    Installation Instructions & Owner’ s Manual P/N 520022 January 2005 425 Clair Road W est, P .O. Box 1719 • Guelph, ON • N1H 7X4 • Canada t. 519.763.1032 • f. 519.763.5069 • t.f. 1.800.265.7246 e. water@r -can.com • i. www .r-can.com S12Q, S12Q-GOLD, S24Q, S24Q-GOLD, S40Q EP A # 57987-CN-001 ...

  • Sterilite S12Q - page 2

    T ABLE OF C ONTENTS : Safety Instructions Page 1 Improved Ballast Features Page 1 W ater Chemistry Page 2 Installing Y our Disinfection System Page 2 Operating & Maintenance Instructions Page 3-4 W arning Systems Page 4-5 W arranty Page 5 T roubleshooting Page 6-8 Parts Page 9 Specifications Page 10 S YMBOLS : Caution Protective Ground Electric ...

  • Sterilite S12Q - page 3

    1 S AFETY I NSTRUCTIONS : I MPROVED B ALLAST F EA TURES : W ARNING - to guard against injur y , basic safety precautions should be obser ved, including the following: 1 . R EAD AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. CAUTION - Disconnect power before servicing. 3. DANGER - T o avoid possible electric shock, special care should be taken since water i ...

  • Sterilite S12Q - page 4

    2 I NST ALLING Y OUR D ISINFECTION S YSTEM : • The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. • The disinfection system should be connected to a ground fault interrupter . • The disinfection system is i ...

  • Sterilite S12Q - page 5

    3 O PERA TING & M AINTENANCE I NSTRUCTIONS : • Always disconnect power before performing any work on the ultraviolet disinfection system. • Regularly inspect your disinfection system unit to ensure that the UV light is still glowing and that its LED indicator is still glowing green. • Replace the UV lamp annually ( or biennially if season ...

  • Sterilite S12Q - page 6

    4 f) Re-assemble the quartz sleeve with spring in the UV chamber allowing the sleeve to protrude an equal d istance from both ends of the UV chamber . g) W et the o-rings and slide onto each end of the quartz sleeve and reassemble the gland nuts (hand tight is sufficient). h) Re-tighten all connections, turn on water and check for leaks. I) Re-inst ...

  • Sterilite S12Q - page 7

    5 into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of d isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to swing open. Remove the circuit board cover plate to expose the cir cuit board. Remove the round, black ...

  • Sterilite S12Q - page 8

    6 TROUBLESHOOTING GUIDE Caution: When performing any work on the disinfection system unplug the unit first and never look directly at the b urning UV lamp. SYMPTOM POSSIBLE CAUSES REMEDY PRESSURE DROP • the sediment pre-filter is clogged • replace filter cartridge with appropriate five micron cartridge, Note: check source water supply as fluctu ...

  • Sterilite S12Q - page 9

    7 S12Q TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS LAMP ST A TUS (GREEN LED) AUDIBLE ALARM UV LAMP ON OFF ON • Correct operating conditions, unit is functioning properly . OFF ON OFF • The UV lamp is spent, requires replacement lamp. • UV lamp not connected to power source. Check connection and reconnect lamp. • Ballast has switched off. ...

  • Sterilite S12Q - page 10

    8 S12Q-GOLD & S24Q-GOLD TROUBLESHOOTING GUIDE SYSTEM ST A TUS REMARKS UV INTENSITY (LED) AUDIBLE ALARM UV LAMP GREEN OFF ON • Correct operating conditions unit is functioning properly . YELLOW OFF ON • System performance has declined due to stained or dirty quartz sleeve and or sensor lens, or the lamp is beyond its useful life. • Clean s ...

  • Sterilite S12Q - page 11

    9 S12Q P ARTS BREAKDOWN S 36RL UV LAMP Q S-012 QUARTZ SLEEVE OR-212 O RING BA-ICE-3F BALLAST (100-130V/50-60Hz. or 200-250V/50-60Hz.) S UB-WH/LED512 LED INDICA TOR ASSEMBL Y RN-001 RET AINING NUT CS-001/Q CORD SET (120V .) CS-EU/Q EUROPEAN “SCHUKO” CORD SET (230V .) DP750 RET AINING NUT PLUG SP-3/8 3/8” DRAIN PLUG SP008 QUARTZ SLEEVE SPRING S ...

  • Sterilite S12Q - page 12

    10 SPECIFICA TIONS MODEL S12Q S12Q-GOLD S24Q S24Q-GOLD S40Q US Public Health 16 mJ/cm 2 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 1 09.8 lpm (29 gpm) ( 6.6 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 2 19.6 lpm (58 gpm) ( 13.2 m 3 / Hr .) 3 67.2 lpm (97 gpm) ( 22.0 m 3 / Hr .) R-Can Standard 30 mJ/cm 2 56.8 lpm (15 gpm) (3.4 m 3 /Hr .) 56.8 lpm ...

Производитель Sterilite Категория Baby Accessories

Документы, которые мы получаем от производителя устройства Sterilite S12Q мы можем разделить на несколько групп. Это в частности:
- технические чертежи Sterilite
- инструкции обслуживания S12Q
- паспорта изделия Sterilite
- информационные брошюры
- энергетические этикетки Sterilite S12Q
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Sterilite S12Q.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Sterilite S12Q, инструкции обслуживания, короткие инструкции или инструкции пользователя Sterilite S12Q. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Sterilite S12Q.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Sterilite S12Q, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Sterilite S12Q пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Sterilite S12Q.

Полная инструкция обслуживания Sterilite, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Sterilite S12Q - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Sterilite S12Q, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Sterilite S12Q, которое найдем в данном документе
3. Советы по использованию основных функций устройства Sterilite S12Q - которые должны облегчить нам первые шаги во время использования Sterilite S12Q
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Sterilite S12Q
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Sterilite S12Q в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Sterilite S12Q?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Sterilite S12Q, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Sterilite S12Q со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)