Manual Alto 52C3KSA -1

24 pages 1.45 mb
Download

Go to site of 24

Summary
  • Alto 52C3KSA -1 - page 1

    1 52C3KSA -1 52C3KSA -2 Operator’ s manual US A IMPORTANT: For your own safety and that of others, please make certain that everyone who uses the 52C3KSA-1/-2 high pressure washer reads and understands these instructions thoroughly prior to operation. ...

  • Alto 52C3KSA -1 - page 2

    2                        C3KSA-1 C3KSA-2       ...

  • Alto 52C3KSA -1 - page 3

    3 IMPORTANT: Read this instruction manual before you start up your high pressure washer for the first time. This machine is a high pressure washer produc- ing a water jet under high pressure which is why severe injuries can occur if the safety precautions are not observed. Therefore a complete understanding of the contents of this instruction manua ...

  • Alto 52C3KSA -1 - page 4

    4 1. 1 Model tag This ALTO high pressure washing system has the serial designation C3KSA. The system is available with one and two pumps respectively. The designation appears from the text on the cabinet, ALTO 52C3KSA- 2 as an example, and the model tag (pos. 9) on the right side of the machine. The tag provides the following details: 1.0 Survey of ...

  • Alto 52C3KSA -1 - page 5

    5 2.0 Instructions for use Safety precautions and warnings US Before starting your high pressure washer for the first time, we advise you to read through the following sections: 2.0 Instructions for use and 3.0 Operating instructions and to follow all instructions to ensure the protection of user, surroundings and machine. - WARNING - Risk of Injec ...

  • Alto 52C3KSA -1 - page 6

    6 Safety precautions and warnings US z For safety reasons only use original ALTO accessories and spare parts. Otherwise the machine could be damaged. z In freezing conditions, never start the machine until it, and the hoses and accessories have thawed. z The machine should not be covered during operation. z The most efficient cleaning is obtained i ...

  • Alto 52C3KSA -1 - page 7

    7 Safety precautions and warnings US z When using detergents, the instructions should always be strictly observed. z Always unplug the machine before cleaning or maintenance of the machine. z Don’t use the machine if the power cord or important parts of the equipment are damaged - i.e. safety devices, high pressure hoses, spray handles, cabinet. ...

  • Alto 52C3KSA -1 - page 8

    8 3.0 Installation US 3. 1 Water connection Flexible hose connection Max. water pressure 218 psi Max. 160°F Inlet water shutoff cock required Clean water inlet screen (1) at monthly intervals The water connection is made through a flexible hose connected to the quick coupling on the water inlet (1) of the machine. The connection can be made to a c ...

  • Alto 52C3KSA -1 - page 9

    9 O Start 1 Installation US 3.4 Venting KSA-1 Turn to position „Start“ Activate spray handle/open outlet point In the case of newly installed systems, or if the pipeline and the pump have been drained in any other way, the system should be vented by starting the pump and then let the water run freely at each outlet point of the pipeline in turn ...

  • Alto 52C3KSA -1 - page 10

    10 4.0 Operating instructions US 4.1 Connections 1. High pressure hose - directly on the machine Max. length of extension hose: 160 ft. Only use ALTO high pressure hose Danger of scalding! Never dismount high pressure hoses at water temperatures above 120°F The high pressure hose with imprinted max. working pressure and temperature should be attac ...

  • Alto 52C3KSA -1 - page 11

    11 Operating instructions US 4. Detergents If you want to apply detergents or disinfectants these can be metered through an accessory injector. Below you will find various types of outlet points with injectors. Outlet point with detachable injector To be attached to the quick coupling of the high pressure cock. To be used for dosing of low-foaming ...

  • Alto 52C3KSA -1 - page 12

    12 C3KSA-2 2 1+2 O 1    Operating instructions US 4. 2 Starting Check that the oil level in the oil reservoir(s) (2) is between the MIN. and MAX. markings. The inlet water shut-off cock should be open. NOTE: The system automatically stops after approx. 4 seconds if there is no water consumption. In the event of a power failure or activatio ...

  • Alto 52C3KSA -1 - page 13

    13 Operating instructions US 4. 4 Double spray lance, regulation of pressure and water volume - KSA-1 Turn spray lance pressure reducing valve (1): Clockwise (B): high pressure Counter clockwise (A): low pressure/ detergent application The spray lance employs a high pressure nozzle and a low pressure nozzle. On KSA-1 pump systems the water volume i ...

  • Alto 52C3KSA -1 - page 14

    14 Operating instructions US 4. 6 End of operation Turn to position 0 Never detach the high pressue hose while the machine is in operation = Position 1, 2 or 1+2. Danger of scalding! Never detach high pressure hoses at a water temperature above 120°F To stop the machine turn the red start/stop knob (1) to position 0. Close the shut-off cock of the ...

  • Alto 52C3KSA -1 - page 15

    15 5.0 Applications and working methods US 5. 1 Fields of application The most important fields of application for this product are: Agriculture Cleaning machinery, agricultural implements, stalls, equipment, and buildings Transport Cleaning trucks, buses, cars etc. Building and construction Cleaning vehicles, equipment, buildings etc. Light indust ...

  • Alto 52C3KSA -1 - page 16

    16 Applications and working methods US General rules for addition of detergents ALTO cleaning equipment can be used for all detergents and disinfectants, which are suitable for high pressure cleaning according to the supplier. (The pH-value should be between 4 and 14). Acid and lye should not be applied in a concentrated form. Carefully observe the ...

  • Alto 52C3KSA -1 - page 17

    17 6.0 Maintenance US A minimum of maintenance ensures prolonged and problem-free operation. It’s a good idea to make a habit of the following: Prior to attaching the water hose and the high pressure hose, the quick couplings should be rinsed to remove dirt. Prior to attaching the spray lance or other accessories to the spray handle, the machine ...

  • Alto 52C3KSA -1 - page 18

    18 7.0 Troubleshooting and correction US You have chosen the best quality and therefore deserve the best service. To avoid unnecessary disap- pointments, you should check the following before contacting the nearest ALTO service organisation: Fault Cause Correction Machine will not start A fuse has blown Change the fuse Power/plug not connected Conn ...

  • Alto 52C3KSA -1 - page 19

    19 ...

  • Alto 52C3KSA -1 - page 20

    ...

  • Alto 52C3KSA -1 - page 21

    ...

  • Alto 52C3KSA -1 - page 22

    22 ...

  • Alto 52C3KSA -1 - page 23

    23 ...

  • Alto 52C3KSA -1 - page 24

    24 630 79 67 (00.10) Printed in Denmark Copyright © 2000-2001 ALTO Danmark A/S ALTO Danmark A/S Industrikvarteret DK-9560 Hadsund Tel.: +45 7218 2100 www.alto-online.com ...

Manufacturer Alto Category Pressure Washer

Documents that we receive from a manufacturer of a Alto 52C3KSA -1 can be divided into several groups. They are, among others:
- Alto technical drawings
- 52C3KSA -1 manuals
- Alto product data sheets
- information booklets
- or energy labels Alto 52C3KSA -1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Alto 52C3KSA -1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Alto 52C3KSA -1, service manual, brief instructions and user manuals Alto 52C3KSA -1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Alto 52C3KSA -1.

A complete manual for the device Alto 52C3KSA -1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Alto 52C3KSA -1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Alto 52C3KSA -1.

A complete Alto manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Alto 52C3KSA -1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Alto 52C3KSA -1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Alto 52C3KSA -1, that we can find in the current document
3. Tips how to use the basic functions of the device Alto 52C3KSA -1 - which should help us in our first steps of using Alto 52C3KSA -1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Alto 52C3KSA -1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Alto 52C3KSA -1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Alto 52C3KSA -1?

Use the form below

If you did not solve your problem by using a manual Alto 52C3KSA -1, ask a question using the form below. If a user had a similar problem with Alto 52C3KSA -1 it is likely that he will want to share the way to solve it.

Copy the text from the picture