    246819-BTG-H-0208 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT - SYSTEM HEA T PUMPS 13 SEER – R-22 MODELS: E*BD-F018 THRU 060 (1.5 THRU 5 NOMINAL T ONS, 1 PHASE) E*BD-(T ,W)036 THRU 060 (2.5 THRU 5 NOMINAL T ONS, 3 PHASE) Due to continuo us product imp rovement, speci fications are subject to chan ge without notice. Vi ...

  • York E*BD-F018 THRU 060 - page 2

    246819-BTG-H-0208 2 Unitary Products Group All dimensions are in inches. They are subject to cha nge without notice. Ce rtif ied dimensio ns will be provide d upon request. Physical and Electrical Dat a - 1 Phase MODEL EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Unit Supply V oltage 208-230V , 1 φ, 60Hz Normal V ol ...

  • York E*BD-F018 THRU 060 - page 3

    246819-BTG-H-0208 Unitary Products Group 3 Additional R-22 Charge / Orifice Size for V arious Matched Syste ms - 1 Phase Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EAB D-F036S EABD-F042S EABD-F048S EABD-F060S Required TXV 1 TVM2A1 1 TVM2A1 1 TVM2A1 1 TVM2A1 1 TVM2C1 1 TVM2C1 1 TVM2C1 Factory Charge, lbs-oz 7 - 1 6 - 9 8 - 9 8 - 7 8 - 7 12 - 8 16 ...

  • York E*BD-F018 THRU 060 - page 4

    246819-BTG-H-0208 4 Unitary Products Group * This loose coil match does not achieve 13 SEER. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes re frigerant for the condenser , the smallest evaporator and 15 feet of inter- connecting line tubing. 2. V erify the orifice size and the additional charge required for t he specific ...

  • York E*BD-F018 THRU 060 - page 5

    246819-BTG-H-0208 Unitary Products Group 5 All dimensions are in inche s. Th ey are su bject to change with- out notice. Certified dimensions will be pro vided upon request. Physical and Elect rical Dat a - 3 Ph ase MODEL EABD- T030S EABD- T036S EABD- T042S EABD- T048S EABD- T060S EABD- W030S EABD- W036S EABD- W042S EABD- W048S EABD- W060S Unit Sup ...

  • York E*BD-F018 THRU 060 - page 6

    246819-BTG-H-0208 6 Unitary Products Group PROCEDURES: 1. U nit factory charge listed on the unit nameplate includes refr igerant for the condenser , the smallest evaporator and 15 feet of inter-con- necting line tubing. 2. Verify the TXV and additional charge required for specific evaporator coil in the system using th e above table. 3. Additional ...

  • York E*BD-F018 THRU 060 - page 7

    246819-BTG-H-0208 Unitary Products Group 7 COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 & 3 PH 13 SEER HP WITH MA EABD-F018S MA08B 17 FC/MC18B 600 18 .0 12.4 13 .00 1 1.00 EABD-F024S MA08B 17 FC/MC24B 800 23.2 16.8 13.00 1 1.00 MA08B 17 FC/MC30B 800 23 ...

  • York E*BD-F018 THRU 060 - page 8

    246819-BTG-H-0208 8 Unitary Products Group — = Not Applicable. Go to www.ari. org/aridirectory for the latest additiona l matches. 1 PH 13 SEER AC WITH A V / SV - V ARIABLE SPEED EABD-F018S A V24 17 – 600 18.0 12.6 14.00 12.00 EABD-F024S A V24 17 – 800 23.8 16.7 14.00 12.00 EABD-F030S A V36 17 – 1000 29.2 20.1 14 .00 12.00 EABD-F036S A V36 ...

  • York E*BD-F018 THRU 060 - page 9

    246819-BTG-H-0208 Unitary Products Group 9 COOLING CAP ACITY - Upflow , Downflow , and Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. EABD-F018S 450 750 14,17 FC/MC/PC/UC18 600 18.0 12 .4 13.00 1 1.00 14 HC18 600 17.8 12 .1 13.00 1 1.00 EABD-F024S 600 1000 14 ...

  • York E*BD-F018 THRU 060 - page 10

    246819-BTG-H-0208 10 Unitary Products Group COOLING CAP ACITY - With V ariable S peed Furnac es UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER HP WITH V ARIABLE SPEED FURNACES 2 EABD-F018S (F ,L)L8V A12 FC/MC/PC18A 14 600 18.0 12.5 14.00 12.00 FL9V A12 FC/MC/PC18A 14 600 18.0 12 ...

  • York E*BD-F018 THRU 060 - page 11

    246819-BTG-H-0208 Unitary Products Group 11 EABD-F048S FL9(C,V)D20 FC/MC/PC60D 24 1600 46.0 35 .5 13.25 1 1.00 (F ,L)L8VC16 FC/PC60C 21 1500 45.5 35.1 13 .25 1 1.00 (F ,L)L8VC20 FC/PC60C 21 1600 46.0 35.4 13 .25 1 1.00 FL9(C,V)C16 FC/PC60C 21 1600 46.0 35 .5 13.25 1 1.00 FL9(C,V)C20 FC/PC60C 21 1600 46.0 34 .5 13.25 1 1.00 FL9(C,V)D20 HC60 24 1600 ...

  • York E*BD-F018 THRU 060 - page 12

    246819-BTG-H-0208 12 Unitary Products Group HEA TING PERFORMANCE - With Air Handler UNIT MODEL* AIR HANDLER COIL 1 MODEL ARI HEA T ING 2 47 ° F1 7 ° FH S P F MBH COP KW MBH COP KW STD 1 & 3 PH 13 SEER HP WITH MA EABD-F018S MA08B FC/MC18B 18.0 3.62 1.46 10.5 2.28 1 .35 8.00 EABD-F024S M A 0 8 B F C / M C 2 4 B 2 3 . 03 . 4 41 . 9 61 3 . 12 . 3 ...

  • York E*BD-F018 THRU 060 - page 13

    246819-BTG-H-0208 Unitary Products Group 13 CP equals MBH output divided by (t otal KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating ou tput during a normal annual usage period for heating divided by the total electric power input during the same period. — = Not Applicable. 1 PH 13 SEER HP WITH A V - V ARIABLE SP ...

  • York E*BD-F018 THRU 060 - page 14

    246819-BTG-H-0208 14 Unitary Products Group CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heat ing output during a normal annual usage period for heating divided by the total electric power input during the same period. — = Not Applicable. HEA TING PERFOR MANCE - Upflow Furnace C ...

  • York E*BD-F018 THRU 060 - page 15

    246819-BTG-H-0208 Unitary Products Group 15 HEA TING CAP ACITY - W ith V ariable Speed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE COIL 1 MODEL ARI HEA T ING 2 47 ° F1 7 ° FH S P F MBH COP KW MBH COP KW STD EABD-F018S (F ,L)L8V A12 FC/MC/PC18A 17.5 3.88 1.32 10 .0 2.42 1.21 8.60 FL9V A12 FC/MC/PC18A 17.6 3.82 1.35 10 .1 2.40 1.23 8.40 FL9(C,V)B12 ...

  • York E*BD-F018 THRU 060 - page 16

    246819-BTG-H-0208 16 Unitary Products Group CP equals MBH output divided by (to tal KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heat ing output during a normal annual usage period for heating divided by the total electric power input during the same period. — = Not Applicable. EABD-F042S ( F , L ) L 8 V C 2 0 F C / ...

  • York E*BD-F018 THRU 060 - page 17

    246819-BTG-H-0208 Unitary Products Group 17 ACCESSORIES Refer to Price Manual for specific model numbers. St art Assist Kit (2SA067*) Blower Time Delay - A vailable to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute a fter cooling thermostat has been satisfied. Hard St art Kit s - Pro ...

  • York E*BD-F018 THRU 060 - page 18

    246819-BTG-H-0208 18 Unitary Products Group Multipliers for determining th e performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York E*BD-F018 THRU 060 - page 19

    246819-BTG-H-0208 Unitary Products Group 19 Multipliers for determining th e performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increase s by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York E*BD-F018 THRU 060 - page 20

    246819-BTG-H-0208 20 Unitary Products Group Multipliers for determining th e performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York E*BD-F018 THRU 060 - page 21

    246819-BTG-H-0208 Unitary Products Group 21 Multipliers for determining th e performance with other indoor sections NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increase s by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree below ...

  • York E*BD-F018 THRU 060 - page 22

    246819-BTG-H-0208 22 Unitary Products Group Multipliers for determining th e performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York E*BD-F018 THRU 060 - page 23

    246819-BTG-H-0208 Unitary Products Group 23 Multipliers for determining th e performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increase s by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York E*BD-F018 THRU 060 - page 24

    246819-BTG-H-0208 24 Unitary Products Group Multipliers for determining th e performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York E*BD-F018 THRU 060 - page 25

    246819-BTG-H-0208 Unitary Products Group 25 Multipliers for determining the performance with other indoor sections . HEA TING PERFORMA NCE DA T A CONDENSING UNIT MODEL NO EABD-F018S EV APORA T OR COIL MODEL NO FC /MC/PC/UC18 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CFM 450 600 750 MBTUH KW C.O.P . MBTUH KW C.O.P . MBTUH K ...

  • York E*BD-F018 THRU 060 - page 26

    246819-BTG-H-0208 26 Unitary Products Group Multipliers for determining the perfo rman ce with other indoor sections. HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO EABD-F024S EV APORA T OR COIL MODEL NO FC /MC/PC/UC24 AIR TEMP . ENTERING OUTDOOR UNIT AIR TEMP . ENTERING INDOOR COIL ID CFM 600 800 1000 MBTUH KW C.O.P . MBTUH KW C.O.P . MBTU H ...

  • York E*BD-F018 THRU 060 - page 27

    246819-BTG-H-0208 Unitary Products Group 27 Multipliers for determining the performance with other indoor sections . * = Single-phase outdoor units only . * = Single-phase outdoor units only . HEA TING PERFORMA NCE DA T A CONDENSING UNIT MODEL NO E ABD-F030S, EABD-(T ,W)030S** EV APORA T OR COIL MODEL NO FC /MC/PC35 AIR TEMP . ENTERING OUTDOOR UNIT ...

  • York E*BD-F018 THRU 060 - page 28

    246819-BTG-H-0208 28 Unitary Products Group Multipliers for determining the perfo rman ce with other indoor sections. * = Single-phase outdoor units only . * = Single-phase outdoor units only . HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E ABD-F036S, EABD-(T ,W)036S** EV APORA T OR COIL MODEL NO FC /MC/PC/UC48 AIR TEMP . ENTERING OUTDOOR U ...

  • York E*BD-F018 THRU 060 - page 29

    246819-BTG-H-0208 Unitary Products Group 29 Multipliers for determining the performance with other indoor sections . * = Single-phase outdoor units only . * = Single-phase outdoor units only . HEA TING PERFORMA NCE DA T A CONDENSING UNIT MODEL NO E ABD-F042S, EABD-(T ,W)042S** EV APORA T OR COIL MODEL NO FC /MC/PC/UC48 AIR TEMP . ENTERING OUTDOOR U ...

  • York E*BD-F018 THRU 060 - page 30

    246819-BTG-H-0208 30 Unitary Products Group Multipliers for determining the perfo rman ce with other indoor sections. * = Single-phase outdoor units only . * = Single-phase outdoor units only . HEA TING PERFORMANCE DA T A CONDENSING UNIT MODEL NO E ABD-F048S, EABD-(T ,W)048S** EV APORA T OR COIL MODEL NO FC /MC/PC/UC60 AIR TEMP . ENTERING OUTDOOR U ...

  • York E*BD-F018 THRU 060 - page 31

    246819-BTG-H-0208 Unitary Products Group 31 Multipliers for determining the performance with other indoor sections . * = Single-phase outdoor units only . * = Single-phase outdoor units only . HEA TING PERFORMA NCE DA T A CONDENSING UNIT MODEL NO E ABD-F060S, EABD-(T ,W)060S** EV APORA T OR COIL MODEL NO FC /MC/PC/UC60 AIR TEMP . ENTERING OUTDOOR U ...

  • York E*BD-F018 THRU 060 - page 32

    Subject to change without notice. Printed in U.S.A. 246819-BTG-H-0208 Copyright © by Unitary Products Group. 2008. Al l rights reserved. Supersedes: 246819-BTG-G-0607 Unitary 5005 Norman Product Y ork OK Group Drive 73069 NOTES ...

Manufacturer York Category Heat Pump

Documents that we receive from a manufacturer of a York E*BD-F018 THRU 060 can be divided into several groups. They are, among others:
- York technical drawings
- E*BD-F018 THRU 060 manuals
- York product data sheets
- information booklets
- or energy labels York E*BD-F018 THRU 060
All of them are important, but the most important information from the point of view of use of the device are in the user manual York E*BD-F018 THRU 060.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York E*BD-F018 THRU 060, service manual, brief instructions and user manuals York E*BD-F018 THRU 060. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York E*BD-F018 THRU 060.

Similar manuals

A complete manual for the device York E*BD-F018 THRU 060, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York E*BD-F018 THRU 060 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York E*BD-F018 THRU 060.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York E*BD-F018 THRU 060 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York E*BD-F018 THRU 060, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York E*BD-F018 THRU 060, that we can find in the current document
3. Tips how to use the basic functions of the device York E*BD-F018 THRU 060 - which should help us in our first steps of using York E*BD-F018 THRU 060
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York E*BD-F018 THRU 060
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York E*BD-F018 THRU 060 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York E*BD-F018 THRU 060?

Use the form below

If you did not solve your problem by using a manual York E*BD-F018 THRU 060, ask a question using the form below. If a user had a similar problem with York E*BD-F018 THRU 060 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)