Manual Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove

42 pages 1.14 mb
Download

Go to site of 42

Summary
  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 1

    Yankee Pellet Stove • Horizontal Or Vertical Vent • Freestanding Stove • Mobile Home Approved • Class A Chimney Retrofit • Hearth Stove into Existing Masonry Chimney , Masonry Fireplace, or Z.C. Fireplace Tested and Listed by Omni-Test Laboratories, Inc. Beaverton, Oregon Report # 028–S–42-2 ASTME-1509 1995, ULCC 1482 - - Please read ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 2

    2 Introduction Travis Industries 4040714 100-01156 Introduction We welcome you as a new owner of a Yankee pellet heater. In purchasing a Yankee you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Yankee is one of the finest home heaters the wo ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 3

    Table of Contents 3 Travis Industries 4050418 100-01156 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ............................................4 Specifications Heating Specifications ......................... ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 4

    4 Safety Precautions Travis Industries 4050418 100-01156 • Do not operate the heater if you smell smoke coming from the heater. Turn the M ODE switch to "OFF", monitor your heater, and call your dealer. Ok • Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirem ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 5

    Table of Contents 5 Travis Industries 4050418 100-01156 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V., 60 Hz grounded electrical outlet. Do not use an adapter plug or ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 6

    6 Specifications Travis Industries 4050418 100-01156 Heating Specifications: Approximate Maximum Heating Capacity (in square feet)* ........................................ 800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)** ............................................................................ 1.7 to 5.5 Maximum Burn Time on Low Burn** ..... ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 7

    Installation (For Qualified Installers Only) 7 Travis Industries 4050418 100-01156 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. Check with local building officials for any permits required for installation of this pell ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 8

    8 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Clearances - Straight Installation 6 ” Minimum 3 ” Minimum 9 ” Minimum 3 ” Minimum Through the Wall Installations Interior Vertical Vents Floor Protection 6 ” Minimum 2 ” Minimum 9 ” Minimum “ Tee ” Clearances - Corner Installation 6 ” Minimum Thr ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 9

    Installation (For Qualified Installers Only) 9 Travis Industries 4050418 100-01156 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTAL ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 10

    10 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Pellet Vent Type • Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc … ) must be sealed with 500 ° F. ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 11

    Installation (For Qualified Installers Only) 11 Travis Industries 4050418 100-01156 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the floor (Some states do not require this; check with your local building department). See the illustration to the right. • The ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 12

    12 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met. • Minimum height i ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 13

    Installation (For Qualified Installers Only) 13 Travis Industries 4050418 100-01156 Installation Example: Direct "Through-the-wall" Installation 3 ” Minimum 9 ” Minimum Floor Protection 6 ” Minimum House Shield (used to protect exterior wall from soot discoloration) is HIGHLY RECOMMENDED 12 ” Minimum Horizontal Rain Cap Wall Thimb ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 14

    14 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Installation Example: Interior Vertical Installation Type "L" Vent 6 ” Minimum 3 ” Minimum Floor Protection 2 ” Minimum 9 ” Minimum “ Tee ” Outside Air (optional) Floor Protection 24 ” Minimum Insulation must maintain 3 ” clearance. Outside ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 15

    Installation (For Qualified Installers Only) 15 Travis Industries 4050418 100-01156 Installation Example: Class A Chimney Retrofit Type "L" Vent 6 ” Minimum 3 ” Minimum Floor Protection 2 ” Minimum 9 ” Minimum “ Tee ” Outside Air (optional) Floor Protection Outside air may be drawn from a ventilated crawl space. 2 ” Min. 3 ? ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 16

    16 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Installation Example: Masonry Fireplace Hearth Stove “ L ” Vent Flex Section Outside air may be drawn from the ash cleanout. 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. NOTE: you ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 17

    Installation (For Qualified Installers Only) 17 Travis Industries 4050418 100-01156 Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove “ L ” Vent Flex Section 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. NOTE: you will probably need a short horizo ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 18

    18 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Installation Example: Freestanding Masonry Chimney “ L ” Vent Sections 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone. Allow room for the hopper lid to open 53-3/8 ” 3 ” Minimum C ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 19

    Operation 19 Travis Industries 4050418 100-01156 Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death. ! Do not unplug the stove to turn it off. This stove relies upon electricity ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 20

    20 Operatio n Travis Industries 4050418 100-01156 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. Make sure pellets are not left on this heat shield. P e t e l s l To Close the Hopper Lid: lift the lid, pull this bar forward, then lower the lid down. To Open the Hopper Lid: lift the hopper lid ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 21

    Operation 21 Travis Industries 4050418 100-01156 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes. During this period the low ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 22

    22 Operation Travis Industries 4050418 100-01156 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected. To Adjust Room Temperature ( ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 23

    Operation 23 Travis Industries 4050418 100-01156 Restrictor Adjustment The exhaust restrictor “ fine tunes ” your appliance, adjusting the amount of air flowing to the flame. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system. Not Enough Air: If clinkers develop or the flame appears lazy and s ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 24

    24 Operation Travis Industries 4050418 100-01156 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.). This sequence over-rides all u ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 25

    Maintenance 25 Travis Industries 4050418 100-01156 Daily Maintenance (whenever using the stove) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system. See "Restrictor Adjustment" ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 26

    26 Maintenance Travis Industries 4050418 100-01156 Daily Maintenance (whenever using the stove) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers. The most likely causes are: • Restrictor needs adjustment (see “ Restrictor Adjustment ” in ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 27

    Maintenance 27 Travis Industries 4050418 100-01156 Door Opening WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before opening the door. When securing the door, make sure the pawl fits over the bracket before tightening. NOTE : Do not overtighten the pawl. This can permanently damage the latch and prematurely wear out the ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 28

    28 Maintenance Travis Industries 4050418 100-01156 Bi-Weekly Maintenance (or every 10 bags of pellets) Clean the Heat Exchange Tubes WARNING: The front edge of the hopper lid becomes very hot, do not touch the area below the handle. With the stove cool (or using the door latch tool), move the heat exchange cleaner up and down several times. Keep th ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 29

    Maintenance 29 Travis Industries 4050418 100-01156 Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued Clean the Baffles Lift the left side baffle up and move it towards the front of the stove. Rotate the back of the baffle forward. b c d e The baffle rests on this ledge at the back of the firebox. Note how this tab inserts into this sl ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 30

    30 Maintenance Travis Industries 4050418 100-01156 Sweep Ash Into Ashpan HINT: The more often you clean out the flyash, the more efficient your heater will burn. Swing the side ash trap door up. Lift it up and away from the firebox. Repeat for the opposite side. Lift the firepot out of its holder. Slide the ash pan trap door forward to expose the a ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 31

    Maintenance 31 Travis Industries 4050418 100-01156 Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued Check Ashpan, Dispose if necessary NOTE : When replacing the ash pan make sure it is pushed all the way in. The ash pan has a built in handle to ease transportation of the ashes. Disposal of Ashes – Ashes should be placed in a metal ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 32

    32 Maintenance Travis Industries 4050418 100-01156 Yearly Maintenance (or every two tons) WARNING: Disconnect the power cord prior to conducting service. The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your dea ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 33

    Maintenance 33 Travis Industries 4050418 100-01156 Yearly Maintenance (or every two tons) - Continued Clean the Exhaust Blower (make sure the stove is cool and unplugged) Restrictor Knob a Open the hopper lid and remove the screw holding the left door in place. Remove the restrictor knob. Swing the left side panel open. Remove the six screws holdin ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 34

    34 Maintenance Travis Industries 4050418 100-01156 Yearly Maintenance (or every two tons) - Continued Door Seal ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction. • The door gasket must contact the entire perimeter of the door and create an ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 35

    Maintenance 35 Travis Industries 4050418 100-01156 Adjusting the Door Hinge and Latch • The door hinge and door latches may be adjusted to pull the door closer to the body. The illustration below details how to adjust these components. NOTE: Make sure to read the section "Door Alignment" on the previous page before adjusting the door. O ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 36

    36 Maintenance Travis Industries 4050418 100-01156 Check for Air Leaks Around the Door, Glass, and Ashpan ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction. • Inspect the door gasket to make sure it is fully attached. Use stove gasket cemen ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 37

    Normal Operating Sounds 37 Travis Industries 4050418 100-01156 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Convection Fan The modern high efficiency fan may produce a low hum, particularly on "HIGH". This sound will change as the FAN setting is changed. Heat Exchanger Tubes You may hear the ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 38

    38 Safety Label Travis Industries 4050418 100-01156 W ARNING - DO NOT REMOVE OR COVER THIS LABEL Listed Pelletized Solid Fuel Burning Appliance Also for Use in Mobile Homes Model: Y ankee PS Serial No: T ested to: ASTM E, 1509, and ULC-C1482-M1990 Room Heater Pellet Burning T ype (UM) 84 HUD Electrical Rating: 1 15V , 60Hz, 3 Amp; Start 3 Amps, Run ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 39

    Limited 7 Year Warranty 39 Travis Industries 4050418 100-01156 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas applianc ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 40

    40 Optional Equipment Travis Industries 4050418 100-01156 Thermostat (Part # 99300650) ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). 1 Attach the thermostat wire to the circuit board (see the illustration to the right). Route the wire through th ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 41

    Optional Equipment 41 Travis Industries 4050418 100-01156 Remote Thermostat • Follow the instructions included with the remote thermostat for installation. Using the Remote Thermostat The remote thermostat has a 1 to 2 minute lag time between the time the thermostat is turned up and the heater turns on. Included with the remote thermostat is a se ...

  • Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - page 42

    42 Index Travis Industries 4050418 100-01156 Adjusting the Fan Speed ......................................2 3 Air Leaks ..........................................................3 6 Alcove Installation Requirements ..........................1 2 Ashpan (Opening and Disposing Ashes) .................3 1 AUGER ON Light ............................... ...

Manufacturer Lopi Category Stove

Documents that we receive from a manufacturer of a Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove can be divided into several groups. They are, among others:
- Lopi technical drawings
- Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove manuals
- Lopi product data sheets
- information booklets
- or energy labels Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove, service manual, brief instructions and user manuals Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove.

Similar manuals

A complete manual for the device Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove.

A complete Lopi manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove, that we can find in the current document
3. Tips how to use the basic functions of the device Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove - which should help us in our first steps of using Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove?

Use the form below

If you did not solve your problem by using a manual Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove, ask a question using the form below. If a user had a similar problem with Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)