10 Changing b attery To install a battery:  Slide the battery compartm en t cover down (9, Fig. 2)  Install the battery observing polarity  Don’t appl y superfluou s strength while push ing the bat tery inside the compartment.  Close the compartment cove r If the battery does not fit the compartment easily, it means that polarity was ...

  • Newcon Optik LRM 1500M - page 15

    11 Measuring procedure To start the m easuring proced ure, remove t he lens co ver. Look through the eyepi ece (1, Fig. 1, 2) a nd ad just the focus by its rotating. When the Rangefi nder is off th e LCD is blank. To activate it press and hold A butto n (6, Fig. 1) for half a second. At star t the unit comes into Read y to Measure mode indicated by ...

  • Newcon Optik LRM 1500M - page 16

    12 Target reflectivity depends on its c olor, surface finish, size, shape, position in relation to the laser beam, etc. Bright target colors are more reflective tha n darks. A polished surface is m ore reflective than a rough one. L arger targets reflect better t han small ones. Ra nging a t arget perpe ndicular t o the laser beam provides better r ...

  • Newcon Optik LRM 1500M - page 17

    13 KMH/MPH : units of spee d measurement: km/hour or miles/hour ( 3, Fig.3) (LRM 1 800S only). Shape of the reticle: cross shape or rectangu lar sha pe (2, Fig.3). rEC1: Data Recall mode. It returns results of the last 10 measurements on the display. Measurement results are save d in on-board memor y. When you enter the Data Recall m ode, first m e ...

  • Newcon Optik LRM 1500M - page 18

    14 Additional di splay inf ormation Distance measuring procedure in cludes inst ant statistical processing of the package of si ngle measuri ng sessions. If there is more than one m easured targ et in the field of view, the embedded software estim ates the m ost prob able one by calculating the number of reflected pulses multiplied by the target st ...

  • Newcon Optik LRM 1500M - page 19

    15 6. STORAGE AN D MAINTENANCE The unit is a s ophisticated precisi on optical i nstrument equi pped with laser and electronics. Ther efore, it should be handled with due care.  Keep away from direct sunlight.  Avoid impacts, jolts, dust, moisture, and sharp changes of temperature.  Do not use the device at tem peratures higher than 50 o C ...

  • Newcon Optik LRM 1500M - page 20

    16 7. TROUBLESHOOTING The ranging does not work . The display is transparent. Check the charge of the battery. Replace it if it is weak. Black dots are visible on LC D. Liquid Cryst al Display may have sm all black dots, scratc hes and other blemi shes inherited fro m the manufacturi ng process. These flaws are strictly regulated by num ber, area a ...

  • Newcon Optik LRM 1500M - page 21

    17 8. WARRANTY NEWCON warrants this product against defects in m aterial and workmanshi p for one y ear from the date of the ori ginal pur chase. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product pr ove to be defective during this p eriod, pleas e deliver the product securely packaged in i ...

  • Newcon Optik LRM 1500M - page 22

    18 9. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult this manual first. If the problem remains unresolved, c ontact our cust omer supp ort departm ent at (41 6) 663-6963 or toll f ree at 1-877-368-6666. Our operatin g hours are 9am-5pm, M onday - Friday , Eastern St andard Tim e. At no tim e should ...

  • Newcon Optik LRM 1500M - page 23

    19 10. QUALITY CERTIFICATE LRM 1500M LRM 1800S The unit indicated above has passed the quality inspection. Production date Serial number Quality Inspector Purchase date ...

  • Newcon Optik LRM 1500M - page 24

    NEWCON OPTIK  Printed in Canada R1.TS – 02.12 ...

Manufacturer Newcon Optik Category Hunting Equipment

Documents that we receive from a manufacturer of a Newcon Optik LRM 1500M can be divided into several groups. They are, among others:
- Newcon Optik technical drawings
- LRM 1500M manuals
- Newcon Optik product data sheets
- information booklets
- or energy labels Newcon Optik LRM 1500M
All of them are important, but the most important information from the point of view of use of the device are in the user manual Newcon Optik LRM 1500M.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Newcon Optik LRM 1500M, service manual, brief instructions and user manuals Newcon Optik LRM 1500M. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Newcon Optik LRM 1500M.

A complete manual for the device Newcon Optik LRM 1500M, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Newcon Optik LRM 1500M by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Newcon Optik LRM 1500M.

A complete Newcon Optik manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Newcon Optik LRM 1500M - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Newcon Optik LRM 1500M, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Newcon Optik LRM 1500M, that we can find in the current document
3. Tips how to use the basic functions of the device Newcon Optik LRM 1500M - which should help us in our first steps of using Newcon Optik LRM 1500M
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Newcon Optik LRM 1500M
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Newcon Optik LRM 1500M in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Newcon Optik LRM 1500M?

Use the form below

If you did not solve your problem by using a manual Newcon Optik LRM 1500M, ask a question using the form below. If a user had a similar problem with Newcon Optik LRM 1500M it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)