Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 1
GPC 14 SEER R-410A Package Air Conditioners with R-410A Copyright © 2009 - 2010 Goodman Manufacturing Company, L.P. RT6322007r6 September 2010 **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 2
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 3
PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPC1424H41AA GPC1430H41AA GPC1436H41AA GPC1442H41AA GPC1448H41AA GPC1460H41AA The United States Environmental Protection Agency (“EPA”) ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 4
4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions. The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended. A return air filter must be inst ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 5
PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- vice person with rails or guards i ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 6
6 PRODUCT DIMENSIONS GPC14[24-60]H41A* Ch ass i s M o d el A B GPC 142 4 33 3 0½ GPC 143 0 33 3 0½ GPC 143 6 33 3 5½ GPC 144 2 33 3 5½ GPC 144 8 33 3 8½ GPC 146 0 33 3 8½ Dime n s ion s in i n c he s La rge Sm a l l Me d i u m 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T OPEN I NGS) A 14 . 0 00 B ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 7
PRODUCT DESIGN 7 HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection du ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 8
ACCESSORIES 8 GPC14[24-60]H41A* P ar t N u mb er D esc ri p t i o n O T 18- 60 A O utdoor T her mos ta t Ki t w /Loc ko ut S tat O T /E HR 18 - 60 E me r gen c y Heat Relay Ki t HK R E l ec tr i c Heat K i t P CCP1 01 -103 Roof Cur b P C P101 - 103 Downflow P l enum K i t P C P101 - 103R8 Downfl ow P l enum K i t w / R - 8 Ins ul ation G PCE D1 01- ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 9
BLOWER PERFORMANCE DA T A 9 Dry Coil Data GPC14[24-60]H41A* 0. 1 0 .2 0 .3 0 .4 0 .5 0 .6 0 . 7 0 . 8 C F M 9 34 75 9 75 5 63 8 58 1 4 8 9 - - W A T T S 9 57 77 67 38 39 0 - - C F M 9 90 83 7 80 1 74 4 69 6 6 5 2 6 0 1 - W ATT S 1 07 9 4 10 5 11 0 1 1 9 1 3 3 14 2 - C F M 106 1 9 89 9 47 9 25 8 76 - - - W ATT S 1 26 1 3 4 14 6 15 8 16 9 - - - C F M ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 10
10 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 11 0 1 2 0 100 13 0 14 0 15 0 100 90 80 70 60 50 40 30 20 10 OUT P UT B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C F M FORMULA S BTU OUTPUT = CFM x 1.08 x RISE RISE = BTU OUTPUT 1.0 8 ÷ CF M 800 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 11
P ACKAGE COOLING SPECIFICA TIONS 11 GPC14[24-30]H41AA IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection D ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 12
P ACKAGE COOLING SPECIFICA TIONS 12 GPC14[36-42]H41AA IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection D ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 13
P ACKAGE COOLING SPECIFICA TIONS 13 IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection Device: MUST use Ti ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 14
14 COOLING PERFORMANCE DA T A GPC1424H41AA MOD E L : G P C 1424H41A * EX PAN DE D P ER FO R MANC E D ATA C OOL I NG OP E R AT I ON De s ign Sub c ooli ng , 9 ± 2°F @ the l i qui d a c c e s s fitting c onn e ct i on A HRI 9 5 te s t c ondi t io ns . Desi gn S upe r he at 5 ± 2 °F @ the c om pr es sor s uct i o n a cce ss fi tti n g co n nect io ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 15
15 COOLING PERFORMANCE DA T A GPC1424H41AA MOD E L : G PC 1424H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 9 ± 2°F @ the l i qui d acce s s f i tting c onn e ct i on A HRI 9 5 te s t c ondi t i ons . De s i gn S upe r he at 5 ± 2 °F @ the c om pr es sor s u cti on a cce ss fi t ti ng co n nect ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 16
16 COOLING PERFORMANCE DA T A GPC1430H41AA MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn S ubc ooli ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onnec tion A RI 9 5 test c ondi tio ns . De s i g n S up e rh e at 1 0 ± 2 °F @ the c o m p r es sor sucti o n acc ess f itt i n g co n n e ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 17
17 COOLING PERFORMANCE DA T A GPC1430H41AA MOD E L : G PC 1430H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s ign S ubc ool i ng , 1 0 ± 2 °F @ the l i qui d a c ce s s f i tting c onne ct i on A R I 9 5 t e st conditio ns . De s i g n Sup e rh e at 1 0 ± 2 °F @ the c o m p r es so r suct i o n acc ess f itt i n g c ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 18
18 COOLING PERFORMANCE DA T A GPC1436H41AA MOD E L : G P C 1436H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st c onditi ons. De s i gn S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n . ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 19
19 COOLING PERFORMANCE DA T A GPC1436H41AA MOD E L : G PC 1436H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ t he l iqui d a cc e ss fitting con ne c t i on A RI 95 te st cond i tions. De sign S uperhe at 9 ± 2 °F @ t he c omp r e ssor su cti o n acc ess f it ti n g co n n e cti o n ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 20
20 COOLING PERFORMANCE DA T A GPC1442H41AA MOD E L : G P C 1442H 41A * EX PAN DE D P ER FO R M ANC E D AT A C OOLI NG OP E R ATION Desi g n Su b co o l i n g , 8 ± 2 ° F @ th e l i q u i d acc ess f it ti ng co n n e cti o n A H R I 9 5 test c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m p re sso r su ct io n ac ces s fi t ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 21
21 COOLING PERFORMANCE DA T A GPC1442H41AA MOD E L : G PC 1442H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON Desi g n Su b co o l i n g, 8 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e ct i o n A HR I 9 5 t est c o n d i t i o n s. D esi g n Su p er h ea t 8 ± 2 ° F @ t h e co m pr e s s or suc t i on acce s s f ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 22
22 COOLING PERFORMANCE DA T A GPC1448H41AA MOD E L : G P C 1448H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d a c ce s s f i tting c onne c tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he at 1 0 ± 2 °F @ t he c ompr e ss or suc tion ac c es s fi t ti n g c onne c t ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 23
23 COOLING PERFORMANCE DA T A GPC1448H41AA MOD E L : G PC 1448H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 10 ± 2 °F @ the l i qui d acce s s f i tting c onnec tion A HRI 95 te s t c ondi ti ons . Desi gn S u pe r he a t 10 ± 2 ° F @ t he c o mpr e ss or suc tion a c c e s s fi t tin g c onne ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 24
24 COOLING PERFORMANCE DA T A GPC1460H41AA MOD E L : G P C 1460H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON Desi g n Su b co o l i n g, 6 ± 2 ° F @ th e l iqu i d acc ess f it ti n g co n n e cti o n A H R I 9 5 t est c on d i t i o n s. D esi g n Su p er h ea t 9 ± 2° F @ th e co m p re s s or s uct io n a cc e s s fit t ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 25
25 COOLING PERFORMANCE DA T A GPC1460H41AA MOD E L : G PC 1460H41A * EX PA N DE D P ER F O R M AN C E D AT A C OOL I NG OP ER AT I ON De s i gn Sub cooli ng , 6 ± 2 °F @ the l i quid ac c es s fi t t i n g co nne c tion AH RI 9 5 t e s t c ond iti ons. De sign S upe r hea t 9 ± 2 °F @ the c ompre s s or sucti o n a c ce s s f itting c onne c ti ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 26
26 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 27
WIRING DIAGRAMS 27 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE POWE R S OUR CES MAY B E PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC14[24-60]H41AA ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 28
28 GPC 14 SEER R-410A 5mm Package Air Conditioners GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions. The connecting ductwork (Supply and Return) can be con- nected for either horizontal or vertical airflow. In the vertical application a matching Roof Curb is recommended ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 29
PRODUCT DESIGN 29 Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. 36" 36" 10" UNIT WALL 36" Outside Slab Installation - Horizontal (H) Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. 36" 36" 24&quo ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 30
P ACKAGE COOLING SPECIFICA TIONS 30 IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection Device: MUST use Ti ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 31
P ACKAGE COOLING SPECIFICA TIONS 31 IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters. (1) Maximum Overcurrent Protection Device: MUST use Ti ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 32
32 COOLING PERFORMANCE DA T A GPC1424H41AB 5MM COILS MOD E L : G P C 1424H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t eri n g In d o o r W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 7 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 33
33 COOLING PERFORMANCE DA T A GPC1424H41AB 5MM COILS MOD E L : G P C 1424H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOL ING OP E R AT ION O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t e ri n g In d o or W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 34
34 COOLING PERFORMANCE DA T A GPC1430H41AB 5MM COILS MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R MANC E D ATA C OOLING OP ER ATION Ou t doo r A m bi en t Te mpera ture 65 75 8 5 95 10 5 115 E nte r i ng I nd oor We t Bulb T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 77 1 MB ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 35
35 COOLING PERFORMANCE DA T A GPC1430H41AB 5MM COILS MOD E L : G P C 1430H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOL ING OP E R AT ION O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t e ri n g In d o or W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 36
36 COOLING PERFORMANCE DA T A GPC1436H41AB 5MM COILS MOD E L : G P C 1436H 41A * EX PAN DE D P ER FO R M ANC E D AT A C OOLI NG OP E R ATION O u t doo r A m bi ent Te mpera ture 65 75 8 5 95 10 5 115 E nte r ing I nd oor We t Bulb T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 77 1 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 37
37 COOLING PERFORMANCE DA T A GPC1436H41AB 5MM COILS MOD E L : G PC1436H41A * EX PA NDE D P ER FO R M AN C E D ATA C OOL ING OPER ATION O ut d o or A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E nt eri ng In d oo r W et B ulb T em p er atu re I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 7 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 38
38 COOLING PERFORMANCE DA T A GPC1442H41AB 5MM COILS MOD E L : G P C 1442H41A * EX PAN DE D P ER F O R M AN C E D ATA C OOLI NG OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t eri n g In d o o r W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 7 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 39
39 COOLING PERFORMANCE DA T A GPC1442H41AB 5MM COILS MOD E L : G P C 1442H41A * EX PAN DE D P ER F O R M ANC E D ATA C OOLIN G OPE R A TION Ou t doo r A mbi e nt Te m pera ture 65 75 8 5 95 10 5 115 E nte r i ng I nd oor Wet Bulb T e m pe r a ture I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 15 9 6 36 77 1 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 40
40 COOLING PERFORMANCE DA T A GPC1448H41AB 5MM COILS MOD E L : G P C 1448H41A B EX PA N DE D P ER FO R MANC E D ATA C OOLI NG OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t eri n g In d o o r W e t B u lb T em p e r at u r e I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 41
41 COOLING PERFORMANCE DA T A GPC1448H41AB 5MM COILS MOD E L : G P C 1448H41A B EX PA N DE D P ER F O R M AN C E D ATA C OOL ING OP ER ATI ON O ut d o o r A m b i en t T em p er atu r e 65 75 8 5 95 10 5 115 E n t e ri n g In d o o r W et B u lb T em p er at u re I D B * A i r f l o w 5 96 36 77 15 9 6 36 77 15 96 36 7 7 15 9 6 3 6 7 7 1 5 96 36 77 ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 42
42 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures incr ...
-
Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A - page 43
WIRING DIAGRAMS 43 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE POWE R S OUR CES MAY B E PRESENT . F AILURE TO DO SO MAY CAUSE PROPERTY DAM AGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. GPC14[24-48]H41AB ...
Do you have a question concerning Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A?
Use the form below
If you did not solve your problem by using a manual Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A, ask a question using the form below. If a user had a similar problem with Goodman Mfg GPC 14 SEER R-410 Package Air Conditioners with R-410A it is likely that he will want to share the way to solve it.