Manual EMC 4K VA 20K VA UPS

23 pages 1.29 mb
Download

Go to site of 23

Summary
  • EMC 4K VA 20K VA UPS - page 1

    4K VA – 20K VA UPS ■ User’s and Installation Manual ■ I EMC St atement s CISPR 22 NOTICE: Pursuant to CISPR 22 rules, this product has been tested and thereby complies with the conditions of a Class A digital d e vi ce, which have been established for offer ing sufficient protection ag ainst dangerous interference for installation in a resi ...

  • EMC 4K VA 20K VA UPS - page 2

    II CONTENTS 1. Introduction ...........................................................................................1 2. System desc ription............................................................................... 1 2.1 General de scription......................................................................................1 2.2 System co ...

  • EMC 4K VA 20K VA UPS - page 3

    IV The instructions contained with in this saf e ty manual are d eemed important and should be closely followed at all times during installa tion and follow-up maintenance of the UPS and batteries. CAUTION The unit has a dangerous amount of voltage . If the UPS indicator is on, the unit’s outlets may have a dangerous amount of voltage even w hen ...

  • EMC 4K VA 20K VA UPS - page 4

    2 Fig.1. Block diagram Efficiency Optimizer function The Efficiency Optimizer function is a new feature for the UPS adding cost effectiveness, minimizing power loss and r educing power consumption. Altern ating between bypass and on-line modes is achieved autom atically and in accordance with the condi tions of the utility power. On-line mode may b ...

  • EMC 4K VA 20K VA UPS - page 5

    4 3. Safety information Information presented h ere is vital to all p ersonnel and please also read the UPS safet y manual. Storage and Transporta tion Please handle with extreme caution since a hi gh amount of energy is contained with the batteries. Always keep th e unit in position as marked on the packaging and nev er drop the unit. Installation ...

  • EMC 4K VA 20K VA UPS - page 6

    6 5.2 Rear panel vie ws 4K/5KV A (120VDC ) Rear panel 7 6KV A Rear panel (W itho ut ISO) ...

  • EMC 4K VA 20K VA UPS - page 7

    8 6KV A Rear panel (W ith ISO) 9 8K~10KV A Rear panel (W itho ut ISO) ...

  • EMC 4K VA 20K VA UPS - page 8

    10 8K~10 KV A Rear panel (W ith ISO) 11 12KV A Rear p anel (ISO and With ISO) ...

  • EMC 4K VA 20K VA UPS - page 9

    12 15/20 KV A Rear panel (ISO and With ISO) 13 5.3 Connection to mains and loads (4 000 - 20 000 VA) Only qualified specialists or technicians who conform to applicable safety standards may carry out the inst allation of this equipment. The install ation must further comply with all local legislation and regu lations . Follow all installation and s ...

  • EMC 4K VA 20K VA UPS - page 10

    14 figures 2 and 3 for proper installation. Refer to local wiring rules. z Should computer or alarm connect ions be used, use connections according to ch apter 6 of the manual provided with that option. The connections can be referred to on the rear panel. z The insta llation is now c omplete. b*) removable jum per when dual input used 15 Fig. 2 Fi ...

  • EMC 4K VA 20K VA UPS - page 11

    16 5.4 Default settings at the factory On the LCD display you will find severa l of the UPS param e ters to select. Default settings are as follows: Settings Selection Factory default Output Voltage Setting 208/220/230/ 240 Vac 230V (FOR HV series) Input/Bypass Voltage ±10% +10/-15% +15/-20% +10/-15% Input/Frequency ±2% ±5% ±7% ±5% HE Mode Set ...

  • EMC 4K VA 20K VA UPS - page 12

    18 USB port (option) Connecting the UPS to your computer is a ccomplished through the USB port on the back of your computer. USB compliant hardware and operating s ystem will be necessary including installation of a UPS driver. The se rial port cannot be used when using the USB port. The USB cable is standard and can be bought separ a tely . 6.1 EP ...

  • EMC 4K VA 20K VA UPS - page 13

    20 7.3 Control panel functions Operation of the UPS is indicate d on the mon itor panel with five LED indicators and an LCD screen. This display is als o capable of aler ting the user with audible alarms. ON : This green LED is l it when UPS has been turned on. ON-LINE : When the UPS is in normal or stat ic bypass modes, there is voltage at the ...

  • EMC 4K VA 20K VA UPS - page 14

    22 UPS configurations 1. Various settings that have been chosen are shown in the UPS setting display. 2. To enter configuration mode, press the “FUNC” button for one second. The first configuration parameter will be shown on the LC D display. 3. Press the “FUNC” button to scroll through the p arameters. 4. Press the “ENTER” button to se ...

  • EMC 4K VA 20K VA UPS - page 15

    24 **) Note: In order for the UPS and power ma nagement software to operate normally, Manual Bypass should always be set to OFF as the load will no t be protected by the unit when Manual Bypass is ON. This is aimed for operating an ex ternal mainten a nce bypass switch. ***) Note: You should turn UPS off and keep the AC power b e fore you use “Ge ...

  • EMC 4K VA 20K VA UPS - page 16

    26 7.5 Trouble shooting Displayed on LCD Audible Alarm Alarm Descriptio n What Y ou Should Do Output Overload Two Beeps per second The UPS is overloaded (in Line Mode). Your equipment needs more power than the UPS can provide. The UPS operates in bypass. Shut off the least important equipment connected to the UPS. If this solves the overload proble ...

  • EMC 4K VA 20K VA UPS - page 17

    28 9. Technical Specifications For model with 3 Phase in 1 Phase out Tower model (with LCD display) 8K31 10K31 12K31 15K31 20K31 Capacity (VA) 8000VA 10000VA 12000VA 15000VA 20000VA Capacity C apacity ( W) 5600 W 7000W 8400 W 10500W 14000W 208/360V, 220/38 0V, 230/400V, 240/415V(3 Ф 5W ) Load Capacity Voltage/Rang e Load Capacity 208~241V 0~25% 24 ...

  • EMC 4K VA 20K VA UPS - page 18

    30 Net Weight kg (lb) W/O IS OTR 5 0 ( 1 1 0 ) 86.0 (189.2) 80(176) Shipping W eight kg (lb) W /O ISOTR 5 3 ( 1 1 6 . 7 ) 106.0 (233.2) 101.5(2 23.3) Dimensions W x D x H mm (inc h) W/ ISOTR 257 x 590 x 700 (10.1"x23.2"x 27.6") 342 x 690 x 715 (13. 4" x 27. 2" x 28.1") Net Weight kg (lb) W/ IS OTR 123.0 (270.6) 130 (28 ...

  • EMC 4K VA 20K VA UPS - page 19

    32 Communication R S-232 Serial Port and USB Type Sealed, main tenance-free lead acid batteries DC Voltage (V) Battery (Tow er ) TBD TBD 240V / 12V7.2AH x 20 240V / 12V9AH x 20 Typical Recharge Time to 90% Full 4 hours Management Self-test, adj ustable battery transfer poi nts and alarm set tings Battery Protection Cut off without dr aining any cur ...

  • EMC 4K VA 20K VA UPS - page 20

    34 10. VGD RM 6KVA(3U+3U) Mechanical A. VGD 6K RACK-MOUNT(3U+3U) DESIGN : (1) BASIC COMPONENT : INCLUDING 3U-UPS & 3U-BA TT . CABINET FRONT VIEW R E A R V I E W 35 (2) UPS REAR P ANEL COMPONENTS: H. TERMINAL BLOCK I. BREAKER J. EXTERNAL BA TTER Y CONNECTOR K. BYP ASS SWITCH L. SNMP SLOT M. RS232 + EPO N. TVSS O. USB P. REMOTE CONTROL POR T (3) ...

  • EMC 4K VA 20K VA UPS - page 21

    36 (4) FEA TURE of REMOTE CONTROL FUNCTION: a. Remove the original right si de panel and take apart th e control panel unit. Then assemble the blank right side panel. b. Connect the C ontrol panel unit and Remote contr ol port from rear side. 37 c. Running the remote-c ontr ol function. ...

  • EMC 4K VA 20K VA UPS - page 22

    38 B. 5 in 1 FUNCTION BRACKETS on RACK-MOUNT 3U DESIGN: (1) 19” Rack installation: Mount the 3U rack-mount in a 19-inch EIA 310 C standard rack. 19” rack width 39 (2) 23” Rack installation: Change the position of the two mounting br ackets to mount the 3U rack-mount in a 23-inch EIA 310 C standard r ack. (3) T ower installation: a. Move the m ...

  • EMC 4K VA 20K VA UPS - page 23

    40 (4) W all installation: Move the mounting brackets from the front to the side and attach the bracke ts by screws. Then mount th e UPS to the wall as the below pictures shown. (5) Installation with rear Bracket: W e can use bracket to support the rear side of UPS or battery cabinet. ...

Manufacturer EMC Category Power Supply

Documents that we receive from a manufacturer of a EMC 4K VA 20K VA UPS can be divided into several groups. They are, among others:
- EMC technical drawings
- 4K VA 20K VA UPS manuals
- EMC product data sheets
- information booklets
- or energy labels EMC 4K VA 20K VA UPS
All of them are important, but the most important information from the point of view of use of the device are in the user manual EMC 4K VA 20K VA UPS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals EMC 4K VA 20K VA UPS, service manual, brief instructions and user manuals EMC 4K VA 20K VA UPS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product EMC 4K VA 20K VA UPS.

Similar manuals

A complete manual for the device EMC 4K VA 20K VA UPS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use EMC 4K VA 20K VA UPS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of EMC 4K VA 20K VA UPS.

A complete EMC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual EMC 4K VA 20K VA UPS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the EMC 4K VA 20K VA UPS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the EMC 4K VA 20K VA UPS, that we can find in the current document
3. Tips how to use the basic functions of the device EMC 4K VA 20K VA UPS - which should help us in our first steps of using EMC 4K VA 20K VA UPS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with EMC 4K VA 20K VA UPS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of EMC 4K VA 20K VA UPS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning EMC 4K VA 20K VA UPS?

Use the form below

If you did not solve your problem by using a manual EMC 4K VA 20K VA UPS, ask a question using the form below. If a user had a similar problem with EMC 4K VA 20K VA UPS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)