Manual EMC VI-J00

11 pages 0.91 mb
Download

Go to site of 11

Summary
  • EMC VI-J00 - page 1

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 18 of 88 +IN GA TE IN GA TE OUT –IN +OUT +S TRIM –S –OUT C2 C1 C2 C3 C3 C1 = 100 μ F C2 = 4,700 pF C3 = 0.01 μ F Conditions: Light Load = 3 ...

  • EMC VI-J00 - page 2

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 19 of 88 9. EMC Considerations Common-Mode Noise with Common-Mode Choke. There ar e no special precautions that must be exer cised in the design of ...

  • EMC VI-J00 - page 3

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 20 of 88 9. EMC Considerations L1 C4 C1 = 100 μ F C2 a – C2 b = 4,700 pF (Vicor Part # 01000) C3 a – C3 b = 0.01 μ F (Vicor P ar t # 04872) C4 ...

  • EMC VI-J00 - page 4

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 21 of 88 9. EMC Considerations Differential and Common-Mode Filter with More than One Module . No special precautions ar e needed when using two or ...

  • EMC VI-J00 - page 5

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 22 of 88 3 Amp Load 15 Amp Load 30 Amp Load 9. EMC Considerations Differential-Mode Noise Filter . Differ ential-mode conducted noise current is the ...

  • EMC VI-J00 - page 6

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 23 of 88 9. EMC Considerations RADIA TED NOISE Radiated noise may be either electric field or magnetic field. Magnetic radiation is caused by high d ...

  • EMC VI-J00 - page 7

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 24 of 88 C FET C Rectifier I CM C FET C Rectifier C External C Exter nal I CM Primary Secondar y V p V p V p Baseplate I DM Ycaps Ycaps Figure 9–8 ...

  • EMC VI-J00 - page 8

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 25 of 88 9. EMC Considerations No Additional Filter 2% p-p (T ypical) 1% p-p (T ypical) 0.2% p-p (T ypical) Low ESR Output Cap. 1% p-p (T ypical) 0. ...

  • EMC VI-J00 - page 9

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 26 of 88 9. EMC Considerations NOTE : A low ESR capacitor should be used on the output, preferably tantalum. 3 Amp Load 15 Amp Load 30 Amp Load +IN ...

  • EMC VI-J00 - page 10

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 27 of 88 9. EMC Considerations C1 = 100 µF C2 a – C2 b = 4,700 pF (Vicor P ar t # 01000) C3 a – C3 b = 0.01 µF (Vicor P ar t # 04872) C4 = 270 ...

  • EMC VI-J00 - page 11

    Design Guide & Applications Manual For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies vicorpower .com 800-735-6200 Applications Engineering 1- 800-927-9474 Rev . 2.1 Page 28 of 88 9. EMC Considerations RAM / MI-RAM OPERA TION The RAM / MI-RAM attenuates output noise in two ways. First, an LC filter in the RAM / MI-RAM ...

Manufacturer EMC Category Power Supply

Documents that we receive from a manufacturer of a EMC VI-J00 can be divided into several groups. They are, among others:
- EMC technical drawings
- VI-J00 manuals
- EMC product data sheets
- information booklets
- or energy labels EMC VI-J00
All of them are important, but the most important information from the point of view of use of the device are in the user manual EMC VI-J00.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals EMC VI-J00, service manual, brief instructions and user manuals EMC VI-J00. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product EMC VI-J00.

Similar manuals

A complete manual for the device EMC VI-J00, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use EMC VI-J00 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of EMC VI-J00.

A complete EMC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual EMC VI-J00 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the EMC VI-J00, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the EMC VI-J00, that we can find in the current document
3. Tips how to use the basic functions of the device EMC VI-J00 - which should help us in our first steps of using EMC VI-J00
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with EMC VI-J00
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of EMC VI-J00 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning EMC VI-J00?

Use the form below

If you did not solve your problem by using a manual EMC VI-J00, ask a question using the form below. If a user had a similar problem with EMC VI-J00 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)