    Installation Instructions & Owner’ s Manual P/N 520022 January 2005 425 Clair Road W est, P .O. Box 1719 • Guelph, ON • N1H 7X4 • Canada t. 519.763.1032 • f. 519.763.5069 • t.f. 1.800.265.7246 e. water@r -can.com • i. www .r-can.com S12Q, S12Q-GOLD, S24Q, S24Q-GOLD, S40Q EP A # 57987-CN-001 ...

  • Sterilite S12Q - page 2

    T ABLE OF C ONTENTS : Safety Instructions Page 1 Improved Ballast Features Page 1 W ater Chemistry Page 2 Installing Y our Disinfection System Page 2 Operating & Maintenance Instructions Page 3-4 W arning Systems Page 4-5 W arranty Page 5 T roubleshooting Page 6-8 Parts Page 9 Specifications Page 10 S YMBOLS : Caution Protective Ground Electric ...

  • Sterilite S12Q - page 3

    1 S AFETY I NSTRUCTIONS : I MPROVED B ALLAST F EA TURES : W ARNING - to guard against injur y , basic safety precautions should be obser ved, including the following: 1 . R EAD AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. CAUTION - Disconnect power before servicing. 3. DANGER - T o avoid possible electric shock, special care should be taken since water i ...

  • Sterilite S12Q - page 4

    2 I NST ALLING Y OUR D ISINFECTION S YSTEM : • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. • The disinfection system should be connected to a ground fault interrupter . • The disinfection system is i ...

  • Sterilite S12Q - page 5

    3 O PERA TING & M AINTENANCE I NSTRUCTIONS : • Always disconnect power before performing any work on the ultraviolet disinfection system. • Regularly inspect your disinfection system unit to ensure that the UV light is still glowing and that its LED indicator is still glowing green. • Replace the UV lamp annually ( or biennially if season ...

  • Sterilite S12Q - page 6

    4 f) Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal d istance from both ends of the UV chamber . g) W et the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is sufficient). h) Re-tighten all connections, turn on water and check for leaks. I) Re-inst ...

  • Sterilite S12Q - page 7

    5 into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of d isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to swing open. Remove the circuit board cover plate to expose the cir cuit board. Remove the round, black ...

  • Sterilite S12Q - page 8

    6 TROUBLESHOOTING GUIDE Caution: When performing any work on the disinfection system unplug the unit first and never look directly at the b urning UV lamp. SYMPTOM POSSIBLE CAUSES REMEDY PRESSURE DROP • the sediment pre-filter is clogged • replace filter cartridge with appropriate five micron cartridge, Note: check source water supply as fluctu ...

  • Sterilite S12Q - page 9

    7 S12Q TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS LAMP ST A TUS (GREEN LED) AUDIBLE ALARM UV LAMP ON OFF ON • Correct operating conditions, unit is functioning properly . OFF ON OFF • The UV lamp is spent, requires replacement lamp. • UV lamp not connected to power source. Check connection and reconnect lamp. • Ballast has switched off. ...

  • Sterilite S12Q - page 10

    8 S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS UV INTENSITY (LED) AUDIBLE ALARM UV LAMP GREEN OFF ON • Correct operating conditions unit is functioning properly . YELLOW OFF ON • System performance has declined due to stained or dirty quartz sleeve and or sensor lens, or the lamp is beyond its useful life. • Clean s ...

  • Sterilite S12Q - page 11

    9 S12Q P ARTS BREAKDOWN S 36RL UV LAMP Q S-012 QUARTZ SLEEVE OR-212 O RING BA-ICE-3F BALLAST (100-130V/50-60Hz. or 200-250V/50-60Hz.) S UB-WH/LED512 LED INDICA TOR ASSEMBL Y RN-001 RET AINING NUT CS-001/Q CORD SET (120V .) CS-EU/Q EUROPEAN “SCHUKO” CORD SET (230V .) DP750 RET AINING NUT PLUG SP-3/8 3/8” DRAIN PLUG SP008 QUARTZ SLEEVE SPRING S ...

  • Sterilite S12Q - page 12

    10 SPECIFICA TIONS MODEL S12Q S12Q-GOLD S24Q S24Q-GOLD S40Q US Public Health 16 mJ/cm 2 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 3 67.2 lpm (97 gpm) ( 22.0 m 3 / Hr .) R-Can Standard 30 mJ/cm 2 56.8 lpm (15 gpm) (3.4 m 3 /Hr .) 56.8 lpm ...

Manufacturer Sterilite Category Baby Accessories

Documents that we receive from a manufacturer of a Sterilite S12Q can be divided into several groups. They are, among others:
- Sterilite technical drawings
- S12Q manuals
- Sterilite product data sheets
- information booklets
- or energy labels Sterilite S12Q
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sterilite S12Q.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sterilite S12Q, service manual, brief instructions and user manuals Sterilite S12Q. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sterilite S12Q.

A complete manual for the device Sterilite S12Q, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sterilite S12Q by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sterilite S12Q.

A complete Sterilite manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sterilite S12Q - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sterilite S12Q, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sterilite S12Q, that we can find in the current document
3. Tips how to use the basic functions of the device Sterilite S12Q - which should help us in our first steps of using Sterilite S12Q
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sterilite S12Q
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sterilite S12Q in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sterilite S12Q?

Use the form below

If you did not solve your problem by using a manual Sterilite S12Q, ask a question using the form below. If a user had a similar problem with Sterilite S12Q it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)