Manual Omron M3

26 pages 1.43 mb
Download

Go to site of 26

Summary
  • Omron M3 - page 1

    Manufacturer OMR ON HEAL THCARE Co ., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAP AN EU-representativ e OMRON HEAL THCARE EUR OPE B.V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omr on-healthcare.com Production facility Site de production Produktionsstätte Stabilimento di produzione Oficina de producción Productief acili ...

  • Omron M3 - page 2

    c d 2 1 L F a b J G H I J K L M N O P T Q R U V W X Y Z S A B C D E F Thank you for purchasing the OMRON M3 Digi tal Automatic Blood Pressur e Monitor . The OMRON M3 is a compact, fully automa tic blood pressure monitor , operating on th e oscillometric principle. It measures your blood pr essure and pulse rate simply and quickly . For comfortable ...

  • Omron M3 - page 3

    1 EN Import ant Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit. Wa rn in g : • Indicates a potentially hazardous situation which, if not avoided, could result in d eath or serious injury . (General Usage) • Always co ...

  • Omron M3 - page 4

    2 Important Safety Information (AC Adapter Usage) • Use only the original AC adapter (optional) designed for this unit . Use of unsupported adapters may damage and/or may be hazardous to the unit. • Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-t ap. • Do not use the AC adapter if the unit or the power cord is ...

  • Omron M3 - page 5

    3 EN 1. Overview Main unit Display O/I ST ART ( ) button Memory button Up/Down ( ) buttons Buzzer and Date/T ime setting ( ) button Air Jack Battery compartment AC adapter jack (for optional AC adapter) Arm cuff Arm cuf f (Medium cuff: arm circumference 22-32cm) Coloured Marker Air tube Air plug Display Systolic blood pressure Diastolic blood press ...

  • Omron M3 - page 6

    4 2. Prep aration 2.1 Inst alling/Replacing the Batteries 1. Remove the battery cover . 2. Insert four “AA” batteries as indicated in the battery comp artment and then re place the battery cover . Notes: • If t he battery low symbol ( ) appears on th e display , turn th e unit off then replace all bat teries at the same time. • The measurem ...

  • Omron M3 - page 7

    5 2. Preparation EN 2.2 Setting the Buzzer/ Date and T ime 1. Press the button. 2. Set the Buzzer . 3. Set the monitor to the corre ct date and time before t aking a measurement for the first time. 4. Press the O/I ST ART button to store the setting. Notes: • If the batteries have been re moved for 30 seconds or more, the date and time setting wi ...

  • Omron M3 - page 8

    6 3. Using the Unit 3.1 Applying the Arm Cuff Remove tight-fitting clothing or tight rolled up sleeve from your up per arm. Do not plac e the cuff over thick clot hes. 1. Insert the air plug into the air jack . 2. Put your arm through the cuff loop. 3. Position the arm correctly . The bottom edge of the cuf f should be 1 to 2 cm above the elbow . M ...

  • Omron M3 - page 9

    7 3. Using the Unit EN 3.2 How to Sit Correctly T o take a measurement, you ne ed to be relaxed and comfort ably seated, under comfortabl e room temperature. No eating , smoking or exercising 30 minutes before taking a m easurement. • Sit on a chair with your feet flat on the floor . • Sit upright with your back straight. --- • The cuff shoul ...

  • Omron M3 - page 10

    8 3. Using the Unit 3.3 T aking a Reading Notes: • T o cancel a measurement, press the O/I ST ART button to turn off the unit and to release the air in the arm cuf f . • Remai n still while taking a measurement. 1. Press the O/I ST ART button. The cuff will start to inflate automatically . The buzzer will sound when me asurement is completed. N ...

  • Omron M3 - page 11

    9 3. Using the Unit EN 2. Remove the arm cuff. 3. Press the O/I ST ART button to turn off the monitor . The monitor auto matically stores the measurement in its memory . It will automatically turn off after five minutes. Important: • Recent research suggests that the foll owing values can be used as a guide to high blood pressure for measu rement ...

  • Omron M3 - page 12

    10 3. Using the Unit 3.4 Using the Memory Function The monitor automatically stores the result up to 60 sets. It can also calcula te an average reading base d on the measurement s from the last three readings t aken within 10 minutes. If there are only two reading s in memory for that period, the average will be based on two readings. If th ere is ...

  • Omron M3 - page 13

    11 3. Using the Unit EN T o delete all the val ues stored in memory When the memory symbol ( ) appears, firs t press the Memory button. Then while holding it down, press the O/I ST ART button simult aneously for about 2-3 seconds. Note: Y ou cannot partially delete the stored reading s. HEM-7200-E(V)_A_ M_main.book 11 ページ 2012年 2? ...

  • Omron M3 - page 14

    12 4. T roubleshooting and Maintenance 4.1 The Icons and Error Messages Error Display Cause Remedy Irregular or weak pulses are detected. Remove the arm cuff. W ait 2-3 minutes and then take another measurement. Repeat the steps in section 3.3. If this error continues to appear , contact your doctor . Movement during measurement. Carefully read and ...

  • Omron M3 - page 15

    13 4. Troubleshooting and Maintenance EN Note: The irregular heartbe at symbol ( ) may also be displayed with error messages. Cuff is under inflated. Carefully read and repeat the steps listed under section 3.3. Movement during measurement. Repeat measurement. Remain still and do not talk during measurement. Refer to section 3.3. Air plug disconnec ...

  • Omron M3 - page 16

    14 4. Troubleshooting and Maintenance 4.2 T r oubleshooting Problem Cause Remedy The reading is extremely low (or high). Arm cuff not applied correctly . Apply the arm cuff correctly . Refer to section 3.1. Movement or talking during measurement. Remain still and do not talk during measurement. Refer to section 3.3. Clothing is interfering with th ...

  • Omron M3 - page 17

    15 4. Troubleshooting and Maintenance EN Nothing happens when you press the buttons. The batteries are empty . Replace the batteries with new ones. Refer to section 2.1. The batteries have been inser ted incorrectly . Insert the batteries with the correct (+/-) polarity . Refer to section 2.1. Other problems. • Press the O/I ST ART button and rep ...

  • Omron M3 - page 18

    16 4. Troubleshooting and Maintenance 4.3 Maintenance T o protect your unit from damage, please ob serve the following: • Do not subject the main unit and the cuff to extreme te mperatures, humidity , moisture or direct sunlight. • Do not fold the cuff or tubing tightly . • Do not inflate the arm cuff over 299 mmHg. • Do not disassemble the ...

  • Omron M3 - page 19

    17 4. Troubleshooting and Maintenance EN 4.4 St or a ge Keep the unit in it s storage case when not in use. 1. Unplug the air tube fr om the air connector . 2. Gently fold the air tu be into the arm cuff. Note: Do not bend the air tube excessively . 3. Place the arm cuff an d main unit in the storage case. Do not stor e the unit in the following si ...

  • Omron M3 - page 20

    18 5. Optional Part s Using the Optional AC Adapter 1. Insert the AC adapter plug into the AC adapter jack on the rear side of the main unit. 2. Plug the AC adapter into an electrical outlet. T o disc onnect the AC adap ter , unplug the AC adapte r from the electrical outlet first and then remove the AC ad apter plug from the main unit. Medium Arm ...

  • Omron M3 - page 21

    19 EN 6. T echnical Dat a Note: Subject to technical modi fication without prior notice. Product Description Digital Automatic Bloo d Pressure Monitor Model OMRON M3 (HEM-7200-E(V )/ HEM-7200-E8(V)) Display LCD Digital Display Measurement Method Oscillometric method Measurement Range Pressure: 0 mmHg t o 299 mmHg Pulse: 40 to 180/min. Accuracy Pres ...

  • Omron M3 - page 22

    20 6. Technical Data • This device fulfils the provisions of EC di rective 93/42/EEC (Medical Device Directive). • This blood pressure monitor is designed according to the European S tandard EN1060, Non- invasive sph ygmomanometers Part 1: Genera l Requirement s and Part 3: Supplementary requirements for electromechanical blood pressure measuri ...

  • Omron M3 - page 23

    21 6. Technical Data EN Import ant informatio n regarding Elec tro Magnetic Comp atibility (EMC) With the increased number of electronic devices such as PC’s and mobile (ce llular) telephones, medical d evices in use may be susceptible to electromagnetic interference fr om other devices. Electromagnetic interference may result in incorrect operat ...

  • Omron M3 - page 24

    22 7. Some Useful Information about Blood Pressure What is Blood Pressure? Blood press ure is a measure of the force of bl ood flowing against the walls of the arteries. Arterial blood pressure is co nstantly changing during the course of the heart’s cycle. The highest pressure in the cycle is called the Systolic Blood Pressure ; the lowest is th ...

  • Omron M3 - page 25

    23 7. Some Useful Inform ation about Blood Pressure EN Why is it a Good Thing to measure Blood Pressure at Home? Many factors such as physical activity , anxiety , or the time of day , can influence your blood pressure . A single measurem ent may not be s uf f icient for an accurate diagnosis. Thus it is best to try and measure yo ur blood pressure ...

  • Omron M3 - page 26

    24 7. Some Useful Inform ation about Blood Pressure Classification of Blood Pressure by the W orld Health Organization The World Health Organiz ation (WHO) and the International Society of Hypertension (ISH) developed the Blood Pressure Classificat ion shown in this figure. This classification is based on the blood pressure values measured on peopl ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron M3 can be divided into several groups. They are, among others:
- Omron technical drawings
- M3 manuals
- Omron product data sheets
- information booklets
- or energy labels Omron M3
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron M3.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron M3, service manual, brief instructions and user manuals Omron M3. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron M3.

A complete manual for the device Omron M3, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron M3 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron M3.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron M3 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron M3, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron M3, that we can find in the current document
3. Tips how to use the basic functions of the device Omron M3 - which should help us in our first steps of using Omron M3
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron M3
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron M3 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron M3?

Use the form below

If you did not solve your problem by using a manual Omron M3, ask a question using the form below. If a user had a similar problem with Omron M3 it is likely that he will want to share the way to solve it.

Copy the text from the picture