Manual York 12

12 pages 0.26 mb
Download

Go to site of 12

Summary
  • York 12 - page 1

    OUTDOOR SPLIT -SYSTEM AIR CONDITIONER MODELS: 10, 1 2, 13 AND 14 SEER 1 PHASE - 1.5 TO 5 T O NS 035-13606-003 Rev. A (202) T ABLE OF CONTENTS GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . 2 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 L ...

  • York 12 - page 2

    035-13606-003 Rev. A (202) 2 Unitary Products Group GENERAL INFORMA TION These outdoor units are designed to be connected to a matching UPG indoor coil with sweat connection lines. The se units are factory charged with refrigerant for a matching indoor coil plus 15 feet of fie ld supplied line. The outside unit is designed to be placed alongside or ...

  • York 12 - page 3

    035-13606-003 Rev. A (202) Unitary Products Group 3 A minimum clearance of 18 inches is required for service at the control panel and compre ssor compartments access. A 10 inch clearance is required for the air inlet to the outdoor coil around the pe rimeter of the uni t. The air discharg e of the unit requires a 60 inch clearance betwe en the top ...

  • York 12 - page 4

    035-13606-003 Rev. A (202) 4 Unitary Products Group INST ALLA TION OUTDOOR U NIT After the site has been select ed, a solid base pad that will not shift or settle should be provided. Th e base pad should not come in contact with the foundat ion or side of the structur e because sound may be tran smitted to the residence. The pad should be located f ...

  • York 12 - page 5

    035-13606-003 Rev. A (202) Unitary Products Group 5 RE-ASSEMBLING , BRAZING AND CLEANING OF JOINT CONNECTIONS Remove the Schrader V alv e cores from the service valves. Remove the plugs from the service valve fiel d tubing connec- tions. Clean the jo ints to be brazed. NOTE: Do not overheat the connection to be brazed as this can cause improper flo ...

  • York 12 - page 6

    035-13606-003 Rev. A (202) 6 Unitary Products Group REFRIGERANT V AL VE OPERA TION All models in this series have brass service va lves. These valves are not back seating. Opening or closing valve does not close service port. Service ports have Schrader valves for gauge connections. Use back-up wre nch on valve body when removing cap to open o r cl ...

  • York 12 - page 7

    035-13606-003 Rev. A (202) Unitary Products Group 7 LOW VOL T AGE Control wiring may vary depending upon the type of thermo- stat and furnace being connected. Low voltage wiring diagrams can be found with the furnace or air conditioning blower package installation instructions. Pig-tail connector wires (2 blue or 1 blue, 1 brown) are pro- vided fro ...

  • York 12 - page 8

    035-13606-003 Rev. A (202) 8 Unitary Products Group E SYSTEM CHARGE The factory charge in the outdoor unit includes enough charge for the unit a nd a most sold matched evaporator . Some indoor coil matches may requi re some additional charge. See T abular Data sheet provided in unit literature packet. Sweat connect units also include sufficient cha ...

  • York 12 - page 9

    035-13606-003 Rev. A (202) Unitary Products Group 9 T able 3: SUPERHEA T V ALUE INDOOR WB ° F 1 OUTDOOR DB ° F 55 60 65 70 75 80 85 90 95 100 105 1 10 1 15 50 9 7 52 12 10 6 54 14 12 10 7 56 17 15 14 10 6 58 20 18 16 13 9 5 60 23 21 19 16 12 8 6 62 26 24 22 19 16 12 8 5 64 29 27 24 21 18 15 1 1 9 6 66 32 31 30 24 23 18 15 1 1 9 6 68 35 33 30 27 2 ...

  • York 12 - page 10

    035-13606-003 Rev. A (202) 10 Unitary Products Group 3. Measure and record the suction pressure at the su ction service valve port. 4. Using T a ble 4, note the superheat value corresponding to the intersecti on of the indoor wet b ulb and the outdoor dry bulb. 5. With the superheat value o btained in step 4 and the suc- tion pressure value from st ...

  • York 12 - page 11

    035-13606-003 Rev. A (202) Unitary Products Group 11 SER VICE RECORDS ...

  • York 12 - page 12

    Subject to change without notice. Printe d in U.S.A. 035-13606-003 Rev. A (202) Copyright © by Y ork International Corp. 2002. All rights reserved. Supersedes: 035-13606-002, 550.46-N1Y (199) Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

Manufacturer York Category Air Conditioner

Documents that we receive from a manufacturer of a York 12 can be divided into several groups. They are, among others:
- York technical drawings
- 12 manuals
- York product data sheets
- information booklets
- or energy labels York 12
All of them are important, but the most important information from the point of view of use of the device are in the user manual York 12.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals York 12, service manual, brief instructions and user manuals York 12. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product York 12.

Similar manuals

A complete manual for the device York 12, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use York 12 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of York 12.

A complete York manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual York 12 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the York 12, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the York 12, that we can find in the current document
3. Tips how to use the basic functions of the device York 12 - which should help us in our first steps of using York 12
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with York 12
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of York 12 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning York 12?

Use the form below

If you did not solve your problem by using a manual York 12, ask a question using the form below. If a user had a similar problem with York 12 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)